Contents Safety and environment............................3 General..................................4 Installing NoKey force with round cylinders ....................5 Checking the placement of the lock housing; altering the length of the square pin ... 6 Adjusting the handle hole and/or recess for the lock housing ........... 8 Adapting for left-hinged doors .......................
The product meets all applicable regulations in accordance with RoHS/WEEE and REACH. RoHS/WEEE The product is marked with the crossed-out waste bin, and can be sent to RCO for Recycling recycling or sent for recycling in accordance with local provisions.
KC02 Recommendation: Download the information sheet Swedish) from RCO:s website! The info Låshus per modell sheet uses a matrix to illustrate suitable lock housings for each NoKey model. Some lock A butterfly adapter is required with this type of cylinder housings require a butterfly adapter to prevent the knob pin from jamming.
NoKey Force – Installing and Operating Installing NoKey force with round cylinders Installing NoKey force with round cylinders When installing NoKey force KC02 or KC03 together with a round cylinder, there is nothing fixing the unit’s upper section to the door leaf, as with the cylinder ring when installing with an oval cylinder.
Note: If the door leaf is 39 mm or thinner, a spacer plate must be fitted to the rear of the inner unit. To be ordered from RCO Security (item no 20 180 815). Hold it against the door leaf when placing the gauge and defining the length of the square pin.
Page 7
NoKey Force – Installing and Operating Checking the placement of the lock housing Cut the square pin to the correct length as per the mark. Make sure the cut is at a right angle. Smooth off the cut face with a suitable tool.
NoKey Force – Installing and Operating Adjusting the handle hole and/or recess for the lock housing 2 Adjusting the handle hole and/or recess for the lock housing If the gauge does not go into the handle hole, or if there is not enough space for the cable, the necessary adjustments will have to be made.
NoKey Force – Installing and Operating Adapting for left-hinged doors 3 Adapting for left-hinged doors The lock is set for right-hinged doors. Use the following process to adapt it for left-hinged doors. The repositioning is achieved on the outer unit by turning the handle and lock mechanism.
NoKey Force – Installing and Operating Installing the outer and inner unit 4 Installing the outer and inner unit This describes the installation of an outer unit without lock cylinder together with an inner unit Models K01 and K03, without cylinders without a knob.
Page 11
NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) The spacer plate is screwed on to the rear of the inner unit with the Spacer plate accompanying screw (Torx T15).
Page 12
NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm Take care to ensure the threads are not damaged.
Page 13
NoKey Force – Installing and Operating Installing the outer and inner unit Cut the upper lock screws as follows: Min = door thickness + 6 mm 4.11 Max = door thickness + 11 mm Take care to ensure the threads are not damaged.
Page 14
NoKey Force – Installing and Operating Installing the outer and inner unit Check the handle function from the outside. The lock is always unlocked 4.14 until it is put into operation. If something is sticking, this could be because: • the lock or square pin does not have enough clearance against the door or lock housing.
Page 15
NoKey Force – Installing and Operating Installing the outer and inner unit Refit the cover on the inner unit. Ensure the handle is inserted towards the 4.17 square pin. Re-insert the four screws for the cover and tighten. 4.18 (Allen 3 mm) Replace the battery cover and tighten the screws on the underside.
NoKey Force – Installing and Operating Installing the outer and inner unit This describes the installation of an outer unit with cylinder together with an inner unit with a Model KC03, with cylinder on the outside of the door knob. For installation of NoKey force KC02 go to page 23! To simplify the process for the installer, the lock is always unlocked until it is in operation.
Page 17
NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) The spacer plate is screwed on to the rear of the inner unit with the Spacer plate accompanying screw (Torx T15).
Page 18
NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm Take care to ensure the threads are not damaged.
Page 19
NoKey Force – Installing and Operating Installing the outer and inner unit When the lock cylinder is fitted, you must compensate for the thickness of 4.11 the cover (17 mm) with a suitable cylinder extender. Fit the lock cylinder and extender to the lock housing.
Page 20
NoKey Force – Installing and Operating Installing the outer and inner unit Remove the transport protection by pulling it out straight, not to the side. 4.13 Check the handle function from the outside. The lock is always unlocked 4.14 until it is put into operation. If something is sticking, this could be because: •...
