Precautions
• This M-SURE micrometer is a precision measuring instrument, please avoid using excessive force and treat with care.
• The battery fitted is intended for the factory test procedure and therefore may not meet the specified battery life.
• Avoid exposure to all liquids, excessive humidity or temperature.
• Avoid exposure to bright sunlight.
• DO NOT rotate the spindle with the spindle lock engaged.
• Ensure the measuring surfaces are clean.
• Never apply voltage on any part of this digital micrometer or electric engrave the micrometer.
• Remove the battery if the micrometer is not being used for a long period of time.
• The spindle can not be removed, DO NOT travel past the upper or lower limit.
• Never use solvents to clean the micrometer Only use a soft cloth with cleaning oil.
Digital Micrometer
Twist to lock and unlock spindle.
Do not use excessive force.
8
Battery Replacement
1
1. Insert the key into the battery cover.
2. Twist to unlock. DO NOT use
excessive force.
7
6
6. Insert the replacement battery with
its edge against the side battery contact.
7. Press down on the opposite edge.
www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.
2
3
1
2
3. Lift out the battery cover.
8. Locate the three lugs on the battery
cover with the three slots on the
micrometer. Insert the battery cover.
4
5
7
3
5
4. Remove the battery.
be used)
5. Locate the side spring battery contact.
8
9. Twist to lock. DO NOT use excessive
force.
Part No: MS-110 Series
Doc V: 1.0
6
1. Frame
2. Anvil
3. Spindle
4. Spindle Lock
5. Display Head
6. Ratchet Thimble
7. Function Buttons