  • Page 1 -FLATSCAN SW ® SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS Visit website for available languages of this document. 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 1 of 16 Page 1 of 16...
  • Page 2: Led Signals

    Error Exit the zone and wait LED flashes LED flashes LED flashes LED flashes LED is off LED flashes x times red/green slowly quickly Page 2 of 16 Page 2 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 3 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 3 of 16 Page 3 of 16...
  • Page 4 Using a wire cutter, remove the positioning tabs Fasten the 3 screws using a screwdriver. from the mounting base. Page 4 of 16 Page 4 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 5 «click» Use a plug to close the secondary sensor. Secure the lock screw to avoid vibrations during door movement. 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 5 of 16 Page 5 of 16...
  • Page 6 Do not use a 24V transformer and rectifier as this will cause damage to the product. ** Output status when sensor is operational (can be NO or NC) Page 6 of 16 Page 6 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 7: Dip Switches

    Once the door is completely closed again and the LED is off, the teach-in is complete. 2. FIELD WIDTH 3. LEARN Primary < 1 sec. 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 7 of 16 Page 7 of 16...
  • Page 8: Testing And Adjusting

    Do not hesitate to push. cover loosens. Watch our FLATSCAN SW tutorial online: bea-flatscan.com/tutorial SERVICE MODE Service Mode deactivates all detection fields for 15 minutes and can be useful during an installation, a mechanical learn of the door, or maintenance work.
  • Page 9 * The actual dimensions depend on the mounting height (40 in at 13 ft) no field 157 in A teach-in overwrites these values automatically. 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 9 of 16 Page 9 of 16...
  • Page 10: Output Configuration

    7 factory reset of factory reset of all values all values except field dimensions and output configurations Page 10 of 16 Page 10 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 11: How To Use The Remote Control

    CHECKING A VALUE x = number of flashes = value of the parameter = field width: 2.35 m RESTORING TO FACTORY VALUES partial reset full reset 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 11 of 16 Page 11 of 16...
  • Page 12: Troubleshooting

    It is not possible to adjust Wrong DIP switch position. Adjust the required DIP switches a setting by remote to ON. control. Page 12 of 16 Page 12 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 13 If the door does not close, cut power supply and restore it once the door is fully closed. Launch a new teach-in (closed door). 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 13 of 16 Page 13 of 16...
  • Page 14: Technical Specifications

    ISO 13849-1 Pl “d”/ CAT2; IEC 60825-1; IEC 60950-1; IEC 61000-6-2; IEC 61000-6-3; IEC 62061 SIL 2 Specifications are subject to change without prior notice. All values measured in specific conditions. Page 14 of 16 Page 14 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...
  • Page 15: Appendix 1: Door Height/Width Combinations

    APPENDIX 1: DOOR HEIGHT/WIDTH COMBINATIONS 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612 Page 15 of 16 Page 15 of 16...
  • Page 16 Verify that all appropriate industry signage and warning labels are in place. Tech Support & Customer Service: 1-800-523-2462 General Tech Questions: techservices-us@BEAsensors.com | Tech Docs: www.BEAsensors.com Page 16 of 16 Page 16 of 16 75.5947.04 LZR-FLATSCAN SW 20200612 75.5947.04 LZR-FLATSCAN SW 20200612...