Electrical - Ryobi P3100 Operator's Manual

18 volt 45 watt hybrid soldering station
Hide thumbs Also See for P3100:
Table of Contents

Advertisement

Available languages

Available languages

DOUBLE INSULATION
Double insulation is a concept in safety in electric products,
which eliminates the need for the usual three-wire grounded
power cord. All exposed metal parts are isolated from the
internal metal components with protecting insulation. Double
insulated products do not need to be grounded.
WARNING:
The double insulated system is intended to protect the
user from shock resulting from a break in the product's
internal wiring. Observe all normal safety precautions to
avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should be
performed only by a qualified service technician. For service,
we suggest you return the product to your nearest autho-
rized service center for repair. Always use original factory
replacement parts when servicing.
ELECTRICAL CONNECTION
This is a hybrid product capable of operating on alternating
current (AC) through an extension cord or direct current (DC)
through a battery pack. If the product does not operate when
an extension cord or battery pack is installed, double-check
the power supply.
 To use alternating current, connect the product to a pow-
er supply that is 120 volts, AC only (normal household
current), 60 Hz.
 To use direct current, install a manufacturer-recom-
mended 18 volt battery pack only.
NOTE: Do not operate this product on direct current
through an extension cord. Doing so would cause a sub-
stantial voltage drop, which will cause a loss of power
and could cause the product to overheat.

ELECTRICAL

EXTENSION CORDS
When using a product at a considerable distance from a
power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When using this product outdoors, use an extension cord that
is designed for outside use. This type of cord is designated
with "WA" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or ex-
posed wires and cut or worn insulation.
**Ampere rating (on product data plate)
Cord Length
25´
50´
100´
**Used on 12 gauge - 20 amp circuit
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area. Po-
sition the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
this product. Failure to do so can result in serious per-
sonal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use a product with a dam-
aged cord since touching the damaged area could cause
electrical shock resulting in serious injury.
4 — English
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
Wire Size (A.W.G.)
16
16
16
16
16
16
16
16
14
7.1-12.0 12.1-16.0
16
14
14
14
14
12
12
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents