RCO NoKey Force Series Installing And Operating

RCO NoKey Force Series Installing And Operating

With r-card 5000

Advertisement

NoKey Force
Installing and Operating
Installing and operating NoKey force:
K01
K03
KC03 Oval cylinder
KC03 Round cylinder
KC02
April 2019
© 2019 RCO Security AB. All rights reserved.
R-CARD 5000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NoKey Force Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RCO NoKey Force Series

  • Page 1 R-CARD 5000 NoKey Force Installing and Operating Installing and operating NoKey force: • • KC03 Oval cylinder • KC03 Round cylinder • KC02 • April 2019 © 2019 RCO Security AB. All rights reserved.
  • Page 2: Table Of Contents

    Contents Safety and environment............................3 General..................................4 Installing NoKey force with round cylinders ....................5 Checking the placement of the lock housing; altering the length of the square pin ... 6 Adjusting the handle hole and/or recess for the lock housing ........... 8 Adapting for left-hinged doors .......................
  • Page 3: Safety And Environment

    The product meets all applicable regulations in accordance with RoHS/WEEE and REACH. RoHS/WEEE The product is marked with the crossed-out waste bin, and can be sent to RCO for Recycling recycling or sent for recycling in accordance with local provisions.
  • Page 4: General

    KC02   Recommendation: Download the information sheet Swedish) from RCO:s website! The info Låshus per modell sheet uses a matrix to illustrate suitable lock housings for each NoKey model. Some lock A butterfly adapter is required with this type of cylinder housings require a butterfly adapter to prevent the knob pin from jamming.
  • Page 5: Installing Nokey Force With Round Cylinders

    NoKey Force – Installing and Operating Installing NoKey force with round cylinders Installing NoKey force with round cylinders When installing NoKey force KC02 or KC03 together with a round cylinder, there is nothing fixing the unit’s upper section to the door leaf, as with the cylinder ring when installing with an oval cylinder.
  • Page 6: Checking The Placement Of The Lock Housing; Altering The Length Of The Square Pin

    Note: If the door leaf is 39 mm or thinner, a spacer plate must be fitted to the rear of the inner unit. To be ordered from RCO Security (item no 20 180 815). Hold it against the door leaf when placing the gauge and defining the length of the square pin.
  • Page 7 NoKey Force – Installing and Operating Checking the placement of the lock housing Cut the square pin to the correct length as per the mark. Make sure the cut is at a right angle. Smooth off the cut face with a suitable tool.
  • Page 8: Adjusting The Handle Hole And/Or Recess For The Lock Housing

    NoKey Force – Installing and Operating Adjusting the handle hole and/or recess for the lock housing 2 Adjusting the handle hole and/or recess for the lock housing If the gauge does not go into the handle hole, or if there is not enough space for the cable, the necessary adjustments will have to be made.
  • Page 9: Adapting For Left-Hinged Doors

    NoKey Force – Installing and Operating Adapting for left-hinged doors 3 Adapting for left-hinged doors The lock is set for right-hinged doors. Use the following process to adapt it for left-hinged doors. The repositioning is achieved on the outer unit by turning the handle and lock mechanism.
  • Page 10: Models K01 And K03, Without Cylinders

    NoKey Force – Installing and Operating Installing the outer and inner unit 4 Installing the outer and inner unit This describes the installation of an outer unit without lock cylinder together with an inner unit Models K01 and K03, without cylinders without a knob.
  • Page 11 NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) The spacer plate is screwed on to the rear of the inner unit with the Spacer plate accompanying screw (Torx T15).
  • Page 12 NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm Take care to ensure the threads are not damaged.
  • Page 13 NoKey Force – Installing and Operating Installing the outer and inner unit Cut the upper lock screws as follows: Min = door thickness + 6 mm 4.11 Max = door thickness + 11 mm Take care to ensure the threads are not damaged.
  • Page 14 NoKey Force – Installing and Operating Installing the outer and inner unit Check the handle function from the outside. The lock is always unlocked 4.14 until it is put into operation. If something is sticking, this could be because: • the lock or square pin does not have enough clearance against the door or lock housing.
  • Page 15 NoKey Force – Installing and Operating Installing the outer and inner unit Refit the cover on the inner unit. Ensure the handle is inserted towards the 4.17 square pin. Re-insert the four screws for the cover and tighten. 4.18 (Allen 3 mm) Replace the battery cover and tighten the screws on the underside.
  • Page 16: Model Kc03, With Cylinder On The Outside Of The Door

