Ip66/nema 4x pumps
Table of Contents

Advertisement

Watson-Marlow 520DuN IP66/NEMA 4X User Manual
Pump specifications
Control range (turndown ratio)
Supply voltage/frequency
Maximum voltage fluctuation
Installation category
(overvoltage category)
Power consumption
Full load current
Eprom version
Enclosure rating
Pumphead options
Operating temperature range
Storage temperature range
Maximum altitude
Humidity (non-condensing)
Pollution degree
* Protect from prolonged UV exposure.
Note: 520 drive models are C ETL US listed. Cert to std CAN/CSA C22.2 No 1010-
92. Conforms to std UL 61010A-1 April 30, 2002.
Note: 520 drive models have been tested in accordance with BS EN 61000-6-2:
2001 (EN 61000-4-4) Fast Transient and Burst Tests to Industrial limits – ie: Level 3:
2kV.
0.1-360rpm (3,600:1)
100-120V/200-240V 50/60Hz 1ph
±10% of nominal voltage.
A well regulated electrical mains supply
is required along with cable connections
to the best practice of noise immunity
<0.6A at 230V; <1.25A at 115V
Accessible through pump software
IP66 to BS EN 60529;
NEMA 4X to NEMA 250 *
520R, 501RL, 313, 314, 505L,
505BA, 505CA, 314MC, 318MC
5C to 40C, 41F to 104F
-40C to 70C, -40F to 158F
80% up to 31C, 88F, decreasing linearly
to 50% at 40C, 104F
II
135VA
2,000m, 6,560ft
2
13