Download Print this page

Altinex Signal Management Solutions PNP515 Series User Manual

Customizable pop customizable pop‘n plug ‘n plug with custom tabletop with custom tabletopsurface surface
Hide thumbs Also See for Signal Management Solutions PNP515 Series:

Advertisement

Quick Links

PNP515
PNP515
PNP515
PNP515
Series
Series
Series
Series
Welcome!
We greatly appreciate your purchase of the PNP515/517/527/537/547
Customizable Pop 'N Plug (PNP) with Custom Tabletop Surface. We are sure
you will find it reliable and simple to use. Superior performance for the right
price, backed by solid technical and customer support is what ALTINEX has to
offer.
We are committed to providing our customers with Signal Management
®
Solutions
to the most demanding audiovisual installations at competitive
pricing and we welcome you to join the ranks of our many satisfied customers
throughout the world.
1. Precautions and Safety Warnings
Please read this manual carefully before using your PNP Interconnect Box.
Keep this manual handy for future reference. These safety instructions are to
ensure the long life of your PNP and to prevent fire and shock hazards. Please
read them carefully and heed all warnings.
1.1 General
Qualified ALTINEX service personnel or their authorized representatives
must perform all service.
Unauthorized personnel shall not open the unit since there are
high-voltage components inside
1.2 Installation Precautions
For best results, place the PNP in a dry area away from dust and
moisture.
To prevent fire or shock, do not expose this unit to water or moisture.
Do not place the PNP in direct sunlight, near heaters or heat-radiating
appliances, or near any liquid. Exposure to direct sunlight, smoke, or
steam can harm internal components.
Handle the unit carefully. Dropping or jarring can cause damage.
Never place fingers inside the openings of the unit. This action could
cause serious injury due to sharp edges inside the unit.
Do not place heavy objects on top of the PNP. Do not use excessive force
to push down on the top of the unit.
2. Installation Procedures
Step 1.
Refer to the ALTINEX website, www.altinex.com, to download the latest templates and instructions for tabletop cutting requirements and installation
instructions.
In order to do this, locate the PNP on the website and go to its detail page. The links to the templates, user's guide, and more are on the left hand side
of the screen.
Step 2.
Print all information applicable to the installation of the PNP, including the templates and any detailed installation instructions.
Step 3.
Cut an opening into the table's surface. The cutout is the top of the PNP, so it must be cleanly cut and saved. This operation should be performed by
experienced professionals in order to insure accuracy and to be aesthetically pleasing.
Note: Always confirm dimensions before cutting to insure that specifications have not changed.
Step 4.
Install the PNP into the table per the installation instructions provided on the website.
Step 5.
Connect all cables to their appropriate sources and/or destinations. The PNP is now ready for operation.
3. Limited Warranty/Return Policies
Please see the ALTINEX website at
400-0464-005
Customizable Pop 'N Plug
Customizable Pop
Customizable Pop
Customizable Pop
'N Plug
'N Plug
'N Plug
www.altinex.com
for details on warranty and return policies.
®
with Custom Tabletop
with Custom Tabletop
with Custom Tabletop
with Custom Tabletop
To turn off the main power, disconnect the power cord. The power
outlet should be near the equipment and easily accessible.
ALTINEX recommends using wall outlets with a Ground Fault Circuit
Interrupter (GFCI) for maximum protection.
Install all cables according to the instructions. Do not force or pull any
cable or power cord attached to the PNP.
1.3 Cleaning
Surfaces should be cleaned with a dry cloth. Never use strong detergents
or solvents such as alcohol or thinner. Do not use a wet cloth or water to
clean the unit.
1.4 FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions found herein, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by
ALTINEX, Inc. could void the user's authority to operate the equipment.
1
User's Guide
Surface
Surface
Surface
Surface

Advertisement

loading
Need help?

Need help?

