The GD-06 ALLEGRO is a universal GSM dialer and
controller. It can be used for both home and industrial
automation purposes, for security applications or any remote
data transfer project. Triggering of any of the inputs will
cause the sending of a reporting SMS message to
preprogrammed phone numbers or a direct call to a
telephone number. By using specific text messages, you can
switch on or off the remote controlled outputs. In the basic
setting, the GD-06 provides 4 inputs and 3 outputs.
The device can be programmed using programming SMS
messages or via the Internet using Jablotron's GSMLink web
page.
The Expert mode enables full programming of all inputs and
outputs,
trigeering
a
communication and analogue data transmission.
1. Specification
Power supply voltage
Current consumption
GSM band
Terminals (P1 - P6):
Output mode - transistor output (max. 100 mA), switches to
Relay output
Dimensions
Complies with
Hereby, Jablotron Ltd., declares that this GD-06 complies with the
essential requirements and other relevant provisions of Directive
1999/5/EC. Original conformity assessment can be found at the web
page www.jablotron.cz, section Technical support.
2. Installation
The GD-06 ALLEGRO is designed for indoor use only.
Check the GSM signal strength before installing the product
(e.g. with a GSM phone using a SIM card for the same
operator).
1)
Insert a SIM card into a GSM phone and disable its PIN.
If you cannot disable it, set it to 1234.
2)
Insert the SIM card into the GD-06.
3)
Connect the power supply.
4)
The LED will start flashing until the SIM card registers
into the GSM operator's network (max. 1 minute).
5)
Standby mode is then indicated by short flashes of the
LED (apr. once every 2 sec). If the LED is lit
permanently, GSM communication is in progress.
GD-06 ALLEGRO GSM dealer
GD-06 ALLEGRO GSM Dialer
listening-in
mode,
GPRS
8 - 15 V DC
20 mA (stand-by), 500 mA
(maximum)
E-GSM/GPRS
900/1800MHz
(2 W @ GSM900, 1 W @
GSM1800)
Input mode - triggered when
connected to GND (200 ms
filter is used)
GND
over-switching contact (NC-C-
NO), max. 2A / 24V
76 x 110 x 33 mm (antenna -
125 mm)
EN 60950, EN 301489-7, ETSI
EN 301489-7, EN55022, EN
50130-4, EN 301511
Terminals' description:
Terminal
Power
supply
GND
Inputs
data
Outputs
Wire outputs of your triggering devices (e.g. sensors, alarm
systems...) to corresponding input terminals of GD-06. Wire
the appliances which you want to control remotely to the
output terminals of the GD-06.
Note: After the installation, all telephone numbers are erased
from the memory and access codes are set to MASTER and
USER.
3. Basic setting
3.1. Reset
Reset the GD-06 communicator to the factory default
settings with English communication by sending the
instruction
"MASTER RESET EN" to the dialer
3.2. Telephone numbers setting
Store the telephone numbers TEL1 to TEL8 using the
programming SMS instruction sent from a GSM phone:
MASTER TELX YYY ZZZZZZZZZZZ
Parameter
X
YYY
ZZZZZZZZZ
Example: "MASTER TEL1 SMS 00420483559911"
You will then receive a confirmation message from the GD-
06 to your mobile phone.
Notes:
There must be spaces between the parameters. The SMS
instruction is case insensitive.
For telephone numbers TEL7 and TEL8, which are used
for remote control only, you can use any YYY parameter.
To delete the telephone number, send the SMS instruction
"MASTER TELX DEL", for example "MASTER TEL3
DEL".
If the confirmation message is not in English, reset the GD-
06 as described in the paragraph 3.3.
1/2
Mode
Terminals for connecting
+U
8-15 V DC power supply
voltage
Connecting or disconnecting
P1
to GDN will trigger sending
P2
SMS
P3
information to all telephone
P4
numbers TEL1 – TEL6.
Example: "P1 On" or "P2 Off"
SMS instruction sent from
TEL1-TEL8 telephones
P5
controls
P6
the outputs.
Example: "ON P5" or "OFF
P6"
Relay switches over
NC
(on/off/on...)
C
whenever a phone call from
NO
TEL1 or TEL2 is detected.
.
Value
1,2,3,4,5,6,7,8
Memory position for TEL1
to TEL8
SMS
Instruction to send SMS to
this number
SMS+
Instruction to send SMS to
this number first and then
to call this number
Telephone number (max
20 digits) , "+" prefix can
be used for international
calls
Telephone
numbers
-
TEL1, TEL2,
TEL3, TEL4,
TEL5, TEL6
TEL1, TEL2,
TEL3, TEL4,
TEL5, TEL6,
TEL7, TEL8
TEL1, TEL2
Description
MHG51302

Advertisement

loading

Summary of Contents for jablotron GD-06 ALLEGRO

  • Page 1 GD-06 ALLEGRO GSM Dialer Terminals’ description: The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial Telephone Terminal Mode automation purposes, for security applications or any remote numbers data transfer project. Triggering of any of the inputs will...
  • Page 2 4. Operation 3.3. Customization of SMS texts and access codes After installation of the GD-06 ALLEGRO and programming of the telephone numbers, the GD-06 is ready for operation. The default texts of reporting SMS and incoming SMS • Triggering of any input P1 to P4 will cause the sending...