Download Print this page

Kenmore 1 For All TSTAT0713K Installation Manual page 15

Programmable temperature & humidity, heat cool & heat pump 2 heat - 2 cool, multi-stage
Hide thumbs Also See for 1 For All TSTAT0713K:

Advertisement

Every TSTAT0713K
is calibrated before it leaves the factory.
Under normal circumstances
there will never be a need to recalibrate
the TSTAT0713K
again.
To accommodate
special needs, the thermostat
may be recalibrated
following
these steps:
1. While pressing the MODE button, press the FAN button for
5 seconds. After all the icons in the display appear, release
the buttons.
2. Press the UP & DOWN buttons at the same time; the display will
change.
3. Press the UP & DOWN buttons at the same time again; the current room
temperature
will be displayed.
4. Use an accurate thermometer
to measure room temperature.
Press the
UP or DOWN buttons until the displayed temperature
equals the room
temperature.
5. Press the MODE button; the current humidity will be displayed.
6. Use an accurate hygrometer
to measure room humidity.
Press the UP or
DOWN buttons until the displayed
humidity equals the room humidity.
7. Press the mode button to return to normal operation.