Do you have a question about the Signal Management Solutions PNP515 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altinex Signal Management Solutions PNP515 Series

  • Page 1 2. Installation Procedures Step 1. Refer to the ALTINEX website, www.altinex.com, to download the latest templates and instructions for tabletop cutting requirements and installation instructions. In order to do this, locate the PNP on the website and go to its detail page. The links to the templates, user’s guide, and more are on the left hand side of the screen.
  • Page 2 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description Mechanical Inputs (F) / Outputs (M) PNP517 Min. Table Thickness 0.750 in (19 mm) AC Power NEMA 5-15 (8) Max. Table Thickness 1.125 in (29 mm)
  • Page 3 NOTE: One side of the PNP517 connector installation is shown in the above diagram. The PNP517 has another of the same sectional plates facing the opposite side of the table. Various combinations of connectors, along with the applicable cable types, may be selected for customization at the time of purchase. Please, refer to the ALTINEX website (www.altinex.com) for specific customization options and instructions. 400-0464-005...
  • Page 4 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide 6. Application Diagrams Diagram 1: Typical Setup for PNP517 REVERSE SIDE OF PNP517 Notebook Computer PNP517* Notebook Computer Notebook Computer Floor box Notebook Computer The PNP517 is shown as in the above diagram. The PNP517 is a standard configuration that includes the PNP515 and two DS901-130 standard faceplates.
  • Page 5 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 2: Typical Setup for PNP527 REVERSE SIDE OF PNP527 PNP527 Notebook Computer Notebook Computer Floor box The PNP527 is shown as in the above diagram. The PNP527 is a standard configuration that includes the PNP515 and two DS901-122 standard faceplates.
  • Page 6 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 3: Typical Setup for PNP537 REVERSE SIDE OF PNP537 PNP537 Notebook Computer Notebook Computer Floor box The PNP537 is shown as in the above diagram. The PNP537 is a standard configuration that includes the PNP515 and two DS901-123 standard faceplates.
  • Page 7 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 4: Typical Setup for PNP547 REVERSE SIDE OF PNP547 PNP547 Notebook Computer Notebook Computer Floor box The PNP547 is shown as in the above diagram. The PNP547 is a standard configuration that includes the PNP515 and two DS901-124 standard faceplates.
  • Page 8 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 5: Cutout Dimensions 5.650" 5.450" [144 mm] [138 mm] 5.850" 5.650" [149 mm] [144 mm] Diagram 6: Closed Dimensions 9 3 4 '' [248 mm] 8 3 4 '' [222 mm] 400-0464-005...
  • Page 9 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 7: Front View Dimensions TABLE THICKNESS MIN. 3/4'' [19 mm] MAX. 1 1/8'' [29 mm] 5 1/10'' [130 mm] 6 1/10'' [155 mm] FRONT VIEW 6 1 8 '' [156 mm] 400-0464-005...
  • Page 10 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 8: Side View Dimensions SIDE VIEW 14 7 [378 mm] 9 3 4 '' [248 mm] 8 1 2 '' [216 mm] 400-0464-005...
  • Page 11 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 9: Standard Plates US & UK DS901-130 DS901-131 Standard on PNP517 for United States. PNP517C with configurable snap-ins. DS901-122 DS901-125 Standard on PNP527 for United Kingdom. PNP527C with configurable snap-ins. 400-0464-005...
  • Page 12 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 PNP515/517/527/537/547 User’s Guide Diagram 10: Standard Plates AU & GR DS901-123 DS901-122 Standard on PNP537 for Australia. PNP537C with configurable snap-ins. DS901-124 DS901-127 Standard on PNP547 for Germany. PNP547C with configurable snap-ins. 400-0464-005...
  • Page 13 Make sure that no cable or power cord is damaged or pinched. If until needed again. there has been damage to the unit, do not use the PNP. Please contact ALTINEX at (714) 990-2300 to have the unit repaired. 7.2 Power/Signal Connections Connect external devices to the appropriate connector on the PNP.