WK Series
How to Install the Unit
1
To prevent vibration and noise, make sure the unit
is installed securely and firmly.
2
Install the unit where the sunlight does not shine
directly on the unit.
3
The outside of the cabinet must extend outward for
at least 305mm and there should be no obstacles,
such as a fence or wall, within 508mm from the back
of the cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the
structure.
4
Install the unit a little slanted so the back is slightly lower than the front (about 12.7mm).
This will force condensed water to flow to the outside.
5
Install the unit with the bottom about 762mm ~ 1524mm above the floor level.
Window Requirements
: All supporting parts should be secured to firm wood, masonry, or metal.
NOTICE
• This unit is designed for installation in standard double
hung windows with actual opening widths from
584mm to 914mm.
• The top and bottom window sash must open sufficiently
to allow a clear vertical opening of 381mm from the
bottom of the upper sash to the window stool.
Awning
Cooled air
584mm to 914mm
381mm
Stool
min.
(With frame curtain)
Interior wall
510 mm
min.
(Without frame curtain)
Hardware Installation
Fence
Heat
radiation
About
12.7mm
Over
508mm
Offset
12.7mm to 31.8mm
Sill
Exterior
Owner's Manual 13