Download Print this page

Intech CT Series Manual page 3

Saint wien programmable counter/timer

Advertisement

#4 PRESET/RESET SETTING (FOR P1,P2 & AUTO RESET MODE C,R)
PRESET =(SETPOINT)
RESET TIME =(RELAY HOLD IN TIMER AFTER TIMER OR COUNTER SETPOINT HAS ELASPED)
AUTO RESET MODE C=RELAY TIME DELAY FOR MODE C
AUTO RESET MODE R=RELAY TIME DELAY FOR MODE R
1 PRESS [M]. TO CHANGE DISPLAY FROM MAIN SCREEN TO "P1"
2 USE SHIFT [<] TO SELECT DIGIT,
THE SELECTED DIGIT WILL FLASH.
3 USE UP [^] TO SET REQUIRED NUMERAL.
4 PERFORM STEP 2,3 FOR ALL DIGITS OF P1
5 PRESS [M] AFTER SETTING TO DISPLAY P2
6 PERFORM STEP 2,3 FOR ALL DIGITS OF P2
7 PRESS [M] AFTER SETTING TO DISPLAY
SETTING OF C OR R
8 REPEAT STEP 2,3 FOR ALL DIGITS OF C(R)
* NO RESET TIME IF SELECT N MODE
9 PRESS [M] TO RETURN TO MAIN SCREEN
#5 OFSET/PRESCALE (DSP) SETTINGS
OFST = (OFFSET BEFORE COUNT/TIME IS STARTED)
DSP = (DISPLAY VALUE EQUALING 1 COUNT INPUT)
DSP=1/NO.OF INPUT PULSES
1 HOLD [<] THEN [M]. TO CHANGE DISPLAY
FROM MAIN SCREEN TO OFST
2 USE SHIFT [<] TO SELECT DIGIT,
SELECTED DIGIT WILL FLASH.
3 USE UP [^] TO SET REQUIRED NUMERAL.
4 REPEAT STEP 2,3 FOR ALL DIGITS OF OFST.
5 PRESS [M] AFTER SETTING TO DISPLAY DSP.
6 PERFORM STEP 2,3 FOR ALL DIGITS OF DSP
7 PRESS [M] TO PV DISPLAY
THE COUNTER DISPLAYS ONLY INTEGRAL (WHOLE NUMBERS) (AND RETAINS THE FRACTION PARTS
IN METER) USE DSP TO MEASURE THE TRUE MAXIMUM ACCURATE OF ENGINEER'S UNIT OF COUNT,
SUCH AS LENGTH, VOLUME, QUANTITY & ETC.
AFTER MAKING CHANGES PUSH uR TO SAVE SETTINGS
#6 COUNT SPEED & NCR
COUNT SPEED (C)= INPUT PULSE FREQUENCY
NCR
(NCR)= RESET MODE
1 HOLD UP [^] THEN PRESS [M]. TO CHANGE DISPLAY FROM MAIN SCREEN TO COUNT SPEED
2 USE UP [^] TO SELECT COUNT
SPEED. 4 COUNT SPEEDS AVAILABLE (USE THE CORRECT SPEED FOR THE EXPECTED INPUT
FREQUENCY)
3 PRESS [M] TO DISPLAY NCR SETTING.
4 USE UP [^] TO SELECT 1 OF N.C.R.
N=MANUAL RESET (COUNT CONTINUES UNTIL RESET,
RELAY CLOSES AT SETPOINT UNTIL RESET)
3/4