Short Circuit and Overload Protection ............10 CS-DMX Series Typical Wiring Applications ..........11 Warranty All CS-DMX Series control stations come with a standard two (2) year limited warranty against defects in parts and workmanship. User Manual Copies Additional copies of the most recent version of this manual can be downloaded at: http://www.johnsonsystems.com/pdf_files/jsi_cs_dmx_manual_rev_1.pdf.
Tough, durable powder coat paint on 0.080” aluminum laser cut faceplate for a scratch resistant non-glare finish. • Color matched and sized for use with Johnson Systems AP Series adapter plates where necessary to adapt to existing (larger) electrical back boxes.
CS-DMX Series Control Station Diagrams "ON", "DIM", and "OFF" Buttons With Integral LED's Master (M) Slider Infared LED Sensor Secondary (3, 6, 9, or 12) Sliders 6-Position Connector (J1) For: • Power Supply Input (COM, V+) • Button Contacts (ON, DIM, RST) •...
“ON”, “DIM” and “OFF” Buttons with Integral LED’s All CS-DMX Series control stations contain 3 buttons with integral blue LED’s. When a button is pressed, the control station is triggered into the corresponding state. The button LED’s indicate the state of the control station. Under normal operation, when a button is pressed, the corresponding LED will illuminate.
3.5Lb-In (0.4Nm). DMX Input and Output Wiring All CS-DMX Series have a 3-position breakaway connector used to receive DMX in (DMX IN) and a 3-position breakaway connector used to transmit DMX out (DMX OUT). The DMX received on the DMX in (if applicable) connector is merged with the DMX generated by the control station and retransmitted through the DMX out connector.
Wiring an Independent Control Station An independent control station requires 2 conductors for V+ and common, and a single DMX cable for the DMX out connection. CS-DMX-12 DC POWER SUPPLY COMMON (V-) INPUT DC POWER SUPPLY POSITIVE (V+) INPUT DMX OUT Wiring a Single or Multiple Entrance Control Stations to a Master Control Station An entrance control station (Part Numbers: CS-SA-ENT2B and CS-SA-ENT3B) is typically...
Calibrate the DMX Output Range All CS-DMX Series control stations are factory calibrated for 0-100% DMX control with a 10.6VDC to 18VDC power supply. If the control station does not have a full range of DMX control, please consult a factory representative.
Time Fade The control station is capable of fading from: “OFF” “ON” “ON” “OFF” “OFF” “DIM” “DIM” “OFF” The control station is capable of pseudo fading from: “DIM” “ON” “ON” “DIM” The control station automatically begins fading when a button is pressed. The button LED flashes on and off once per second to indicate fading.
Local Lockout Mode Activation When the local lockout mode is activated, the control station is locked in the “OFF” state. Any button press is ignored and the “OFF” LED flashes once to indicate local lockout mode is activated. Procedure: • To activate the local lockout mode, press and hold the “OFF”...
CS-DMX Series Typical Wiring Applications www.johnsonsystems.com...
Page 12
CS-DMX Series Programmable Manual DMX Stations Model Description # Wires Back Box Minimum PCB Clearance CS-DMX-3-? 1 gang, 3 channel manual control 2 x #18 AWG 2 gang 3.60"W x 2.75"H x 2.00"D +DMX 9.1cm x 7.0cm x 5.1cm w/master slider, on, preset, and off...