INSTALLATION AND OPERATING INSTRUCTIONS
I
INSTALLATION AND OPERATING INSTRUCTIONS
Viron Range
Inverter Heat Pumps
VIRON RANGE
INVERTER HEAT PUMPS
Installation & Instruction manual
The appliance is not intended for use by young children
3/08/2017

Advertisement

loading

Summary of Contents for fluidra ASTRALPOOL Viron Series

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS Viron Range Inverter Heat Pumps VIRON RANGE INVERTER HEAT PUMPS Installation & Instruction manual The appliance is not intended for use by young children 3/08/2017...
  • Page 3: Table Of Contents

    CONTENTS 1. Preface 2. Specifications 2.1 Performance Data of Swimming Pool Heat Pump Unit 2.2 Dimensions for Swimming Pool Heat Pump Unit 3. Installation and Connection Installation illustration Swimming Pool Heat Pumps Location 3.3 How Close to Your Pool? 3.4 Swimming Pool Heat Pumps Plumbing 3.5 Swimming Pool Heat Pumps Electrical Wiring 3.6 Initial Start-up of the Unit 4.
  • Page 4 1. PREFACE In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
  • Page 5 1. PREFACE This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack experience knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 1. PREFACE Caution & Warning 1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer. for Europe market 2. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 7: Performance Data Of Swimming Pool Heat Pump Unit

    2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R32 UNIT 78572 78573 Heating capacity 2.15~9 2.85~12 (27/24.3 Btu/h 7310~30600 9690~40800 Heating Power Input 0.16~1.6 0.21~2.12 13.44~5.63 13.57~5.66 Heating capacity 1.75~7.4 2.25~9.7 (15/12 Btu/h 5950~25160 7650~32980 Heating Power Input 0.25~1.6 0.32~2.08...
  • Page 8 2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R32 UNIT 78574 78575 Heating capacity 3.77~17 4.6~19.5 (27/24.3 Btu/h 12818~57800 15640~66300 Heating Power Input 0.3~3.02 0.37~3.94 12.57~5.63 12.43~4.95 Heating capacity 2.92~12.4 3.84~15.4 (15/12 Btu/h 9928~42160 13056~52360 Heating Power Input 0.44~2.86 0.6~3.81...
  • Page 9 2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R32 UNIT 78576 78577 Heating capacity 5.7~24.2 6.7~28.3 (27/24.3 Btu/h 19380~82280 22780~96220 Heating Power Input 0.46~4.8 0.54~5.57 12.39~5.04 12.41~5.08 Heating capacity 4.68~19.9 5.46~23.3 (15/12 Btu/h 15912~67660 18564~79220 Heating Power Input 0.72~4.74 0.83~5.49...
  • Page 10: Dimensions For Swimming Pool Heat Pump Unit

    2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit UNIT: 78572/78573 unit mm 1046 Water outlet 48.3 Water inlet 48.3 UNIT: 78574/78575 unit mm 1161 Water outlet 48.3 Water inlet 48.3...
  • Page 11 2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit UNIT: 78576/78577 unit mm 1161 Water outlet 48.3 Water inlet 48.3...
  • Page 12: Installation And Connection

    INSTALLATION AND CONNECTION 3.1 Installation illustration Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer. Attention: Please follow these steps when using for the first time 1.Open valve and charge water.
  • Page 13 INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh Air - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier.
  • Page 14 3.INSTALLATION AND CONNECTION 3.4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass(please set the flow rate according to the nameplate). The water pressure drop is less than 10kPa at max. Flow rate. Since there is no residual heat or flame Temperatures, The unit does not need copper heat sink piping.
  • Page 15: Initial Startup Of The Unit

    3.INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit.
  • Page 16 Operationanduse Color screen wire controller interface introduction 4.1.1Maininterface ⑨ 09 DEC 2017 ⑧ ① ② ③ ④ ⑤ ⑥ ⑦ 4.1.2 Button Description The button function Name ① ON/OFF Press to start /shut off the unit ② Click to lock the screen ,Input "22" to unlock the LOCK screen by press the "lock button"...
  • Page 17 4.Operationanduse 4.2 Color screen wire controller function introduction Booting and shutdown 4.2.1 As shown in figure 1.1: ① In shutdown status, click then the unit will be booted ① In booting status, click then the unit will be shut down. Mode switch and target temperature Setting 4.2.2 2.2 1 Mode switch...
  • Page 18 4.Operationanduse 4.2.3 Clock setting In the main interface, click on the clock Settings button, interface displays as follows: ① ② The operation of time setting 2.3.1 ① Click on the time Settings button , interface displays as follows: Click the value to set time directly, the click confirm button to save the Settings.
  • Page 19 4.Operationanduse The operation of timing setting 2.3.2 ② Click the timing set button to enter timing setinterface. ① ② ③ ④ Name Button color Button function ① Start: green Timing start Click this button to start or end End: gray timing start setting function button ②...
  • Page 20 4.Operationanduse 4.2.4 Silent setting and silent timing setting Click the silent setting button ,and the interface displays as follows: 09 DEC 2017 ① ② The silent button 2.4.1 ① Click the silent button , the unit will enter the silent mode, and interface displays as follows: 09 DEC 2017 ①...
  • Page 21 4.Operationanduse Timing silent function setting 2.4.2 ② Click timing silent button , and interface displays as follows: ① ② ③ ④ Function Name Color ① Used: red Timing silent off Click to use or unuse timing Unused:gray off function ② Use:green Click to use or unuse timing Timing silent on...
  • Page 22 4.Operationanduse 4.2.5 History of the fault In the main interface click fault display key, interface displays as follows: Fault time day - month - year The fault name Fault code hour:min If no failure, main interface displays static " " When fault occurs,the fault icon will flash between the "...
  • Page 23 4.Operationanduse 4.2.7 Temperature curve In the main interface, click the curve display button, interface displays as follows: 2.7.1 Temperature recording curve is as follows: 2.7.2 Comp.Frequency curve Temperature curve automatically updates every one hour, and the curve record can be stored for 60 days; Start from the latest curve saved time, if power is off and curve data collecting time is less than one hour, the data in this period will not be saved;...
  • Page 24: Operation And Use

