600A AC/DC Clamp Meter, True RMS, NCV, Flashlight,
6000 Count
Pinza Amperimétrica CA / CC de 600 A, True RMS, NCV,
Linterna, 6000 Cuentas
Pince Ampèremétrique CA/CC 600 A, à Valeur Efficace Vraie,
Détection de Tensions sans Contact (NCV), Lampe-Torche,
Écran 6 000 Comptes
B07VX41MPR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B07VX41MPR and is the answer not in the manual?

Questions and answers

Summary of Contents for AMAZON COMMERCIAL B07VX41MPR

  • Page 1 600A AC/DC Clamp Meter, True RMS, NCV, Flashlight, 6000 Count Pinza Amperimétrica CA / CC de 600 A, True RMS, NCV, Linterna, 6000 Cuentas Pince Ampèremétrique CA/CC 600 A, à Valeur Efficace Vraie, Détection de Tensions sans Contact (NCV), Lampe-Torche, Écran 6 000 Comptes B07VX41MPR...
  • Page 2 English                        3 Español                      36 Français                      69...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included. When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following: WARNING...
  • Page 4 CAUTION Risk of damage! The clamps are breakable. Avoid dropping the product else, measurements in ampere become unreliable. • This product must be used by trained users only. • Do not exceed the maximum allowable input range of any measurement mode. Mode Maximum Input A~, A...
  • Page 5 • When changing ranges always disconnect the connector leads from the circuit under test. • Inspect the condition of the test leads and the product itself for any damage before operation. Repair or replace any damage before use. • Always discharge capacitors and remove power from the device under test before performing diode, resistance or continuity tests.
  • Page 6: Battery Warnings

    • Do not look directly into the light source. • Always remove the connector leads before replacing the battery. Battery Warnings • Always insert batteries correctly with regards to polarity (+ and –) marked on the battery and the product. •...
  • Page 7: Explanation Of Symbols

    Explanation of Symbols The signal word that indicates a hazard with a medium level of WARNING risk which, if not avoided, could result in death or serious injury. Indicates a practical tip, advice NOTICE or practice not related to personal injury. This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further...
  • Page 8 Direct current (DC). Earth (ground) terminal/potential. 600A Current measurement up to 600 A. Product is designed to protect the user during measurements performed on CAT II circuits directly connected to the low 1000V voltage installation. (up to 1000 V). Product is designed to protect the user CAT III during measurements performed in the building installation...
  • Page 9: Intended Use

    Intended Use • This product is intended to perform electrical measurements on CAT III locations (3-phase and single phase distribution) and CAT II locations (single-phase household appliances and tools). • This product is for indoor use only. • This product may be used only under the conditions and for the purposes for which it was designed.
  • Page 10: Product Description

    Product Description...
  • Page 11 Non-contact Function switch voltage probe tip PEAK/INRUSH Current clamp button Non-Contact V, Ω, CAP, Voltage Detector Hz, %, TEMP indicator input terminal Clamp trigger Flashlight Battery compartment button REL / cover Thermocouple Display probe adapter with caps Thermocouple RANGE button probe MODE / VFD Probe tip shrouds...
  • Page 12 9 10 VFD Variable frequency drive Relative mode Alternating Diode test current/voltage Direct Continuity current/voltage APO Auto power Minus sign °C/°F Temperature Low battery unit AUTO Automatic Unit of range setting measurement INRUSH current Hertz (Frequency) mode P MAX/MIN Duty cycle voltage peaks H Display hold Display reading...
  • Page 13 Function switch Position Function / Measurement AC/DC current up to 600 A AC/DC current up to 60 A Temperature Resistance / capacitance Continuity / diode test DC voltage AC voltage, Frequency, duty cycle, variable frequency drive mode...
  • Page 14: Changing Batteries

