OmarLift C40 Instruction Manual

Homelift control unit
Hide thumbs Also See for C40:

Advertisement

INSTRUCTION MANUAL FOR HOMELIFT CONTROL
UNIT C40 - C50
Possibili cambiamenti senza preavviso!
D846MGB -Rev. 04
1/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OmarLift C40

  • Page 1 INSTRUCTION MANUAL FOR HOMELIFT CONTROL UNIT C40 - C50 Possibili cambiamenti senza preavviso! D846MGB -Rev. 04 1/14...
  • Page 2: Table Of Contents

    Contents Contents ..............................2 General information before installation ..................... 3 Description of the terminology ......................3 Description and operating principle ....................3 Responsibility and warranty ....................... 3 Health and Safety Warnings ......................3 Cleaning and pollution precautions ....................4 Installation manual ............................ 4 Installation manual –...
  • Page 3: General Information Before Installation

    Installation and repair technicians are the first maintaining hydraulic lifts. people to be responsible for their own safety. OMARLIFT is not liable for harm caused by improper use or use other than that prescribed in This Instruction Manual applies to the entire life of...
  • Page 4: Cleaning And Pollution Precautions

    OMARLIFT. Any situation that is not allowed by OMARLIFT (for reasons of patents, legal, technical or other reasons) is Cleaning and pollution precautions...
  • Page 5: Dimensions, Homelift System Range

    Dimensions, Homelift System Range 2.2.1 Homelift control unit Main components: 1 – Outer motor 2 - Pump 3 – Delivery pipe 4 – Pressure gauge 5 – Hand pump 6 – Filter block 7 – Electrical box Figure 2 8 - Tank 9 - Oil filling plug 10 –...
  • Page 6: System Range

    2.2.2 System range Static pressure Static pressure [bar] [bar] Effective total load on the rod Effective total load on the rod [kg] [kg] Figure 3 Static pressure [bar] Figure 4 Possibili cambiamenti senza preavviso! D846MGB -Rev. 04 6/14...
  • Page 7 Usable oil (liters) Table 3 NOISE LEVEL : Max 62 dB(A) at 1 meter distance in standard test conditions (*). (*) As confirmed by the measurement made in the room "TEST OMARLIFT" Possibili cambiamenti senza preavviso! D846MGB -Rev. 04 7/14...
  • Page 8: 1-Speed Homelift - Hydraulic And Speed Diagram

    2.2.3 1-speed HOMELIFT - Hydraulic and speed diagram Figure 5 2.2.4 2-speed Homelift - Hydraulic and speed diagram LEGEND: MAXIMUM PRESSURE VALVE CALIBRATION LOW SPEED ADJUSTMENT ADJUSTMENT OF COUNTERPRESSURE AND ROPE ANTI- FLEETING PRESSURE VALVE REACTION TEST CHOKE DEVICE FOR DECELERATING FROM HIGH TO LOW SPEED...
  • Page 9: Diagram Of 1-Speed Descent-Ascent Homelift

    2.2.5 Diagram of 1-speed descent-ascent Homelift Use and maintenance Piping and hydraulic connections For the connection of the control unit to the cylinder, both pipes made of standardized pickled cold-drawn steel and high-pressure hoses or mixed piping can be used. (Minimum curvature radius 240mm, ¾”...
  • Page 10: Calibration And Adjustment Of Homelift Valve

    The standard control unit box includes (see Figure ): Homelift valve, 2-speed  Electric motor U (1 - brown)  Electric motor V (2 - blue)  Grounding bolt  Motor guard (3 - black)  Motor guard (4 - gray) ...
  • Page 11: Maintenance, Inspection, Repair And Safety Emergency

    This table describes the function of each element. Maintenance, inspection, repair and safety TABLE OF VALVE SETTINGS FOR 1 and 2-speed emergency HOMELIFT valve SCREW DESCRIPTION SETTINGS General points Tighten to increase maximum calibration The hydraulic components are not subject to heavy Maximum valve pressure.
  • Page 12: Emergency Manoeuvre With Hand Pump

    Emergency manoeuvre with hand pump Replacing VBP valve seal The following procedure enables the air inside the hand pump to be eliminated. To check valves seal, proceed as follows: • If there are difficulties in priming the hand pump, To access the VBP valve piston, remove the shut off the main stopcock, use an Allen key (hex hand pump, if present (Figure 9) •...
  • Page 13 Possibili cambiamenti senza preavviso! D846MGB -Rev. 04 13/14...
  • Page 14 OMARLIFT SRL Via F.lli Kennedy, 22/D I – 24060 Bagnatica (BG) – ITALY Phone +39 035 689611 Fax +39 035 689671 E-mail: info@omarlift.eu Web: http://en.omarlift.eu Possibili cambiamenti senza preavviso! D846MGB -Rev. 04 14/14...

This manual is also suitable for:

C50

Table of Contents

Save PDF