Technologies Inc. to notify any person or organization of such revision or changes. RBH ACCESS TECHNOLOGIES INC. 2 Automatic Road, Suite 108 Brampton, Ontario CANADA L6S 6K8 www.rbh-access.com UNC100 Axiom Hardware Manual V1.2 RBH Access Technologies Inc. Page 2 of 25...
Reduced the number of pages. Minor editing of text. 03/24/14 Changing output voltage from 07/21/14 12V to 12v – 14v Changing battery charger spec Minor editing. 07/31/14 ULC text added. 08/06/14 UNC100 Axiom Hardware Manual V1.2 RBH Access Technologies Inc. Page 3 of 25...
IOC-16 controllers, and PC100. 3) Controller Communications for controllers such as additional UNC500s or for NC100s via UNC-NET which is protocol designed for RS485 communications between UNC500s and UNC100s only. UNC100 Axiom Hardware Manual V1.2 RBH Access Technologies Inc. Page 7 of 25...
Ethernet Secure Mode Controller Baud Rate Not used DIP switch 5 up will enables Ethernet Secure Mode. This will prevent access to the panel’s programming through the Ethernet. UNC100 Axiom Hardware Manual V1.2 RBH Access Technologies Inc. Page 8 of 25...
The master controller is connected to either a serial port on the PC or through the local Ethernet via a static IP address. The means of communication is configured in the AxiomV™ software under Network Properties/Port Type. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 10 of 25...
4000 feet (1200 meters) For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 11 of 25...
PC to UNC100 Connection - LAN For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 12 of 25...
Set the RS485 to HOST in order to connect via RS485 to the PC. This is a string of up to 10 characters that allows the user access Telnet Password password to this program. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 13 of 25...
Page 14
UNC-NET (Controller Network) When combining UNC500s and UNC100s; connect the RS485 of the previous UNC100 to CH3 (Configured as NC-NET) of the UNC500. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 14 of 25...
A tamper wire may be connected to JP1 located close to the center of the board. A short to this input is normal and an open is alarm. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 15 of 25...
Up to four RC-2 reader controllers (The UNC100 is configured for 1, then you can connect 3 physical RC2s), and up to sixteen IOC-16 input/output controllers, may be connected to each network controller in the UNC-NET using high speed RS485 communications. D-NET (Device Network) UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 16 of 25...
Page 17
IOC-16, PC-100 1-255 SafeSuite™ panel * The first RC2 is on the NC100 – Therefore, the first physical RC2 to be connected will start at address 2. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 17 of 25...
Page 18
D-NET (Device Network) Connection Example UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 18 of 25...
For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. Reader wire colours may vary for different reader manufactures. Please verify your wiring. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 19 of 25...
The Buzzer emits one long beep and the green LED turns on for the duration of the unlock time. Access Denied The Buzzer emits two short beeps and the red LED flashes twice. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 20 of 25...
All of these devices generate extremely high voltage spikes (several thousand volts) when applied power is removed. Possible disruption of operation could occur if this interference gets on to the electronic circuit board. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 21 of 25...
This input can be used as a general- purpose input if the door contact is not required. If not used, leave the default DC settings in the AxiomV™ software configuration. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 22 of 25...
Open Circuit Alarm Normally Open, No Resistor Loop Resistance State Short Alarm Open Circuit Restore Normally Closed, One Resistor Loop Resistance State Short Trouble Restore Open Circuit Alarm UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 23 of 25...
Page 24
This circuit type is used where normally open and normally closed contacts are used in the same loop. For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. UNC100 Axiom Hardware Manual V1.1 RBH Access Technologies Inc. Page 24 of 25...
Need help?
Do you have a question about the UNC100 Axiom and is the answer not in the manual?
Questions and answers