  • Page 1 Operating M Manual Incl. EU Declara ation of Conform mity Vacu um S Switch h VSA100 tina29e1 (2017 7-05)
  • Page 2: Product Identification

    3 mbar below atmospheric pressure. Unpacking and Checking Unpack the Vacuum Switch VSA100A immediately after delivery, even if it is to be put into operation at a later date. Before doing so, examine the shipping container for any external damage. Then completely remove the packaging materials.
  • Page 3: Table Of Contents

    2 Technical Data 3 Installation 3.1 Vacuum Connection 3.2 Electrical Connection 3.3 Start up 4 Maintenance 5 Returning the Product 6 Disposal EU Declaration of Conformity For cross-references within this document, the symbol (→  XY) is used. tina29e1 (2017-05) VSA100A.om...
  • Page 4: Safety

    Communicate the safety instructions to other users. 1.4 Liability and Warranty INFICON assumes no liability and the warranty becomes null and void if the end- user or third parties • disregard the information in this document •...
  • Page 5: Technical Data

    DN 16 KF Protection type IP 44 Materials in contact with the medium stainless steel 1.4305, 1.4310 stainless steel 1.4300 PTFE coated EPDM Internal volume 2 cm Weight 315 g Dimensions [mm] Fig. 1 Dimensional diagram VSA100A tina29e1 (2017-05) VSA100A.om...
  • Page 6: Installation

    3 Installation The VSA100A is connected to the vacuum system via a DN 16 KF small flange. 3.1 Vacuum Connection The VSA100A should preferably be mounted standing on its flange. Inclined mounting is also permissible, including the horizontal position. Downward installa- tion is not permissible because in such a case condensate may collect in the pres- sure switch.
  • Page 7: Maintenance

    (Form under www.inficon.com). Products that are not clearly declared as "free of harmful substances" are de- contaminated at the expense of the customer. When returning a product to INFICON, put it in a tight and impact resistant package. tina29e1 (2017-05) VSA100A.om...
  • Page 8: Disposal

    Contaminated components (radioactive, toxic, caustic, or biological hazard etc.) must be decontaminated in accordance with the relevant national regulations, separated according to their materials, and recycled. Other components Such components must be separated according to their materials and recycled. tina29e1 (2017-05) VSA100A.om...
  • Page 9: Eu Declaration Of Conformity

    EU Declaration of Conformity We, INFICON, hereby declare that the equipment mentioned below complies with the provisions of the following directives: • 2014/35/EU, OJ L 96/357, 29.3.2014 (Low Voltage Directive; Directive relating to electrical equipment designed for use within certain voltage limits) •...
  • Page 10 Notes tina29e1 (2017-05) VSA100A.om...
  • Page 11 Notes tina29e1 (2017-05) VSA100A.om...
  • Page 12 LI–9496 Balzers Liechtenstein Tel +423 / 388 3111 Fax +423 / 388 3700 reachus@inficon.com Original: German tina29d1 (2017-05) www.inficon.com t i na29e1...