Hussmann CoreLink Operation Manual

Hussmann CoreLink Operation Manual

Display manual, case controller
Hide thumbs Also See for CoreLink:

Advertisement

CoreLink
Display Manual
Operation Manual
IMPORTANT
Keep with controller for
future reference!
P/N 3106386_B
July 2020
MANUAL- I/O CORELINK CASE CONTROLLER DISPLAY
Spanish 3106387_A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CoreLink and is the answer not in the manual?

Questions and answers

Moe Hakimi
February 3, 2025

I would like to set the temperature and the manual doesn’t help

User image 67a12f8f2de2c
1 comments:
Mr. Anderson
February 10, 2025

To set the temperature on a Hussmann CoreLink:

1. Use the arrow button to enter the menu.
2. Press the SET button to enter the Configuration Menu.
3. Use the arrows to scroll until the desired parameter (temperature setpoint) is shown.
4. Press SET to view the current setpoint.
5. Press and hold SET for 5 seconds until the setpoint flashes on the screen.
6. Use the arrows to select the new setpoint.
7. Press SET to confirm the new setpoint. The number will flash if done correctly.

This answer is automatically generated

Summary of Contents for Hussmann CoreLink

  • Page 1 CoreLink ™ Display Manual Operation Manual IMPORTANT Keep with controller for future reference! P/N 3106386_B July 2020 MANUAL- I/O CORELINK CASE CONTROLLER DISPLAY Spanish 3106387_A...
  • Page 2: Power-Up Sequence

    First time power up displays: noL noL Indicates “no communication” between the display and CoreLink noL Displays until the CoreLink starts to communicate with the display a few seconds after power up. P/N 3106386_B U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM...
  • Page 3: Display Menu

    • Use arrows to enter a new override parameter value. Press to accept value. • New value will flash once accepted • Press to exit Override Menu CoreLink Case Display HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. ™...
  • Page 4: Configuration Menu

    Parameter Menu. CoreLink Display Usage Examples How to change a setpoint: From the Hussmann display, superheat and refrigeration setpoints can be set. 1. If not at the main top-level menu, press together repeatedly until reaching the main top-level menu.
  • Page 5 How to stop a defrost: To stop a defrost and return the case to refrigeration mode, repeat steps 1-9 above, but select the menu at Step 5 to send a Defrost Stop (dtr) command to the CoreLink. CoreLink Case Display HUSSMANN CORPORATION •...
  • Page 6 (The new address will flash on the screen when this step is complete). BACnet 7. To edit the CoreLink’s BACnet address, repeat Steps 4, 5, and 6, but select bAc from the menu at Step 4. How to reboot the controller From the display, you can reboot the controller with a simultaneously two button push 1.

Table of Contents