Summary of Contents for MYSTIC TAN MYSTIC MTM-2500HD
Page 1
MYSTIC HD SYSTEM (MTM-2500HD) EQUIPMENT MANUAL 2009 MT Industries, Inc. All rights reserved MT Industries, Inc. 8909 S. Freeway Drive, Suite 100 Macedonia, OH 44056 877.668.8826 12/8/2009...
MY S TIC HD BOO TH EQUIPMEN T MANUAL TABLE OF CONTENTS Equipment Se c tion 1 ( P ag e 3) Important Safeguards (Page 4-7) • Timer Installation • Stand-Alone Mode (Page 8) Network Installation (Page 9-10) Database Network (Page 10) Operating Your Mystic HD System •...
Page 3
SECTION 1 EQUIPMENT 2009 MT Industries, Inc. All rights reserved MT Industries, Inc. 8909 S. Freeway Drive, Suite 100 Macedonia, OH 44056 877.668.8826 12/8/2009...
Importan t Safeguards RE A D A N D U N D E RS T A N D AL L I NST R UCTIO NS BEFO RE USI NG THIS PRO DU CT When using electrical appliances, basic safety precautions must always be followed. Failure to follow all instructions listed below may result in fire, electrical shock or other serious personal injury.
Page 5
Important Safeguards (continued): Save These Instruc tions G ROU N D I N G I NST RU CTIO NS – This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electrical current.
Page 6
Insert Heater Control Cord A through this opening TOUCHPAD MAIN CONTROL ENABLE SESSION PURGE/RESET Main Power 115V GFI (US) 220V (International Only) 115V US (0r 2 2 0V In t e rn a tion al Only) GFC I P rot e c t ed. ...
Page 7
Importan t Safeguards (contin u ed): RE A D A N D U N D E RS T A N D AL L I NST R UCTIO NS BEFO RE USI NG THIS PRO DU CT Important - T he water supply to your boot h m ust be tur ned of f at the end of each day! The shutoff valve should be easily accessible and located at the end of your in-room water source.
Stand-Alone Mode The Stand-alone Mode gives you the ability to operate the Mystic HD® booth, without the use of a timer system. Sta nd-Alo ne Mode: TOUCHPAD MAIN CONTROL ENABLE SESSION PURGE/RESET Main Power Stand-Alone / Timer Toggle Slide Is Located Inside Of The Main Control Activati ng t he Stand- Alo ne Mode: To set the booth in the stand-alone mode, move the Slide Switch to stand-alone mode position.
Network Installation The Mystic HD System has the ability to connect to your T-Max or Intellitan Manager network. T-Max / I ntell itan T imer: T-Max Manager RJ22 Jack T-Max NETWORK “Daisy chain” to next booth. Start/Stop MAIN CONTROL Stand-Alone / Timer Slide Switch Located Inside...
Page 10
Network Installation The Mystic HD System has the ability to connect to your Database Network. D atabase Timer: MAIN CONTROL Room St a r t But ton Start/St T-max Timer relay Timer wires Timer Co n nectio n : The wall mounted main control box has two inputs marked ‘timer.’ Connect two low voltage wires from these inputs to the timer relay wires.
Ope ra t i ng Y our Mystic HD S yste m MagneTan™ Technology MagneTan™ is our patented process that uses the body's natural electrostatic properties to attract Tanning Solution to every exposed surface of the skin. When the solution passes through the spray nozzles in a Mystic HD System, the micro-myst particles are polarized, taking on the characteristics of "tiny magnets."...
“Welcome to Mystic Tan, i nsert yo ur prod uct cartridge, close the door and begi n yo ur pre-tan regimen. T he booth’s pre-heati ng cycle is now activated. Please wait u nti l t he pre-heat cycle is complete before entering t he boot h.
Operating your Mystic HD System (contin ued): Step 2 . C ustomer Inserts Cartridge: The customer will need to enter the booth and insert the product cartridge into the Sprayer receiver, then exit the booth and perform pre-tan preparation while the unit pre-heats. Step 3.
Operating your Mystic HD System (contin ued): Step 4. Sessio n Completed: Note: The Mystic HD System will automatically go into the D irty Bed Status mode. This is indicated by the flashing green light on the spray housing and on the Mini-Controller remote. The flash sequence is a repeat of two flashes and pause.
Page 15
Mystic System Touchpad Operation Manual enable -- Enables a session This button operates only if the manual enable mode is selected (by the switch inside controller). If the inside switch is “off” than enable will be activated by the T-max or other salon manager only. Manually purge the unit.
Equ ipment Troubleshooting Guide (contin ued) S y m pt o m Prob l e m Causes Re me dy Timer cord is The booth timer disconnected from Trace all wires to and from the timer the Timer Interface interface box. Reconnect. interface is not Cannot set a Tanning communicating...
Page 18
Equ ipment Troubleshooting Guide (contin ued) S y m pt o m Prob l e m Causes Re me dy Inspect receiver for obstruction with Cartridge not flashlight and remove with tweezers No spray inserted correctly if necessary. Instruct all customers during session.
SECTION 4 CONSUMER TROUBLESHOOTING 2009 MT Industries, Inc. All rights reserved MT Industries, Inc. 8909 S. Freeway Drive, Suite 100 Macedonia, OH 44056 877.668.8826 12/8/2009...
Page 20
Consumer Trouble Shooting Guide Prob l e m Causes Re me dy Hands have received too Try applying a heavier coat of blending cream much myst application. to the top of the hands to minimize absorption. Consumer’s TOPS of Try applying a heavier coat of blending cream hands are too dark.
Page 21
Skin may be too dry for rapid moisturizer prior to the tanning absorption. session. May have a history of a clinical Mystic Tan tanning results skin condition i.e. eczema, depend on the condition and psoriasis consistency of the skin. Using a shaving cream or UV Consumer’s tan is ‘blotchy’...