Termoventiler AB THERMOMATIC EC HOME Quickstart Manual For Installation And First Start-Up

Hide thumbs Also See for THERMOMATIC EC HOME:

Advertisement

Quick Links

THERMOMATIC EC HOME
Quickstart Guide for installation and fi rst start-up
NB! When using wireless room sensor, several steps are factory-set. See page 4.

1 Fitting the motor to a mixing valve

Fit the motor to the mixing valve according to the instructions on the respective
installation kit (example shown in photos 1 and 2). Which installation kit is to be used
depends on the mixing valve, see the table and instructions in the installation kit.
Fit the plate (blue/red) for the mixing valve's position indicator on the motor and fi x the
handle according to photo 3. NB! The motor is always delivered in the centre posi-
tion and the handle only fi ts in the position that the motor is in. Insert and tighten the
screw in the centre of the motor.
Turn the motor to manual position (photo 3). NB: The handle must only be turned. If
the handle is depressed it may stick in the manual position.
Check that the mixing valve's working area agrees with the position of the handle.

2 Installation of the CC

Install the CC with the motor frame bracket as shown in photo 4. NB! The bracket
can be located on either side of the motor and is pressed into place from behind. The
click lock is pressed into the slot until it says "Click" (photo 5). You can use e.g. a small
screwdriver to remove the click lock.
The click lock is loose inside the CC on delivery when the CP is not fi tted to the CC. If
not, it is in the cardboard box.
The CC can also be fi tted separately, e.g. on a wall. The box size is adapted for exte-
rior fi tting on a 70 mm electrical box (e.g. wall socket).

3 Installing the supply sensor

Attach the sensor with the enclosed installation kit on the supply pipe (photo 6) as
close to the mixing valve as possible. Ensure that there is good contact. Insulate.
ECHOME_Quickstart_EN.indd
821500-E
160831
+46 (0)321 - 261 80 • info@termoventiler.se • www.termoventiler.eu
Termoventiler AB
®
1
2
3
4
5
6
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THERMOMATIC EC HOME and is the answer not in the manual?

Questions and answers

Summary of Contents for Termoventiler AB THERMOMATIC EC HOME

  • Page 1 ® THERMOMATIC EC HOME Quickstart Guide for installation and fi rst start-up NB! When using wireless room sensor, several steps are factory-set. See page 4. 1 Fitting the motor to a mixing valve Fit the motor to the mixing valve according to the instructions on the respective installation kit (example shown in photos 1 and 2).
  • Page 2 4 Cabling Installing the 4 conductor cable: Lay the whole cable between the CC and the CP before connecting to the respective units. 5 Connection of the CC Insert the cable through the cable entry. We recommend that you knot the cable as a cable grip (photo 7). The terminal block can be removed (photo 8) and is pushed into place on the stud after the cables are connected.
  • Page 3 7 Installing the CP or separate room sensor The CP can be fi tted on the CC or on the wall using the enclosed installation kit (plug and screw). In its standard design, the CP has an integrated temperature sensor that is used as the room sensor. The position of the CP is therefore decisive for correct operation when using the room sensor function.
  • Page 4 ® THERMOMATIC EC HOME Quickstart-guide when using wireless room sensor Other installations and functions are explained in the complete manual for the wireless room sensor Locating the antenna: Antenna should not be Antenna should not be Antenna should not be...

This manual is also suitable for:

Thermomatic ec home wl

Table of Contents