PCE Health and Fitness CIC Series User Manual

Colour viewing box

Advertisement

Quick Links

User Manual
PCE-CIC Series Colour Viewing Box
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 25 August 2020
v1.0
© PCE Instruments

Advertisement

Table of Contents
loading

Summary of Contents for PCE Health and Fitness CIC Series

  • Page 1 User Manual PCE-CIC Series Colour Viewing Box User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com Last change: 25 August 2020 v1.0 © PCE Instruments...
  • Page 2: Table Of Contents

    Contents Introduction ................... 1 Safety notes ................... 1 Specifications ..................2 Delivery scope ..................2 Light sources used ................3 Structure ....................3 Device description ................5 PCE-CIC 5 ........................5 PCE-CIC 10 ........................6 PCE-CIC 11 ........................7 Operation notes ..................8 Test report* ....................
  • Page 3: Introduction

    Introduction Thank you for purchasing a colour viewing box from PCE Instruments. A colour viewing box is used wherever products must have the same colour properties during production. Thus a colour viewing box contributes to quality control. The colour viewing box is a simulation instrument which, by means of different types of light, is able to display certain situations in order to analyse the colour characteristics of individual samples.
  • Page 4: Specifications

    • Colour viewing boxes are not designed for permanent lighting. • Used fluorescent lamps must be disposed of in accordance with the current disposal directive and must not be disposed of as normal household waste. • Non-observance of the safety notes can cause damage to the device and injuries to the user.
  • Page 5: Light Sources Used

    Light sources used Standard Scope of application Colour Watt Type light temperature Daylight simulation for SYLVANIA 6500 Kelvin industry for colour evaluation F20T12/D65 PHILIPS Department store, warehouse TL84 / F11 4100 Kelvin TLD 18W/33- and office in Europe Fluorescent light (warm white) PHILIPS TL83 / U30 3000 Kelvin...
  • Page 6 1. Remove the base plate ➀ and place it with the set-up side (feet / felt) on the table. 2. Screw the rear panel ➁ onto the base plate. The MATT painted side is the inner side. 3. Now the side parts ➂ must be screwed to the bottom wall ➀ and the rear wall ➁. The MATT painted side is the inner side.
  • Page 7: Device Description

    Device description PCE-CIC 5 On/off LED LED F light LED D65 light LED TL84 light LED UV light On/off key F light key D65 light key TL84 light key 10. UV light key 11. Clear key 12. LC display © PCE Instruments...
  • Page 8 PCE-CIC 10 On/off LED LED D50 light LED D65 light LED TL84 light LED UV light LED CWF light LED TL83 light On/off key D50 light key 10. D65 light key 11. TL84 light key 12. UV light key 13. CWF light key 14.
  • Page 9 PCE-CIC 11 On/off LED LED F light LED D85 light LED TL84 light LED UV light LED CWF light LED TL83 / U 30 light On/off key F light key 10. D85 light key 11. TL84 light key 12. UV light key 13.
  • Page 10: Operation Notes

    Operation notes The observer should wear a neutral (achromatic) colour for the evaluation of the samples to avoid reflections and other influences. The observer must be examined and selected by an appropriate method to ensure normal colour vision and normal ability to distinguish colours. Press the on/off key to turn on the colour viewing box.
  • Page 11: Test Report

    Test report* The test report should contain at least the following information: (a) All details necessary for the identification of the tested coating material; (b) a reference to this international standard (ISO 3668); (c) details of additional information referred to in annex A; (d) a reference to the international or national standard, product specification or other document containing the information referred to in (c);...
  • Page 12: Bulb Replacement

    Bulb replacement Before changing the lamp, disconnect the cold-device plug from the power supply. Wait until the lamps have cooled down before replacing them. The illuminants have a marking and must be re-inserted in the place provided for this purpose. The illuminants must always be completely replaced for the respective light sources in order to ensure consistent quality based on the number of operating hours.
  • Page 13: Warranty

    Lamps are not household waste and must be disposed of in accordance with the applicable disposal guidelines. After cleaning up, wash your hands thoroughly and air the room for some time. Warranty You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms.
  • Page 14 PCE Instruments contact information Germany France Spain PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel.

This manual is also suitable for:

Cic 5Cic 10Cic 11

Table of Contents