Dental unit
CHIRANA CHEESE L
INSTRUCTIONS FOR USE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHEESE L and is the answer not in the manual?

Questions and answers

Александр Леонов
May 26, 2025

Не реагирует кресло на кнопку (1) положение стула вниз не производится . Клавиша выдает звуки, кресло не опускается вниз.

1 comments:
Mr. Anderson
May 26, 2025

If the Chirana Medical CHEESE L chair does not respond to the button and does not lower, first ensure nothing is in the path of the chair or backrest. Then try pressing and holding the button for controlled downward movement. If the chair still does not move, check if the Safety STOP button was pressed, as it stops all chair movement. Also, ensure the chair is not blocked by the spittoon bowl if it is rotated over the chair.

This answer is automatically generated

Summary of Contents for Chirana Medical CHEESE L

  • Page 1 Dental unit CHIRANA CHEESE L INSTRUCTIONS FOR USE...
  • Page 2 INSTRUCTIONS FOR USE - CHIRANA CHEESE L CHIRANA Medical a.s., Stará Turá Nám. Dr. A. Schweitzera 194 916 01 Stará Turá, P.O.Box 57 SLOVAK REPUBLIC Tel. : +421 32 775 2323 Fax.: +421 32 775 3221 +421 918 714 000...
  • Page 3: Table Of Contents

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L CONTENTS : Page Operating warnings ......................5 1.1. Symbols ........................5 1.2. Target group ........................ 5 1.3. Service ......................... 5 1.4. Operating book ......................5 1.5. Guarantee conditions ....................5 Purpose and use ........................6 Assembly and instalation ....................
  • Page 4 Electromagnetic radiation ..................34 15.2. Resistance against the electromagnetic interference ..........34 15.3. Recommended protective distances between the portable and mobile high frequency communication devices and the dental unit CHIRANA CHEESE L ....36 Serial. No. S13 02800 54/pol. 1...
  • Page 5: Operating Warnings

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Operating warnings 1.1. Symbols This symbol draws in the instructions indicated warnings that require special attention. Before the first use of this product, familiarize yourself with all the ATTENTION warnings described in this manual! This symbol draws in the instructions indicated other important warnings 1.2.
  • Page 6: Purpose And Use

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Purpose and use Dental unit CHIRANA CHEESE L is intended only for use in dentistry. It can operate only by qualified medical personnel. The set is designed into the non-explosive area. ATTENTION Assembly and instalation Assembly and installation of the dental unit CHIRANA CHEESE L can perform a service technician of CHIRANA Medical, Inc.
  • Page 7: Dentist Table

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Dentist table on pantographic arm Assistant ´s table Spittoon block Column of arms Foot control Head lamp Armchair Plate Mobile dentist table Some parts of the dental unit are optional by customers and therefore may differ from the images shown.
  • Page 8: Assistant Table

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 4.1.2. Assistant table Assistant table has two versions: assistant table for 1-2 tools and table for 1-4 tools. Assistant table can be attached to the swivel arm, the double swivel arm, or on the height adjustable swivel arm.
  • Page 9: Pilar Of Arms

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 1. Cover left 2. Cover right 3. Cup filling with rinsing bowl 4. Spittoon bowl 5. Bottle with clean water for cooling tools 6. Bottle of disinfectant for the disinfection of waterways of...
  • Page 10: Foot Control

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 4.1.5. Foot control Ý Foot control pivoted Foot switch without buttons Foot switch with buttons 1 push together Foot control multifunctional pedal Foot control multifunctional pivoted 1. Starting 4. Chair control 2. Blowing throught the instrument 5.
  • Page 11: Head Lamp

    WARNING For charging, use only wiring which is delivered as an accessory of the foot controller. WARNING Hereby, CHIRANA Medical a.s. declares that the radio equipment type is in CHIRANA CHEESE L compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.chirana.sk/certification...
  • Page 12: Chair

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 4.1.7. Chair 1. Seat 2. Backrest 3. Arm rest 4. Head backrest 5. The locking knob back head 6. Locking lever-back head 7. Programming button 8. Lock lever of the backrest of the head 9.
  • Page 13: Dimensions Of Dental Unit

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 4.2. Dimensions of dental unit * data for the chair SK1-08 Serial. No. S13 02800 54/pol. 1...
  • Page 14: Production Label

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 4.3. Production label CHIRANA CHEESE L Producer Vintage The device must not be disposed of with Serial number household waste Working hours of the chair 30sec. IPX1C Degree of protection Pause time of chair 4.5 min.
  • Page 15: Basic Equpiment

    ATTENTION - Use only spare parts from the company CHIRANA Medical, Inc.. Additional equipment Additional equipment supplied with the device is included in the Packing list as part of the accessories that are supplied with the device to special order.
  • Page 16: Switching The Light

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L After switching dental unit for 4 seconds are tested circuits of the set. First are tested circuits of the chair. After the successful test, you will hear an acoustic signal. Testing continues by testing the dentist table. Part of the test is testing the keyboard of the dentist, resulting by illumination of all display elements for 2 sec.
  • Page 17: The Handling With A Chair

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Wheel of mechanical brake Button of pneumatic brake Setting the height of mobile dentist´s table: Hinge of tool hoses To enhance the position of the dentist's table To reduce the table position of the dentist press the press the button with your finger.
  • Page 18: The Manual Mode

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Adjusting the seat of the head and the right arm-rests is done mechanically. According to the version of the chair is an adjusting height of the backrest ensured by the locking wheel of the back of the head or by the locking lever of the head of the backrest, see fig.
  • Page 19: Setting Of The Programming Positions Of The Chair

