Page 2
Warning Dear users: Thanks for choosing our company’s product, in order to fully make use of the products, we sincerely suggest follow: ◆◆Please read the instruction in detail and keep it well for further reading and consulting. ◆◆Please follow the instruction to fit and operate the machine correctly. ◆◆Please do not remove and change any accessories of the machine.
Page 3
Please read the NOTES carefully before use Machine. 1.Please make sure the tank is filled with water before start machine . 2.Please put at least two pieces membranes on treat area before start treatment . 3.Please clear the filter in time .otherwise it will cause residual liquid to be poured into the machine and burned out parts .
Page 4
Phone:(+86) 189 -487-55929 Tel: 0755-86368500 Email: sales@mychway.com 1. Introduction to Manual 1.1 Purpose This instructions for use manual provides a description of the system components, its controls and displays, instructions for its operation, and other equipment information important to the user Warning: Do Not operate this machine before reading this manual thoroughly.
Page 5
Chapter 1: Safety Warnings I. Electricity & Machinery Safety 1.The machine is 110V-220V.so you can use it any Country you want . 2. Please keep the voltage at stable condition. II. Contraindication Safety 1. People with heart disease, high blood pressure, or configured cardiac Pacemaker. 2.
Chapter 2: Specifications and Installation I .Working Condition Using at normal temperatures and pressure. Please do not stay in too cold, too hot, too dry and too wet. II.Technical Specification Rated input voltage:AC220V-240V 50HZ /AC110V-120V 60Hz Rated input power:350VA Cool cold slimming Vacuum Power: Up to 200W Cooling device output temperature: 5~ -10℃...
RF frequency: 3MHz RF power: up to 150W RF for FACE RF frequency: 3MHz RF power: up to 30W Chapter 2: Installation How to input water A,Connect the funnel to the input water hole; - 7 -...
B,Take off the blue rubber on the overflow hole; C,Input water with pipe; D,The water is full after the water overflows from the overflow hole. Then put on the blue rubber to the overflow hole. E,The drainage hole is to make out the water. Chapter 4: Operation 1.
Page 9
Single function interface in Page 2 Description: Cryolipolysis 1# and Cryolipolysis 2# stands for the 2 Cryo handles. "Work time" refers to the time of operation, which can be set as needed. "Temperature" refers to freezing temperature, e.g. 0℃ , -5℃ . D.
Page 10
Note: it is the temperature controller. If the temperature is too high, the machine will stop itself. It is the water controller. If the water is not full, or there is something wrong with the water circulation, the machine will stop itself in 5 seconds to protect the mac hine.
Page 11
4.After treatment, please pause the working, then switch off the power. Clean the spare parts and place them in original. 40K head : Single function interface in Page 4 1." " refers to the time of operation, which can be set as needed. 2."...
Page 12
5.Please click to come back to the main function interface. Body RF head : (5) Single function interface in Page 5 1." " refers to the time of operation, which can be set as needed. 2." " refers to RF heat Energy, which can be set as needed. 3.“...
Page 13
to start or pause function. 5.Please click to come back to the main function interface. Eye RF : (6) Single function interface in Page 6. 1." " refers to the time of operation, which can be set as needed. 2." "...
Page 14
mode, energy will reach the user setted slowly. Nor: professional mode, temperature will reach to the one u setted at once. 4. Please click to start or pause function. 5.Please click to come back to the main function interface. This bipolar RF handle have photon function, if you need, need photon on, need press this sign.
Page 15
Qualified antifreeze fluid is necessary to avoid frostbite during the treatment process when the temperature is reduced to 0 to -40 degrees. [Consumables, purchased by the user] Chapter 7. Treatment process Test the heart rate of the patient before the treatment [50-100 times per minute] Check the fat thickness.
After the treatment, skin injury, minor frostbite, or pigment may occur, pay attention to take good care of it. Chapter 9. Points for attention The machine must be operated by professionals. Do use antifreeze fluid. The patient cannot receive the treatment if he/she has following medical electronic equipment: - Implanted cardiac pacemakers or other implanted electronic devices;...
Page 17
Product name : Purchase date: deadline: Seller: Add.: Tel.: 18948755929 Customer: Add.: Tel.: Repair date: Reason of the f Repair content ault : Maintain list : - 17 -...