3.6. Start-up

Once the connections have been made and before
running the pump the leaktightness of joints must be
checked. Switch on the water supply to the pump and
eliminate any air left inside the pump by using the
bleed devices on the pump.
Start up the pump. Press "Start" on the electrical
panel and press the pneumatic pump-start button.
The pipe valves must be fully open during
!
pump operation and must never be closed
while it is running. Shutting off or quickly
reducing the passage of water can give rise
to pressure surges that could lead to
equipment breakage.
Leave the pump running for a few minutes and check
that the equipment has been correctly installed.

4. INSTRUCTIONS FOR USE.

4.1. Starting / Stopping the pump.

The pump will come into operation when the
pneumatic pushbutton(23) is pressed, and will stop if
it is pressed again.

4.2. Air regulator.

Turn the regulating button (21) to regulate the air
bubbles.

4.3. Flow regulator.

The water flow can be adjusted by turning the
discharge pipe to the right or to the left.
The direction of the water jet can also be adjusted
using the discharge pipe knuckle-joint system.
Maximum
Flow

5. REPAIR AND MAINTENANCE.

5.1. General considerations.

Check the air-passage filter (22) and if necessary
clean out any dirt or insects.

5.2. Overwintering

The installation must be protected in winter against
the potential risk of freezing. The following operations
will have to be carried out:
- Disconnect the pump from the electricity supply.
- Drain the water from inside the pump, using the
drain plug.
After the overwintering period refit the components
removed and, before running the pump:
- Check manually to ensure that the pump motor shaft
rotates, by rotating the fan.
- Check the connections for leaktightness.
Correct operation of the installation must be checked
during the first few minutes of running.
31
Minimum
Medium
Flow
Flow