TABLE OF CONTENTS EC REGULATIONS AND SECURITY SAFETY INSTRUCTIONS SYSTEM DESCRIPTION CONTROLS AHLINK MICROPHONE INSTALLATION AHNET PROTOCOLS INFORMATION ON DISPOSAL WARRANTY TERMS AND CONDITIONS...
Page 4
WELCOME Thank you for purchasing an ARTHUR HOLM product. Our product range has been designed for a seamless integration and for a maximum reliability. Please, read this installation and operating instructions carefully and keep them in a safe place for future reference.
Page 5
ABOUT US The Company Arthur Holm has its origins in the Danish furniture designer Jorgen Alex Jensen, who was active during the sixties and the seventies. His design inspiration and his concept of ergonomics have been continued by his family, who is the design force behind Arthur Holm product range. The...
EC REGULATIONS AND SECURITY ATTENTION: Do not disassemble or modify the device in any way. This symbol warns of the presence of dangerous un-insulated voltages inside some of the components, of sufficient magnitude to expose people to risk of electronic shock. This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit.
Page 7
SAFETY INSTRUCTIONS Wiring connected to hazardous voltage requires installation by qualified personnel or the use of ready-made flexible cables. For your security, your equipment must be connected to an elec- trical outlet with grounding connection protection. Since the plug is used to disconnect the device, the operating electrical outlet must be in an easily accessible place.
Integrated wireless set-up and diagnosis. The Arthur Holm dynamicTalkB microphone lift is designed to hide boundary microphones when not in use with a smooth, elegant and silent movement.
CONTROLS Controller Board AHnet: PoE Connector Use the power supply to connect the device. Connect an Ethernet CAT6 shielded cable to the output on the power supply and then connect the CAT cable AHnet connector to the microphone lift. For remote control using the AHnet, connect a CAT6 shielded cable to the input on the power supply and then connect the cable to the network.
AHLINK AHlink is used to control and set-up the unit. By default, the AHlink signal on the unit is deactivated. To activate the AHlink signal, press for 5 seconds the external Up and Down screen buttons located on the cover plate, or press for 5 seconds the UP and Down contact close on the GPI connector.
Page 11
AHLINK If the device does not appear on the window, the AHlink signal is not active. The AHlink name always begins with AH characters and the fourth last MAC AHlink address. Select the device to control and set-up the unit. When selecting the device, the first page will upload on the mobile phone.
Page 12
AHLINK SERIAL Serial number of the unit Firmware version Controls the Up and Down screen movements DISP: Turns the display ON or OFF DVIA, DVI1, DVI2: Input source selection BACKL: Configuration of the display's backlight CONTR: Configuration of the display's contrast BRIGHT: Configuration of the display's brightness...
Page 13
AHLINK SERIAL: Device serial number information IP[1]: First network IP number IP[2]: Second network IP number IP[3]: Third network IP number IP[4]: Fourth network IP number AUT. CLOSE PORT: Controls the automatic close 2002 port when there is no traffic information during 5 minutes MASK[1]: First network MASK number MASK[2]: Second network MASK number...
MICROPHONE INSTALLATION Remove the 3 screws placed in the center of the bottom of the microphone. Plug the network cable into the microphone and guide it through the center exit path. When the cable is secured, guide it through the tube (anchor piece).
Page 15
MICROPHONE INSTALLATION Assemble the microphone by introducing it vertically (matching the hole of detail A) and turning it 90º clockwise.. To remove the microphone pull the microphone slightly upwards and turn it 90º anticlockwise. Now the microphone can be extracted vertically.
AHNET PROTOCOL Communications protocol COMMUNICATION RS422 CONNECTION RJ45 WIRING CAT-5 Speed and configuration BAUD RATE 38400 DATA BITS PARITY NONE STOP BITS Wiring Diagram 1. Data TX + 2. Data TX – 3. Data RX + 4. NC 5. NC 6 .Data RX RJ-45 7.
Page 17
AHNET PROTOCOL AHnet protocol Use the Bluetooth connection to find the device IP. Factory IP address is 192.168.0.128. To send AHnet commands open port 2002, send AHnet command and close port. Using 5 bytes communication: BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE...
INFORMATION ON DISPOSAL FOR USERS OF WASTE ELECTRICAL & ELECTRONIC EQUIPMENT This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to the designated collection points, where they will be accepted on a free of charge basis.
WARRANTY TERMS AND CONDITIONS Albiral Display Solutions warrants this product against manufacturing defects and workmanship for a period of two (2) years from the date of purchase, subject to the conditions below. 1. Electrical, electronic boards, engine, mechanical parts, accessories and power supply are warranted against manufacturing defects and workmanship for a period of two (2) years from the date ot purchase.
Need help?
Do you have a question about the DYNAMICTALKB and is the answer not in the manual?
Questions and answers