Download Print this page

Sanxin EC5 Operation Manual

Conductivity tester, conductivity/tds/salinity/temp.

Advertisement

Quick Links

EC5 Conductivity Tester
Conductivity/TDS/Salinity/Temp.
Operation Manual
Shanghai San-Xin Instrumentation Inc.

Advertisement

loading
Need help?

Need help?

Do you have a question about the EC5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanxin EC5

  • Page 1 EC5 Conductivity Tester Conductivity/TDS/Salinity/Temp. Operation Manual Shanghai San-Xin Instrumentation Inc.
  • Page 2: Battery Installation

    EC5 Conductivity Tester Operation Manual 1. Battery Installation Please install batteries according to the following steps. Please note polarity: “+” (anode) is upward; “-” (cathode) is downward. ﹣ ﹣ ﹣ ﹣ ① Pull the battery cap up ② Push the battery cover along to the direction of arrow ③...
  • Page 3 3. Conductivity Calibration 3.1. Press key to enter in conductivity measurement mode, rinse the probe in pure water and dry it. 3.2. Fill certain amount (about half volume of the calibration bottle) of 1413μS and 12.88mS standard solution in separate calibration bottles; 3.3.
  • Page 4 5.2. The tester has been calibrated in factory. Generally, user can use the tester directly or users can test conductivity standard solutions first. If the error is big, then calibration is needed. 5.3. Temperature compensation factor: The default setting of the temperature compensation ℃...
  • Page 5: Parameter Setting

    Parameter Setting 6.1. Parameter setting method When turned off, long press to enter parameter setting→Short press to switch P1-P2…P7→Short Press , parameter flickering→Short press to choose parameter→ Short press to confirm parameter→Long press to return to measurement mode. 6.2. Setting schedule Symbol Parameter Setting Contents Code...
  • Page 6 e) Salinity and temperature unit (P5 and P6) ℃ ℉ ℃. Salinity unit: ppt and mg/L, Temperature unit: . Factory default setting is ppt and f) Factory default setting (P7) Select “Yes” to recover instrument calibration to theoretical value, parameter setting return to initial value.
  • Page 7 8. Other Specifications Ultra clear STN LCD. 180°Viewing angle Blue: Measurement. Green: Calibration. Red: Alarm Reading lock HOLD Replace batteries when icon blinks Low battery reminder Automatic power-off 8 minutes after last key press Waterproof rating IP67 floatable Power DC3V, AAA batteries×4 Battery life Continuous operation>200 hours Tester: 40×40×178mm/133g;...
  • Page 8 Shanghai San-Xin Instrumentation, Inc. Add: 4/F. Building No.16, No. 481 Guiping Road, Shanghai, China. 200233 Tel: +86-21-63362480 Fax: +86-21-64956880 Website: www.shsan-xin.com E-mail: wxmab@shsan-xin.com...