    Changing Batteries WARNING Risk of electric shock! Disconnect the product from any circuit, remove the test leads (S) from the input terminals (I)/(M), and turn OFF the product before opening the case. Do not operate the product with an open case. NOTICE Replace the batteries when the battery indicator (5) is show on the display.
  • Page 15 Automatic power OFF • In order to conserve battery life, the product automatically turns off after approximately 15 minutes. To turn the meter on again, turn the function switch (K) to the OFF position and then to the desired measurement mode. •...
  • Page 16 Display hold • To freeze the display reading, press the H / button (J). The H indicator (9) appears. • Press the H / button (J) again to return to normal operation. Changing the measurement range By default, the measurement range is set automatically and the AUTO indicator (6) appears.
  • Page 17 Zero the display • Press the REL / button (E) to zero the measured value (18). The indicator (1) appears. • Press the REL / button (E) again to show the absolute measurement. The indicator (1) disappears. Clamp measurement NOTICE Disconnect the test leads (S) from the product before making clamp measurements.
  • Page 18 • Set the function switch (K) to the 60A or 600A position. If the approx. range of the measurement is not known, select the highest range. Then move to the lower ranges if necessary. • Press the MODE/VFD button (H) to change the measurement mode.
  • Page 19 Inrush current flow • In AC current measurement mode, press the PEAK/INRUSH button (L) to measure the inrush current value. The INRUSH indicator (7) appears. • When the circuit is switched off, clamp on the circuit being tested for inrush. •...
  • Page 20 • Connect the test probes (S) in parallel to the circuit under test. • The stabilized value on the display (F) is read as the actual reading. Measuring AC voltage peaks • In AC voltage measurement mode, press the PEAK/INRUSH button (L) to measure the maximum peak and minimum peak values.
  • Page 21 • In AC voltage measurement mode, press and hold the MODE/VFD button (H) for 2 seconds. The VFD indicator (10) appears. • Connect in parallel the test probes (S) to the circuit or component being measured. • The stabilized value on (F) is read as the actual reading.
  • Page 22 Resistance measurement • Insert the black connector lead (S) into the negative COM (black) terminal (I) and the red connector lead (S) into the positive V (red) terminal (M). • Set the function switch (K) to the Ω/CAP position. • Connect the test probes (S) across the circuit or component being measured.
  • Page 23 • If OL appears on the display (F), remove and discharge the capacitor. • The stabilized value on the display (F) is read as the actual reading. NOTICE For very large values of capacitance measurement, it can take several minutes before the final reading stabilizes.
  • Page 24 Duty cycle measurement • Insert the black connector lead (S) into the negative COM (black) terminal (I) and the red connector lead (S) into the positive V (red) terminal (M). • Set the function switch (K) to the / Hz / % position.
  • Page 25 • Connect the test probes (S) across the circuit or component being measured. • If the measured circuit or component is electrically open, the display (F) shows OL. • If the resistance is <50 Ω, a beeping alerts that low resistance is measured. The stabilized value on (F) is read as the actual reading.
  • Page 26 NOTICE Forward voltage typically indicates 0.4 to 0.7 V. A shorted diode indicates near 0 V and an open diode indicates OL in both polarities. Temperature measurement • Insert the thermocouple probe adapter (P) with the black connector into the negative COM (black) terminal (I) and with the red connector into the positive V (red) terminal (M).
  • Page 27 NOTICE For longer period of measurements, use a thermal tape to attach the thermocouple probe to the surface being measured. NOTICE Risk of product damage! Disconnect the thermocouple probe (Q) before changing to other electrical measurement mode. Non-contact voltage measurement WARNING Risk of electric shock! Before use, always test the voltage detector on a known...
  • Page 28: Cleaning And Maintenance

    NOTICE The conductors in electrical cords are often twisted. For best results, rub the tip along the length of the cord to ensure getting the tip in close proximity to the live conductor. The product has high sensitivity. It is normal in its operation that static electricity or other sources of energy may randomly trip the sensor.
  • Page 29: Specifications

    • Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product. Storage • Store the product in its original packaging in a dry area. Keep away from children and pets. Specifications NOTICE *f.m. = from measurement AC true rms current Range Resolution...
  • Page 30 DC current Range Resolution Accuracy 60 A 10 mA ±2.0 % f.m.* ±8 digits 600 A 100 mA ±2.5 % f.m.* ±8 digits Overrange protection: Maximum input 600 A. AC true rms voltage (with VFD) Range Resolution Accuracy 6 V 1 mV 60 V 10 mV ±1.2 % f.m.* ±5 digits 600 V 100 mV 1000 V 1 V...
  • Page 31 DC voltage Range Resolution Accuracy 6 V 1 mV ±0.9 % f.m.* ±3 digits 60 V 10 mV ±1.0 % f.m.* ±3 digits 600 V 100 mV 1000 V ±1.2 % f.m.* ±3 digits Maximum input: 1000 V Resistance Range Resolution Accuracy 600 Ω 0.1 Ω ±1 % f.m.* ±4 digits 6 kΩ 1 Ω 60 kΩ...
  • Page 32 Capacitance Range Resolution Accuracy 99.99 nF** 0.01 nF ±4.5 % f.m.* ±20 digits 999.9 nF 0.1 nF 9.999 μF 0.001 μF 99.99 μF 0.01 μF ±3.0 % f.m.* ±5 digits 999.9 μF 0.1 μF 9.999 mF 0.001 mF 99.99 mF 0.01 mF ±5 % f.m.* ±5 digits Input Protection: 300 V or 300 V~ rms NOTICE ** < 99.99 nF (no specification) Frequency (AC current) Range Resolution...
  • Page 33 Continuity Measurement Output Test current Beeping tone when max. 1.5 mA resistance is less than (50 Ω) Input Protection: 300 V or 300 V~ rms. Diode Measurement Output Forward DCA is approx. Forward voltage drop of 1 mA, open circuit diode voltage max. 3 V Input Protection: 300 V or 300 V~ rms.
  • Page 34 General Power supply: 3 x 1.5 V Battery life: approx. 30 h (Flashlight on), approx. 100 h (Flashlight off) Max. measurement CAT II: 1000 V voltage: Cat III: 600 V Pollution degree: Clamp jaw opening: approx. 1.3" (33 mm) Display: 6000 counts backlit Measurement rate: 3 readings per second, nominal...
  • Page 35 Operating humidity: max. 80 % up to 87 °F (31 °C) decreasing linearly to 50 % at 104 °F (+40 °C). Storage humidity: <80 % Operating altitude: max. 7000' (2000 m) Auto power off: after approx. 15 minutes Feedback and Help Love it? Hate it? Let us know with a customer review.
  • Page 36 amazon.com/AmazonCommercial MADE IN CHINA HECHO EN CHINA FABRIQUÉ EN CHINE V01-10/19...