    NoKey Force – Installing and Operating Installing the outer and inner unit This describes the installation of an outer unit with cylinder together with an inner unit with a Model KC03, with cylinder on the outside of the door knob. For installation of NoKey force KC02 go to page 23! To simplify the process for the installer, the lock is always unlocked until it is in operation.
  • Page 17 NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) The spacer plate is screwed on to the rear of the inner unit with the Spacer plate accompanying screw (Torx T15).
  • Page 18 NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm Take care to ensure the threads are not damaged.
  • Page 19 NoKey Force – Installing and Operating Installing the outer and inner unit When the lock cylinder is fitted, you must compensate for the thickness of 4.11 the cover (17 mm) with a suitable cylinder extender. Fit the lock cylinder and extender to the lock housing.
  • Page 20 NoKey Force – Installing and Operating Installing the outer and inner unit Remove the transport protection by pulling it out straight, not to the side. 4.13 Check the handle function from the outside. The lock is always unlocked 4.14 until it is put into operation. If something is sticking, this could be because: •...
  • Page 21 NoKey Force – Installing and Operating Installing the outer and inner unit Fold the cable double and place it under the load holder. 4.16 Insert the batteries (5 x AA) into the battery compartment. To define the length of the knob pin: A Insert the pin towards the lock 4.17 housing until it reaches the...
  • Page 22 NoKey Force – Installing and Operating Installing the outer and inner unit Refit the cover on the inner unit. Ensure the handle is inserted towards 4.18 the square pin and the handle towards the lock housing. Re-insert the four screws for the cover and tighten.
  • Page 23: Model Kc02, With Round Cylinders On The Inside And Outside Of The Door

    Model KC02, with round cylinders on the inside and outside of the door Tips: Installation of KC02 is shown on RCO's YouTube channel. To simplify the process for the installer, the lock is always unlocked until it is in operation.
  • Page 24 NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) Spacer plate The spacer plate is screwed on to the rear of the inner unit with the accompanying screw (Torx T15).
  • Page 25 NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. The smaller square pin should be inserted in the correct hole. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm...
  • Page 26 NoKey Force – Installing and Operating Installing the outer and inner unit Remove the transport protection by pulling it out straight, not to the side. 4.12 Check the handle function from the outside. The lock is always unlocked 4.13 until it is put into operation. If something is sticking, this could be because: •...
  • Page 27 NoKey Force – Installing and Operating Installing the outer and inner unit Fold the cable double and place it under the load holder. 4.15 Insert the batteries (5 x AA) into the battery compartment. Refit the cover on the inner unit. 4.16 Ensure the handle is inserted towards the square pin and the handle towards...
  • Page 28: The Latch Bolt Can Protrude

    NoKey Force – Installing and Operating Installing the outer and inner unit The latch bolt can protrude Tolerance: When the handle is pressed, the latch bolt can stick out 1–2 mm.
  • Page 29: General

    NoKey Force – Installing and Operating Programming the code lock 5 Programming the code lock In order to perform any programming, the unit must be set to programming mode. This can be done General by entering the system code. The default system code is 1234. Recommendation: Change the factory-set system code with your own system code as soon as possible.
  • Page 30: Changing Access Codes

    NoKey Force – Installing and Operating Programming the code lock 1. Set the unit into programming mode by entering the system code. Changing access codes 2. Press 1 (menu selection), then #. 3. Enter the memory position (1–98) of the code to be changed. End with #. 4.
  • Page 31: Adjust How Long The Door Stays Unlocked

    NoKey Force – Installing and Operating Programming the code lock The lock opening time can be set between 1 and 9 seconds, or to 0 to get 30 seconds. The standard Adjust how long the door stays unlocked time is 3 seconds. 1.
  • Page 32: Entering A Code For Activating/Deactivating Zero Opening

    NoKey Force – Installing and Operating Programming the code lock Zero opening means that the door can be opened by simply pressing 0 instead of entering a code in Entering a code for activating/deactivating zero opening the normal way. Here is how to specify a code to be used to activate or deactivate zero opening. The code itself will not work for unlocking.
  • Page 33: Factory Resetting

    NoKey Force – Installing and Operating Programming the code lock Factory settings: Factory resetting • System code: 1234 • Battery warning with sound: On • Lock opening time: 3 secs. • Sound on lock opening: Off • Code attempt limitation: Off •...
  • Page 34: Appendix 1: Signals In Nokey Force

    NoKey Force – Installing and Operating Appendix 1: Signals in NoKey force Appendix 1: Signals in NoKey force NoKey force has a green LED lamp and a sound that tell you the unit’s status. Signals are used both during programming and during daily use. Only the left lamp is used in NoKey force. LED lamp Signal Cause...
  • Page 35: Appendix 2: Specifications

    NoKey Force – Installing and Operating Appendix 2: Specifications Appendix 2: Specifications Weight Dimensions Width Height Depth Outer unit 67 mm 260 mm 17 mm 1 160 g Inner unit 68 mm 272 mm 25 mm 1 440 g Power supply 5 pcs.
  • Page 36 NoKey Force – Installing and Operating Table for your own codes Table for your own codes Code Code Name/use Code Name/use Code position position...
  • Page 37 NoKey Force – Installing and Operating Table for your own codes Code Code Name/use Code Name/use Code position position (99) Code for activating/deactivating zero opening (see page 32): – System code:...

Table of Contents