    4.OPERATION AND USE 4.3 Parameter list and breakdown table (1) Electronic control fault table Can be judged according to the remote controller failure code and troubleshooting Fault Protect/fault Reason Elimination methods display Standby Normal boot The temp. Sensor is broken Check or change the temp.
  • Page 25 4.OPERATION AND USE 1. Motor is in locked-rotor state Change a new fan motor 2.The wire connection between Check the wire connection and make sure Fan Motor2 Fault F032 DC-fan motor module and fan they are in good contact motor is in bad contact Communication Fault Speed control module and main E081...
  • Page 26 4.OPERATION AND USE (2) Parameter list Meaning Default Remarks Adjustable Adjustable Adjustable 4.4 Interface drawin (1) Wire control interface diagram and definition Sign Meaning 12V power + No use No use 485A 485B GND(power-) (2) Controller interface diagram and definition AC-N OUT5 OUT4 OUT3 OUT2 AC-L OUT1 FUSE...
  • Page 27 4.OPERATION AND USE Main board of the input and output interface instructions below Number Sign Meaning OUT1 Compressor ( output 220-230VAC OUT2 Water pump ( output 220-230VAC OUT3 4-way valve ( output 220-230VAC OUT4 High speed of fan ( output 220-230VAC OUT5 Low speed of fan (output 220-230VAC AC-L...
  • Page 28 4.OPERATION AND USE Controller interface diagram and definition...
  • Page 29 4.OPERATION AND USE Controller interface diagram and definition...
  • Page 30 4.OPERATION AND USE Main board of the input and output interface instructions below Number Sign Meaning Color line controller communication...
  • Page 31 5. MAINTENANCE AND INSPECTION Check the water s upply devic e and the release often. You should av oi d the condition of no water or air entering into sy stem, as this will i nfluence unit's perf or manc e and reliabil it y. You should clear the pool/ spa fi lter regularl y to av oid damage to the un it as a result of the dirty of c logged f ilter.
  • Page 32 5. MAINTENANCE AND INSPECTION No ignition sources No person carry ing out work in relation to a refr igeration sy stem whic h inv olves ex posing any pipe work that contains or has contained f lammable refrigerant s hal l use any sourc es of i gni tion in suc h a manner that it may l ead to the risk of f ire or ex plosion.
  • Page 33 5. MAINTENANCE AND INSPECTION Repairs to sealed components 1) During repairs to s ealed c omponents , all elec tri cal supplies shall be di sc onnec ted f rom the equipment being work ed upon pr ior to any removal of sealed covers , etc. If it is abs olutel y necess ary to hav e an electric al supply to equi pm ent during s ervi cing, then a permanently operating form of leak detec ti on s hal l be loc ated at the m os t c rit ical point to warn of a potentially haz ardous situation.
  • Page 34 5. MAINTENANCE AND INSPECTION Remov al and evac uation When break ing i nto the refrigerant c irc ui t to m ak e repai rs or for any other purpos e conv entional procedures s hall be us ed. Howev er, it is important that bes t prac ti ce is followed sinc e f lammabil ity is a consi deration.
  • Page 35 5. MAINTENANCE AND INSPECTION Dec om miss ioning Before carr ying out this procedure, it is essential that the technic ian i s completely famili ar with the equipment and all its detail . I t is recommended good practice that all refrigerants are recovered safely.
  • Page 36: Cable Specification

    6.APPENDIX 6.1 Cable specification (1) Single phase unit Nameplate Creepage protector Signal line maximum Phase line Earth line current No more 1.5mm 1.5mm than 10A 30mA less than 0.1 sec 2.5mm 2.5mm 10~16A 30mA less than 0.1 sec 16 ~25A 30mA less than 0.1 sec 25 ~32A 30mA less than 0.1 sec...
  • Page 37 6.APPENDIX 6.2 Comparison table of refrigerant saturation temperature Pressure (MPa ) Temperature -51.3 (R410A)( ) Temperature -52.5 29.5 33.3 38.7 (R32)( ) Pressure (MPa ) Temperature (R410A)( ) Temperature 46.5 49.5 53.5 67.5 72.5 77.4 (R32)( )
  • Page 38 Note:...