  • Page 1 Operation manual for EcoLite Charge Points...
  • Page 2 Thank you for purchasing a Viridian EV charge point. This guide is intended to instruct in the proper use of all models of Viridian Charging stations. Installation of this equipment should only be carried out by a fully qualified professional. Viridian EV accepts no responsibility for damage caused by improperly installed equipment.
  • Page 3 Iss 1 - Feb 2018 Page 3 of 9 WARNING The charging station is designed for electric vehicle (EV) charging only. It is designed to only allow the flow of electricity once an EV is connected and correct communication is established. Any tampering of the Charging station to allow the flow of electricity at any times other that this will present a risk of electric shock.
  • Page 4 C - An electric vehicle is connected and charging BLUE D - An electric vehicle is connected but ventilation is required. This mode is not supported by Viridian EV charge points so will not charge. Fault detected, charging is not allowed. See troubleshooting or seek (Pulsing) technical support.
  • Page 5 Resetting the trip switch Viridian EV charge points are, by default, fitted with electrical protection. It is possible if an earthing problem or another fault occurs this protection will trip out. To reset the trip switch and begin charging again use the key provided to remove the small access panel on the front (Feature 1 indicated above) and throw the switch on the electrical protection.
  • Page 6 Iss 1 - Feb 2018 Page 6 of 9 Any repair work should only be carried out by a suitably qualified individual. It is recommended that you test the function of the fitted electrical protection once a month by removing the access panel and pressing the test button. If the RCBO or equivalent protection fails its function test you should immediately stop using the charging station and contact your installer for further assistance.
  • Page 7: Warranty

    Page 7 of 9 Warranty Viridian EV provides a 3 year full parts and labour warranty for operational failure of the charging station. This is the same for charging stations installed under the OLEV EVHS & WCS. In the event of any operational issues with your Viridian EV charging station please contact the electrician responsible for the installation of the charging station and a solution will be put into motion.
  • Page 8: Troubleshooting Guide

    Iss 1 - Feb 2018 Page 8 of 9 Trouble Shooting Guide Problem Solution EV not charging Check the - Status LEDs not lit Check power to the unit Has the main feed from the consumer status unit tripped Has the internal RCBO tripped - Text &...