Page 21
NoKey Force – Installing and Operating Installing the outer and inner unit Fold the cable double and place it under the load holder. 4.16 Insert the batteries (5 x AA) into the battery compartment. To define the length of the knob pin: A Insert the pin towards the lock 4.17 housing until it reaches the...
Page 22
NoKey Force – Installing and Operating Installing the outer and inner unit Refit the cover on the inner unit. Ensure the handle is inserted towards 4.18 the square pin and the handle towards the lock housing. Re-insert the four screws for the cover and tighten.
Model KC02, with round cylinders on the inside and outside of the door Tips: Installation of KC02 is shown on RCO's YouTube channel. To simplify the process for the installer, the lock is always unlocked until it is in operation.
Page 24
NoKey Force – Installing and Operating Installing the outer and inner unit If the door is thinner than 39 mm, a spacer plate is needed on the rear of the inner unit (see page 6.) Spacer plate The spacer plate is screwed on to the rear of the inner unit with the accompanying screw (Torx T15).
Page 25
NoKey Force – Installing and Operating Installing the outer and inner unit Insert the unit with the hex pin and square pin to the lock housing and the outer unit. The smaller square pin should be inserted in the correct hole. Cut the lower lock screws as follows: Min = door thickness + 18 mm Max = door thickness + 26 mm...
Page 26
NoKey Force – Installing and Operating Installing the outer and inner unit Remove the transport protection by pulling it out straight, not to the side. 4.12 Check the handle function from the outside. The lock is always unlocked 4.13 until it is put into operation. If something is sticking, this could be because: •...
Page 27
NoKey Force – Installing and Operating Installing the outer and inner unit Fold the cable double and place it under the load holder. 4.15 Insert the batteries (5 x AA) into the battery compartment. Refit the cover on the inner unit. 4.16 Ensure the handle is inserted towards the square pin and the handle towards...
NoKey Force – Installing and Operating Installing the outer and inner unit The latch bolt can protrude Tolerance: When the handle is pressed, the latch bolt can stick out 1–2 mm.
NoKey Force – Installing and Operating Programming the code lock 5 Programming the code lock In order to perform any programming, the unit must be set to programming mode. This can be done General by entering the system code. The default system code is 1234. Recommendation: Change the factory-set system code with your own system code as soon as possible.
NoKey Force – Installing and Operating Programming the code lock 1. Set the unit into programming mode by entering the system code. Changing access codes 2. Press 1 (menu selection), then #. 3. Enter the memory position (1–98) of the code to be changed. End with #. 4.
NoKey Force – Installing and Operating Programming the code lock The lock opening time can be set between 1 and 9 seconds, or to 0 to get 30 seconds. The standard Adjust how long the door stays unlocked time is 3 seconds. 1.
NoKey Force – Installing and Operating Programming the code lock Zero opening means that the door can be opened by simply pressing 0 instead of entering a code in Entering a code for activating/deactivating zero opening the normal way. Here is how to specify a code to be used to activate or deactivate zero opening. The code itself will not work for unlocking.
NoKey Force – Installing and Operating Programming the code lock Factory settings: Factory resetting • System code: 1234 • Battery warning with sound: On • Lock opening time: 3 secs. • Sound on lock opening: Off • Code attempt limitation: Off •...
NoKey Force – Installing and Operating Appendix 1: Signals in NoKey force Appendix 1: Signals in NoKey force NoKey force has a green LED lamp and a sound that tell you the unit’s status. Signals are used both during programming and during daily use. Only the left lamp is used in NoKey force. LED lamp Signal Cause...
NoKey Force – Installing and Operating Appendix 2: Specifications Appendix 2: Specifications Weight Dimensions Width Height Depth Outer unit 67 mm 260 mm 17 mm 1 160 g Inner unit 68 mm 272 mm 25 mm 1 440 g Power supply 5 pcs.
Page 36
NoKey Force – Installing and Operating Table for your own codes Table for your own codes Code Code Name/use Code Name/use Code position position...
Page 37
NoKey Force – Installing and Operating Table for your own codes Code Code Name/use Code Name/use Code position position (99) Code for activating/deactivating zero opening (see page 32): – System code:...
Need help?