    Contents INTRODUCTION……………………………….…………..……...…3 INTENDED USE…………………………….…………..………....3 IMPORTANT SAFETY INFORMATION……………………....…3 BODY TEMPERATURE……………………………….......5 PACKAGE COMPONENTS……………………………..….....…5 PRESENTATION……………………………..……….………....6 BEFORE USE……………………………......……....…7 HOW TO MEASURE FOREHEAD TEMPERATURE…………....8 HOW TO MEASURE OBJECT EMPERATURE………………..……9 HOW TO MEASURE AMBIENT TEMPERATURE…………....…10 TEMPERATURE TAKING HINTS……………………………....11 TEMPERATURE INDICATION……………………………....…11 CHECK THE MEMORY……………………………..……....…12 CELSIUS/FAHRENHEIT OPTION……………………………....12 REPLACING THE BATTERY……………………………....……13 SPECIFICATIONS……………………………..……….…....…14 CARE AND CLEANING……………………………..…….....….15 CALIBRATION……………………………..……………….....…15...
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing Digital Non-contact Forehead Thermometer TH5001N from Shenzhen Dongdixin Technology Co., LTD. The thermometer has been carefully developed for accurate, safe ,fast and contact-free human body temperature measurements (at a distance of approximately 2-5cm) in the forehead and object temperature measurements.The reference body site is core and the mode of operation is adjusted mode.
  • Page 4 The above phenomenon does not affect the basic safety and essential performance of the device, and the user can use it according to the instruction. If you want to avoid the above phenomenon, please use it according to the environment specified in the manual. ...
  • Page 5: Body Temperature

     If your thermometer will not be used on a regular basis, remove batterery to prevent possible damage due to chemical leakage. If battery does leak, remove carefully. Do not allow bare skin to touch leaking fluid.  This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
  • Page 6: Presentation

    PRESENTATION Operation panel 1)Measurement button 2)Battery cover 3)Spotlight head 4)Infrared sensor 5)Bi-colour light 6)LCD 7)C/F button 8)Mode button 9)Memory button - 6 -...
  • Page 7: Before Use

    LCD display 1)Spotlight symbol 2)Temperature/data display 3)Forehead temperature symbol 4)Object temperature symbol 5)Ambient temperature symbol 6)Fahrenheit symbol 7)Celsius symbol 8)Low battery symbol 9)Memory symbol BEFORE USE 1. To achieve accurate measurement, it is very important to check the infrared sensor and sure it is clean before using. To clean the sensor, gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab.
  • Page 8: How To Measure Forehead Temperature

    HOW TO MEASURE FOREHEAD TEMPERATURE 1. Place the thermometer in your hand as shown with your thumb on the [Measurement] button.  Do not press the button yet.  Make sure the probe is clean before measuring. 2. Place the infrared sensor of the thermometer in the middle of the forehead, and press the [Measurement] button to start the measure.
  • Page 9: How To Measure Object Emperature

    HOW TO MEASURE OBJECT EMPERATURE 1. Hold the thermometer and ensure the Infrared sensor is around 2-5 cm from the liquid or surface whose temperature you want to measure. Press the [MODE] button in the forehead temperature mode, and the thermometer will enter the object measurement mode.
  • Page 10: How To Measure Ambient Temperature

    HOW TO MEASURE AMBIENT TEMPERATURE 1. Hold the thermometer, press the [MODE] button in the object temperature mode, and the thermometer will enter the ambient measurement mode.  Make sure don’t use this mode to measure body temperature. 2. Keep the infrared sensor still, measure the ambient temperature and display the temperature within 1 ~ 2 seconds.
  • Page 11: Temperature Taking Hints

    TEMPERATURE TAKING HINTS 1. External factors may influence forehead temperature. particularly when an individual has:  been exposed to very hot or very cold temperatures.  been recently swimming or bathing.  had their forehead covered. In these cases, let the individual stay away from the above scenario and station in a room for 30 minutes prior to talking a temperature.
  • Page 12: Check The Memory

    CHECK THE MEMORY In the state other than the sleep state, press the [MEN] button to enter the memory state.  If no data has been stored, the screen displays "-"; if there is already stored data, press and hold the [MEN] button, then the screen displays the number, release [MEN] button to display the measurement result and measurement mode, and up to 30 groups of data can...
  • Page 13: Replacing The Battery

    REPLACING THE BATTERY When the low battery indicator “ ” appears on the LCD, or the thermometer does not function at all, you should replace new battery as soon as possible. The thermometer is supplied with one battery (Type 6F22). Move the battery cover, and pull up the batteries, then insert new battery into the battery compartment.
  • Page 14: Specifications

    SPECIFICATIONS Power supply: DC 9V(1×6F22) Body measuring range: 32.0°C ~ 42.9°C (89.6°F ~ 109.3°F) ±0.2°C(±0.4°F) for ~42.0°C (107.6°F) 35.0°C (95.0°F) Laboratory accuracy: ±0.3°C (±0.5°F) for other range Object measuring range: 0°C~100°C(32.0°F~212.0°F) Object measuring accuracy: ±2.0°C(±4.0°F) Displayed room 5.0°C ~ 59.9°C (41.0°F~139.8°F) temperature range: Room temperature accuracy: ±1°C (±2°F)
  • Page 15: Care And Cleaning

    CARE AND CLEANING To ensure accurate measurements, keep the infrared sensor clean and free of scratches is very important. Finger prints, dirt will affect the accuracy of the thermometer. In order to get an accurate measurement, please clean the infrared sensor. Gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Troubles Checklists Counter measures Battery used up? Change new battery No response / Battery in wrong or take out battery Automatic reset when polarity? and reinsert correctly pull out insulator Poor battery contact The measured temperature is lower The temperature than 32.0°C/89.6°F Follow User's Manual measurement shows...
  • Page 17 Troubles Checklists Counter measures Please check if you Please keep the have let the thermometer and thermometer and patient in the patient gets stabilized measuring room at in the room for 30 least 30 minutes The measurement is minutes at least before using not accurate or if there is any doubt of the...
  • Page 18: Normalized Symbols

    NORMALIZED SYMBOLS Applied part of type BF Disposal in accordance with Directive 2012/19/EU (WEEE) Complies with the European Medical Device Directive (93/42/EEC) and amended by directive 2007/47/EC requirements. Notified body TÜV Rheinland (CE0197) The name and the address of the manufacturer The name and the address of the Authorized EC-representative in Europe Caution...
  • Page 19: Disposal

    DISPOSAL Exhausted battery does not belong to household waste. Dispose the battery according to the current federal, state and local regulation. As a consumer, you are obligated by law to return the used batteries. NOTES: 1) Under the environment with electrostatic discharge, the unit may malfunction and may require user to reset the unit.
  • Page 20: Important Information Regarding

    more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –...
  • Page 21 - 21 -...
  • Page 22 - 22 -...
  • Page 23 - 23 -...
  • Page 24 - 24 -...
  • Page 25 - 25 -...
  • Page 26 - 26 -...
  • Page 27 - 27 -...
  • Page 28 Shenzhen Dongdixin Technology Co., LTD. Floor 1-2, No.3 Building, Fanshen Xusheng Industrial Estate Xilixiaobaimang 518108 Nanshan District, Shenzhen P. R. China Tel: 0086-755-27652316 E-mail: service@e-caretalk.com www.e-caretalk.com Shanghai International Holding Corp. GmbH (Europe) Eiffestraße 80, 20537 Hamburg Germany Tel: 0049-40-2513175 Fax: 0049-40-255726 Copyright 2020 by Shenzhen Dongdixin Technology Co., Ltd.

Table of Contents