Page 1
Divider “nano Progressive” User operation and Maintenance manual Original instruction INDEX INTRODUCTION GENERAL DESCRIPTION TECHNICAL CHARACTERISTICS DIVIDER BLOCKS AND LABELLING CYCLE MONITORING DEVICES PRESSURE INDICATOR TUBES, FITTINGS AND VALVES DIVIDERS ASSEMBLY ORDERING INFORMATION DIMENSIONS TROUBLESHOOTING MAINTENANCE PROCEDURE DISPOSAL HANDLING AND TRANSPORTATION...
This divider allows lubrication systems to distribute oil and grease with working pressure up to 300bar (4350psi). You can obtain the latest release of this document by contacting a Dropsa sales office or distributor or by visiting us on the World Wide Web at http://www.dropsa.com.
Page 3
4.2 METERING ELEMENT Metering elements are available with 4 different flow rates. Each nP- Nano Progressive can be assembled with a minimum of 3 elements and maximum of 12. PART DESCRIPTION Q. cm³ NUMBER 0,025 0645750 nP 025-DIVIDERS "nano Progressive"...
Page 4
B) Visual monitoring pin with colour strip. This must be ordered with the divider element. DIVIDER with colour strip visual indicator Q. cm³ PAR NUMBER DESCRIPTION 0,025 0645778 VISUAL INDICATOR nP 025 "nano Progressive" 0,045 0645779 VISUAL INDICATOR nP 045 "nano Progressive" 0,075 0645780 VISUAL INDICATOR nP 075 "nano Progressive"...
Page 5
6. OVER-PRESSURE INDICATOR Pressure indicators are used to control pressure in main or secondary tubing. They can be applied directly on the alternate outlet/indicator port that is standard on all nP divider elements. There are three types of indicators that give a different visual indication linked to the pressure set on the device.
Page 6
8. DIVIDER BLOCKS ASSEMBLY To order a Pre-assembled Assembly the following ‘string’ formation is used to identify the sequencing of the elements and the order of assembly. −...) INLET Config. and PACK ELEMENT configuration (repeat for N° element) PRESSURE COTROL OUTLET N°...
Page 7
9. ORDERING INFORMATIONS INLET ELEMENT PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 0645747 0645748 INLET - nP "nano Progressive" S - 20mm reduced hole centers INLET - nP METERING ELEMENT Q.cm³ PART NUMBER DESCRIPTION Q.cm³ PART NUMBER DESCRIPTION 0,025 0645750 nP 025-DIVIDER...
Page 8
10. DIMENSIONS 0645747 - INLET nP – standard version 0645748 - INLET nP -S 20mm reduced hole centers mm [inch] mm [inch] N° N° “A” “B” “C” “D” “A” “B” “C” “D” elements elements 76.3 82.8 [3.26] 90.3 96.8 [3.55] [3.82] 104.3 110.8...
• Skin contact with oil -> see requirements for the use of appropriate PPE; • Unsuitable Lubricant. Lubricant characteristics are indicated on the pump and in this user manual. In any case contact a Dropsa Sales and Support engineer (if in any doubts, contact the Technical Department Dropsa SpA); by the •...