ROSSMA IIOT-AMS Operation Manual
Hide thumbs Also See for IIOT-AMS:

Advertisement

Quick Links

MEASURING AND SWITCHING DEVICE
ROSSMA IIOT-AMS Smoke Detector
OPERATION MANUAL
ROSSMA IIOT-AMS Smoke Detector is used for autonomous wireless operation of the smoke
sensor ИП212-50М manufactured by LLC "EDGE" and is designed to monitor and record the
change in the state of the smoke sensor, as well as to transmit an alarm event when switching
to "Fire" mode in LoRaWAN or NBiOT network.
www.rossma.ru

Advertisement

Table of Contents
loading

Summary of Contents for ROSSMA IIOT-AMS

  • Page 1 ROSSMA IIOT-AMS Smoke Detector OPERATION MANUAL ROSSMA IIOT-AMS Smoke Detector is used for autonomous wireless operation of the smoke sensor ИП212-50М manufactured by LLC "EDGE" and is designed to monitor and record the change in the state of the smoke sensor, as well as to transmit an alarm event when switching to "Fire"...
  • Page 2 ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL DATA ON THE DOCUMENT Title Measuring and switching device ROSSMA IIOT-AMS Smoke Detector Document type Operation manual Document code MAN-RIASD-01 Last revision number and date 04.09.2018 THIS DOCUMENT IS VALID FOR THE FOLLOWING DEVICES...
  • Page 3: Table Of Contents

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL CONTENTS INTRODUCTION ..............................3 1. DESCRIPTION AND OPERATION PRINCIPLE ....................4 DESCRIPTION ................................4 DATA COLLECTION AND TRANSMISSION ALGORITHM ..................... 4 FUNCTIONALITY ................................ 4 MARKING .................................. 5 DATA ON CERTIFICATION ............................5 ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ ......................7 3.
  • Page 4: Introduction

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL INTRODUCTION This manual applies to autonomous measuring and switching device ROSSMA IIOT-AMS Smoke Detector manufactured by "ROSSMA" LLC and defines installation and connection procedure, as well as control commands and functional description. The manual is intended for specialists familiar with the installation rules in the field of various electronic and electrical equipment.
  • Page 5: Description And Operation Principle

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL 1. 1. DESCRIPTION AND OPERATION PRINCIPLE DESCRIPTION The device is built into the housing of the smoke sensor ИП212-50М manufactured by LLC "BORDER" (http://td.rubezh.ru/products/detail.php?ID=1694) and is designed to record the change of smoke sensor state and to initialize the communication session with the transmission of the alarm event when switching to the "Fire"...
  • Page 6: Marking

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL • Configurable communication period from 1 minute and more (configured remotely in LoRaWAN network). The default value is 1 time a day; • Support for sending confirmation packages (configurable) • Frequency plan: EU-868\RU-868 (to switch remotely in LoRaWAN network). Default is RU- 868;...
  • Page 7 ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL Certificate of compliance No. РОСС RU.0001.21AB90 Declaration ЕАЭС N RU Д-RU.АБ93.B.08697 on Compliance with the Technical Regulation Requirements of the Customs Union ТР ТС 020/2011 "Electromagnetic Compatibility of Technical Means" Meets industrial safety requirements.
  • Page 8: Технические Характеристики

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL 2. ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ THE MAIN Connection interface To outputs on the ИП212-50М board Operation temperature range -10…+55°С Built-in temperature sensor Yes (sends data every time you connect) Built-in power supply charge measuring Yes (sends data every time you connect)
  • Page 9: Working With The Switching Device

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL 3. 3. WORKING WITH THE SWITCHING DEVICE CONTACTS DESCRIPTION 1. The device is powered by a 3.6 V power supply. Power supply is connected to "power" connector 2. Supplied cable is used to connect to the smoke detector terminals 3.
  • Page 10: Communications Protocol

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL 4. 4. COMMUNICATIONS PROTOCOL DATA PACKAGE FORMAT Data package format for the ROSSMA IIOT-AMS MODBUS switching device: The total amount of transmitted data in one package = 5 byte Package format for the SMOKE DETECTOR: example: cc000b5816 сс...
  • Page 11: Storage And Transportation Rules

    OPERATION MANUAL 5. STORAGE AND TRANSPORTATION RULES ROSSMA IIOT-AMS switching devices shall be stored in the factory package in heated rooms at temperature from 5 ° С to 40 ° С and with relative humidity not more than 85%. The switching devices can be transported in covered cargo compartments of all types for any distances at temperature from -40 °...
  • Page 12: Delivery Set

    ROSSMA IIOT-AMS Smoke Detector / OPERATION MANUAL 6. 6. DELIVERY SET The The standard delivery set ROSSMA IIOT-AMS includes: • ROSSMA IIOT-AMS Smoke Detector installed inside the ИП212-50М sensor - 1 pc. • Certificate - 1 pc. 1th revision 28.08.2019.
  • Page 13: Warranty

    - Switching devices with traces of oxidation or other signs of liquids ingress into the device housing. If a warranty case occurs, contact the service center of the ROSSMA manufacturer at: 614064, Perm, Chkalova Str., 9 Lit. "И". Phone: 7 (342) 233-93-99.
  • Page 14 Operation manual LLC ROSSMA 2019. www.rossma.ru...

Table of Contents