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L U3 – (user3) user 3 U4 – (user4) user 4 (two horizontal lines) all movements of the chair are blocked All the movements of the chair are blocked for the safety reasons, while working with the tools located on the dentist´s tray of the dental unit.
  • Page 20: Basic Functions

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Dentist keyboard Assistant keyboard negatocope indicative scale Magnetic holder of X-ray images 8.3.1. Basic functions Turn on / off the instrument for cooling If lights the signalization, is cooling on. Cooling the instrument can be turned on and off using a foot controller.
  • Page 21 INSTRUCTIONS FOR USE - CHIRANA CHEESE L Increasing the set value Programming button Parameters that can be programmed are described in the "Programming". Enable / disable negatoscope If negatoscope is on for more than 5 min., it will automatically turns off.
  • Page 22: Additional Functions

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 8.3.2. Additional functions Measurement of working time of rotary instruments with indication for instrument treatment preparations SMIOIL. Function provides real-time measurement of work of rotating tool and after the time when it is necessary to treat the instrument (20 min work of tool), this condition is indicated by a flashing indication on the indicator scale.
  • Page 23: Controlling Tools On The Dentist Table

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 3 – 20s Set time of cup filling Press and hold the cup filling for the time, which we want to program. By releasing of button , will sound an acoustic signal and a new cup filling time is written into memory. The minimum time of setting is 3 seconds.
  • Page 24: Micromotor

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L The mechanical button for regulation of the cooling water 2. Catcher of oil In the basic equipment is a common regulator for adjusting the amount of water in all the instruments (except a multifunctional syringe). Depending on the equipment, the set may comprise a single mechanical controls the amount of water for each instrument separately.
  • Page 25: Ultrasonic Dental Scaler

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Giromatic Function at which the instrument of the micromotor handpiece cyclically turning right and left. The angle of rotation (oscillation) instrument is adjusted using the + and - in the range of ± 60 ° to ± 100 °.
  • Page 26: Polymerization Lamp

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 8.4.6. Polymerization lamp To run the activity of the polymerization lamp press the button on the body of lamp. To end the activity press the button for the second time. Different types supplied polymerization lamp have different lighting modes.
  • Page 27: Control The Instruments On The Dentist Table

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L During the disinfecting cycle, the normal operation of the instruments is blocked. 8.5. Control the instruments on the dentist table 8.5.1. Saliva ejector It is activated automatically after removing the terminals of the holder. After inserting terminal to holder the activity of the ejector stops.
  • Page 28: The Control Button Of Spittoon Valve Dürr Msbv

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L 8.8.1. The control button of spittoon valve Dürr MSBV 1. A button for starting the auto-cleaning. Start twice a day The spittoon valve Dürr MSBV ensures extraction of waste from the spittoon bowl sets involved in the central wet vacuuming.
  • Page 29: Description Of Acoustic Warnings

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Before bottle filling depressurize the cylinder bleeder valve switching towards the bottles. Switch valve back to pull them up by screwing the bottles into their original location. ATTENTION Bottles with clean water and disinfectant are bolted to the spittoon block. For the withdrawal of the bottle, turn the bottle left.
  • Page 30: Product Maintenance

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L acoustic signal symptoms and elimination note Wireless foot Signalling the low battery status Frequency of the acoustic signalling is controller emits of the foot controller. escalating depending on the battery three acoustic Connect the foot controller to the discharge.
  • Page 31 INSTRUCTIONS FOR USE - CHIRANA CHEESE L Cleaning the filter of suction hoses: 1(5) 1. Press release cover of filters 2. Select cover of filters 3. Remove and clean the filter 4. Insert the filter back 5. Insert the cover of filters and gently push Cleaning of the spittoon valve filter Dürr MSBV :...
  • Page 32: Maintenace By Service Technician

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Chemicals must be collected only on the tray of tray table. Accidental instillation of chemical agents such. Trikresol, Chlumský solution and other aggressive substances on the painted part of the device, the surface should be wiped up immediately by wipe soaked in water.
  • Page 33: Safety Technical Controls

    INSTRUCTIONS FOR USE - CHIRANA CHEESE L Use only the disinfectants for the waterways of dental equipment. Follow the instructions and expiration date printed on the label of the bottle with WARNING the disinfectant. Sterilized in autoclaves can be: - Nozzle syringes...
  • Page 34: Guidance And Declaration Of The Producer To The Electromagnetic Compatibility

    30 cm (12 inches) from any part of the dental unit CHIRANA CHEESE L including the cable to the foot controller. Otherwise, the function of dental unit may be impaired.
  • Page 35 INSTRUCTIONS FOR USE - CHIRANA CHEESE L Testing level of the Electromagnetic Test of resistance resistance according to Complying level environment EN 60601 ±2kV for the feeding line ±2kV for the feeding line Fast electric Quality of the power ±1kV for the input ±1kV for the input/output...
  • Page 36: Recommended Protective Distances Between The Portable And Mobile High Frequency Communication Devices And The Dental Unit Chirana Cheese L

    If the measured field intensity in the site where the dental unit CHIRANA CHEESE L will be used exceeds the above mentioned complying level, then the dental unit CHIRANA CHEESE L should be observed to confirm its operation in accordance with the abnormal characteristics, it may be necessary to perform intended purpose.
  • Page 37 INSTRUCTIONS FOR USE - CHIRANA CHEESE L For the transmitters which maximum output power is not described in the table, may be recommended the protective distance d in meters (m) specified by using the equation suitable for the transmitter frequency, where P is the rated maximum output power of the transmitter in Watts (W) according to the data of the transmitter manufacturer.