WITA Fixed Setpoint Controller SM WR FR
INSTALLATIONSHANDBUCH
D
FESTWERTREGLER
SEITE 2–18
INSTALLATION GUIDE SETPOINT
GB
VALUE CONTROLLER
PAGE 20–36
INSTALLATIONSHANDBUCH
PL
FESTWERTREGLER
STRONA 38–54
|
|
www.wita.de

Advertisement

Table of Contents
loading

Summary of Contents for WITA SM WR FR

  • Page 1 ONLY ORIGINAL WITH THE DIAMOND® WITA Fixed Setpoint Controller SM WR FR INSTALLATIONSHANDBUCH FESTWERTREGLER SEITE 2–18 INSTALLATION GUIDE SETPOINT VALUE CONTROLLER PAGE 20–36 INSTALLATIONSHANDBUCH FESTWERTREGLER STRONA 38–54 www.wita.de...
  • Page 2: Table Of Contents

    Ads in case of failure..........................29 Manual mode.............................30 Assembly of the controller SM WR FR on heating mixer .............30 Mounting of the fixed setpoint controller SM WR FR onto different mixing valves ....30 Electrical installation..........................31 Safety instructions before and for commissioning ...............31 For visible damage ..........................31...
  • Page 3: Declaration Of Conformity

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR EC Declaration of Conformity Name of the issuer: WITA-Wilhelm Taake GmbH Pumpen-, Armaturen- und Regeltechnik Display HE Pumpen Böllingshöfen 85 D-32549 Bad Oeynhausen Subject of the declaration: Fixed Setpoint Controller Type:...
  • Page 4: Safety Instructions

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 2 Safety Instructions 2.1 General These installation and operating instructions are a part of the product, and contain basic information that must be observed during installation, operation and maintenance. For this reason, the installer and specialist personnel or operators must read these instructions prior to set-up.
  • Page 5: Personnel Qualification

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR This symbol indicates useful information Note for handling the product. It indicates potential difficulties and aims to ensure safe operation. Signs attached directly on the product, such as: • direction of rotation arrow •...
  • Page 6: Dangers Of Not Observance Of The Safety Instructions

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 2.4 Danger of not observing safety instructions Not observing the safety information can endanger persons, the environment and the system. Not observing the safety instructions shall result in the loss of any and all claims to warranty.
  • Page 7: Safety Instructions For Installation And Maintenance

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR • Observe the instructions in local or general regulations (e.g. IEC, VDE, etc.), and those of the local energy supplier. • In the event of hazards arising from the system due to Display HE Pumpen contact with hot or cold parts, these parts must be fitted...
  • Page 8: Unpermitted Operation

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR liability for any consequences resulting from the use of other parts. 2.9 Unpermitted operation If the pump is disconnected from the power supply, wait at least 1 minute before reactivating. Otherwise, the pump's in- rush current limit has no effect, which can lead to functional errors or damage to any connected heating controller.
  • Page 9: Intended Use

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 4 Intended Use The WITA fixed setpoint controller SM WR FR is a constant or fixed setpoint temperature controller for heating or cooling systems. His field of application is, Display HE Pumpen the return flow, the control of surface heating, or where constant temperatures...
  • Page 10: Operating Elements Of The Fixed Value Controller Sm Wr Fr

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR Operating elements of the fixed value controller SM WR FR 1. Graphic display 2. Button (Help / User Guide). 3. Button for manual operation. 4. Removable button for manual operation. 5. Button (return) 6.
  • Page 11: User Guide

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR User Guide Button (2) Help / User Guide Display HE Pumpen Basic display It serves as information for the operation see point see point of the settings for 7.2-2 7.2-1 • set temperature adjustment •...
  • Page 12: Manual Mode

    6 MAssembly of the controller SM WR FR on heating mixer Mounting the fixed setpoint controller SM WR FR to different mixers can only be made with manufacturer-specific mounting kits. When selecting the drive, please observe because of the torque the data sheet of the mixer while mounting with manufacturer-specific mounting kits, the enclosed installation...
  • Page 13: Electrical Installation

    Due to the preassembled main connection cable and the preassembled Note temperature sensor the SM WR FR is immediately ready for operation. The temperature sensor was installed for flow temperature control at the flow line of the Display HE Pumpen heating or cooling circuit.
  • Page 14: Selection And Adjustment Of The Set Point Temperature

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 7.2.2 Selection and setting of the set point temperature The adjustment can be done by the but- tons 1 ° increments and confirmed with the . The change will be immediately...
  • Page 15: Selection And Adjustment Of The Minimum, Maximum And Setpoint Temperature

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 7.3.2 Selection and adjustment of the minimum, maximum and set point temperatures for the application Heat. Setting range of temperatures for min. temperature = 10 ° - 70 ° setting temperature = min.
  • Page 16: Selection And Setting Of The Minimum, Maximum And Setpoint Temperature During Application Cooling

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 7.3.3 Selection and adjustment of the minimum, maximum and set point temperatures for the application Cool. Setting range of temperatures for min. temperature = 5 ° - 30 ° setting temperature = min.
  • Page 17: Commissioning Of The Wita Fixed Setpoint Controller Sm Wr Fr

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 8 Commissioning of the WITA Fixed Setpoint Controller SM WR FR When the controller is connected to the mains for the first time, the display shows the type of the controller, the program version and the LOGO are displayed.
  • Page 18: Sensor Features

    Operating instrutions WITA Fixed Setpoint Controller SM WR FR 9 Sensor The temperature sensor is preassembled on the fixed setpoint value controller Note with flow temperature control, it is installed on the flow line of the heating circuit. In the return temperature control on the boiler return.
  • Page 19 Notes...