What To Do If - Olsberg 23/727 Instruction

Kaminofen pilas
Table of Contents

Advertisement

Available languages

Available languages

What to do if ...?

... the stove doesn't draw properly?
● Is the chimney or the stovepipe not tight?
● Has the chimney been incorrectly designed?
● Is the external temperature too high?
● Are the doors of other fireplaces connected to the
chimney open?
... the room doesn't get hot?
● Is the heating requirement too high?
● Is the waste gas pipe blocked?
● Is the combustion air supply been closed?
● Is the chimney draught too low?
● Is the wood used as fuel not dry?
... the stove gives off too much heat?
● Is the combustion air supply open too wide?
● Is the delivery pressure too high?
... the grate becomes damaged or slags are formed?
● The stove was overloaded.
● The ash pan was not emptied in good time.
... a fault occurs?
● Do not add any more fuel.
● Do not open the combustion chamber door.
● Allow the fire in the chimney to burn itself out in a con-
trolled fashion.
... the chimney catches fire?
● Minimize the air supply to the stove and call the fire
department.
● Inform the chimney sweep.
● Have a professional determine the cause?
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

23/726

Table of Contents