Summary of Contents for Inficon VSA100A

  • Page 1 Konformitätserklärung / incl. Declaration of Conformity tina29d2-b VSA100A Artikelnummer / Part Number 399-001 Vacuum Switch...
  • Page 2: Table Of Contents

    ......6 Service bei INFICON ....6 Produkt entsorgen .
  • Page 3: Beschreibung

    Beschreibung Allgemeine Angaben 1.1.1 Verwendungszweck Der Vacuum Switch VSA100A dient als Druckschalter in Den Vacuum Switch VSA100A bitte sofort auspacken, Vakuumsystemen. Er wird z.B. eingesetzt, um beim auch wenn er zu einem späteren Zeitpunkt in Betrieb Belüften von Vakuumanlagen mit einem Schutzgas die genommen wird.
  • Page 4: Wirkungsweise

    Elektrischer Anschluß Standardleitung 3 m Ausstattung Vakuumanschluß DN 16 KF 1.4.1 Lieferumfang Schutzart IP 44 Vacuum Switch VSA100A Medienberührende Werkstoffe kpl. mit Leitung 3 m Artikelnummer 399-001 Edelstahl 1.4305, 1.4310 Edelstahl 1.4300 PTFE-beschichtet Gebrauchsanleitung tina29d2 EPDM Internes Volumen 2 cm...
  • Page 5: Inbetriebnahme

    Dieser beruht i.a. nicht auf einer Leckage des VSA100A, sondern auf Permeation des Heliums durch die EPDM-Membrane. Vakuumanschluß DN16 KF Der VSA100A wird mit einem Kleinflansch DN 16 KF an Ø 48.5 der Vakuumanlage verbunden. Abb. 1 Maßzeichnung VSA100A Der VSA100A sollte vorzugsweise auf dem Flansch ste- hend montiert werden.
  • Page 6: Wartung

    Der VSA100A ist wartungsfrei. Die elektrischen Anschlußklemmen und die Zugentla- stung sind nach Abschrauben der Kreuzschlitzschrau- ben und Abklappen der Haube zugänglich. Die Kontakte sind am VSA100A mit 1, 2 und 3 bezeich- Service bei INFICON net (siehe Kontaktbelegung Abb. 2). Vorsicht Kontaminierte Produkte (z.B.
  • Page 7: Produkt Entsorgen

    Umweltschä- den verursachen. Umweltgefährdende Stoffe gemäss den örtlichen Vor- schriften entsorgen. Unterteilen der Bauteile Nach dem Zerlegen des Produkts sind die Bauteile ent- sorgungstechnisch in folgende Kategorien zu untertei- len: Kontaminierte Bauteile Kontaminierte Bauteile (radioaktiv, toxisch, ätzend, tina29d2-b (2004-10) VSA100A.ga...
  • Page 8: Eg-Konformitätserklärung

    EG-Konformitätserklärung Im Sinne der Maschinenrichlinie 98/37/EG, Anhang IIb. Artikelnummern Hiermit erklären wir, INFICON, daß die nachfolgend 399-001 bezeichneten Produkte aufgrund ihrer Konzipierung und Normen Bauart sowie in der von uns in Verkehr gebrachten Aus- Harmonisierte und internationale / nationale Normen führung den einschlägigen grundlegenden Sicherheits-...
  • Page 9: Kontaminationserklärung

    (2004-10) VSA100A.ga...
  • Page 10: The English Operating Manual Starts On Page

    Maintenance ..... . . 14 Service at INFICON ....14 Disposal .
  • Page 11: Description

    Description General 1.1.1 Intended Use The Vacuum Switch VSA100A is used as a pressure Unpack the Vacuum Switch VSA100A immediately after switch in vacuum systems. It is used e.g. to automatical- delivery, even if it is to be put into operation at a later ly interrupt the gas supply when venting vacuum sy- date.
  • Page 12: Function

    Equipment Vacuum connection DN 16 KF 1.4.1 Scope of delivery Protection type IP44 Vacuum Switch VSA100A Materials in contact with the medium complete with cable, 3 m Part Number 399-001 Stainless steel 1.4305, 1.4310 Stainless steel 1.4300 PTFE coated Operating Manual...
  • Page 13: Start-Up

    VSA100A, but is permeation of helium through the EPDM diaphragm. Vacuum Connection DN16 KF The VSA100A is connected to the vacuum system via a Ø 48.5 DN 16 KF small flange. Fig. 1 Dimensional diagram VSA100A The VSA100A should preferably be mounted standing on its flange.
  • Page 14: Maintenance

    The electrical connection terminals and the strain relief are accessible after unscrewing the cross head screws and folding out the cap. Service at INFICON The contacts at the VSA100A are marked 1, 2 and 3 (see contact assignment Fig. 2). Warning Contaminated products (e.g. radioac- tive, toxic, caustic or microbiological The supply line has to be fuse-protected with max.
  • Page 15: Disposal

    Dispose of such substance in accordance with the rele- vant local regulations. Separating the components After disassembling the product, separate its compo- nents according to the following criteria: Contaminated components Contaminated components (radioactive, toxic, caustic or biological hazard etc.) must be decontaminated in tina29d2-b (2004-10) VSA100A.ga...
  • Page 16: Eec Declaration Of Conformity

    Directive relating to machinery Part Number 98/37/EG, Appendix IIb. 399-001 We -INFICON - herewith declare that the products defined Standards below meet the basic requirements regarding safety and Harmonized and international / national standards and health of the relevant EEC directives by design, type and specifications: the versions which are brought in to circulation by us.
  • Page 17: Declaration Of Contamination

    (2004-10) VSA100A.ga...
  • Page 18 SINGAPORE TAIWAN Due to INFICON s continuing program of product improvements, specifications are subject to change without notice. w w w. i n f i c o n . c o m Vi s i t o u r w e b s i t e f o r c o n t a c t i n f o r m a t i o n a n d o t h e r s a l e s o ff i c e s w o r l d w i d e .