SAINT WIEN PROGRAMMABLE COUNTER/TIMER
CT-
CT- SERIES IS A PROGRAMMABLE COUNTER OR TIMER INDICATION/CONTROL METER.
AS A COUNTER ITS FUNCTION CAN BE SELECTED FROM 3 COUNTING VERSIONS AND 4 COUNTING SPEED.
THERE IS ALSO A WIDE PRE-SCALE SCALING RANGE FOR COUNTER.
FOR TIMING, THERE ARE 4 TIME RANGES.
ALL UNIT PROVIDES AUTO/MANUAL/POWER OFF RESET, EEPROM MEMORY, OFFSET, GATE FUNCTIONS.
#1 ELECTRICAL & GENERAL CHARACTERISTIC
1 SUPPLY VOLTAGE: 24,110,220VAC 50/60HZ
2 OPERATING VOLTAGE: 90~110% SUPPLY VOLTAGE
3 POWER CONSUMPTION: APPROX. 3VA~7VA
4 AMBIENT CONDITIONS: -10~55oC, 35~85%RH
5 WEIGHT: APPROX. 300~600g
6 SETTING METHOD: 4 KEYS TO SET/PROGRAMME uR[uR], MODE[M], SHIFT[<] & UP[^]
7 SETTING ACCURACY: 0%
8 INDICATION METHOD: 4 OR 6 DIGITS, 1 SET OF DIGITAL DISPLAY, CHARACTER HEIGHT
CT1-=14.2mm(4D,6D); CT2-=14.2mm(4D), 10mm(6D); CT3-=7.6mm(4D)
9 SIGNAL INPUT: HIGH ACTIVE 6~30VDC 3K3 OHM
10 CONTROL OUTPUT: (A) RELAY:3A250VAC RES. LOAD RESET)
11 POWER FOR SENSOR: (A) CT1-, CT2-:12VDC 60mA (B) CT3-:12VDC 20mA
12 PROTECTION: (A) EEPROM MEMORY BACKUP. (B) WATCHDOG.
(C) CPU RESET IF CORUPTED :HOLD [M] [<] [^] 3 KEYS PRESSED
uR [uR]:(A) TO RESET COUNTER, TIMER
(B) TO SELECT DP WHEN USED WITH [<] (EXCEPT TIMER)
TO SAVE SETTING VALUE
(C)
MODE [M]:TO CHECK/SET PARAMETTERS
SHIFT [<]:(A) TO SHIFT DIGIT
(B) TO CHECK/SET OFST, DSP WHEN USED WITH [M]
UP [^]:(A) TO INCREASE NUMERAL
(B) TO CHECK/SELECT COUNT SPEED, TIMER RANGE, NCR
WHEN USED WITH MODE [M]
(C) TO CHECK/SELECT MODEL WHEN USED WITH [<]
AND POWER ON AGAIN. AFTER THE METER IS RESTORED TO NORMAL
OPERATION, RE-CONFIGURE THE METER FOR THE REQUIRED FUNCTIONS
1/4

Advertisement

loading

Summary of Contents for Intech CT Series

  • Page 1 SAINT WIEN PROGRAMMABLE COUNTER/TIMER CT- SERIES IS A PROGRAMMABLE COUNTER OR TIMER INDICATION/CONTROL METER. AS A COUNTER ITS FUNCTION CAN BE SELECTED FROM 3 COUNTING VERSIONS AND 4 COUNTING SPEED. THERE IS ALSO A WIDE PRE-SCALE SCALING RANGE FOR COUNTER. FOR TIMING, THERE ARE 4 TIME RANGES.
  • Page 2 #2 SPECIFICATIONS * COUNTER 1 3 COUNTING VERSIONS(FIG 1C,1D); 4 COUNTING SPEEDS(FIG 5A,5B). 1) ONE WAY(UP COUNTING):30,100,300,FLOATING(3000HZ) 2) PHASE IN CYCLE COUNT:15,50,150,FLOATING(2000HZ, CYCLE COUNTx1=2,000 COUNT) 3) PHASE IN EDGE COUNT :15,50,150,FLOATING(1000HZ, EDGE COUNTx4=4,000 COUNT) 2 PRE SCALE FACTOR(DSP): 000.000~999.999(EXCEPT WHEN FLOATING COUNTING SPEED INPUT IS SELECTED) 3 OPERATION MODES 1 OR 2 PRESET OR INDICATION ONLY 4 RESET: (A)AUTO/MANUAL MODES: N.C.R, 000.000~999.999S ADJUSTABLE FOR AUTO...
  • Page 3 #4 PRESET/RESET SETTING (FOR P1,P2 & AUTO RESET MODE C,R) PRESET =(SETPOINT) RESET TIME =(RELAY HOLD IN TIMER AFTER TIMER OR COUNTER SETPOINT HAS ELASPED) AUTO RESET MODE C=RELAY TIME DELAY FOR MODE C AUTO RESET MODE R=RELAY TIME DELAY FOR MODE R 1 PRESS [M].
  • Page 4 C=AUTO RESET/WITH RELAY TIMER (COUNT RESETS AND RELAY CLOSES AT SETPOINT UNTIL RELAY TIMER ELAPSES) R= AUTO RESET/WITH RELAY TIMER (COUNT CONTINUES PAST, AND RELAY CLOSES AT SETPOINT UNTIL RELAY TIMER ELAPSES) COUNTER RESETS AFTER RELAY TIMER ELAPSES 5 PRESS [M] TO RETURN TO MAIN SCREEN DISPLAY #7 TIMER RANGE &...

This manual is also suitable for: