HEATING SEQUENCE OF OPERATION
CONTINUED
FLAME SIGNAL ABOVE
( > 1.40 microamps)
I
SINGLE-STAGE
THERMOSTAT
MODE
I
'L
(DiP SWITCH SET AT 'SINGLE")
I'
YES _
START SECOND-STAGE
RECOGNITION
ON DELAY (10 OR 15 MINUTES).
STATUS LED -- HEARTBEAT
ROLLOUT SWITCHES CLOSED?
YES
I
FIRST-STAGE
(LOW FIRE)
PRESSURE
SWITCH CLOSED?
YES _l
_ NO
FIRST-STAGE
HEAT DEMAND SATISFIED?
YES _
GAS VALVE OFF, COMBUSTION
AIR INDUCER
OFF FOLLOWING
POST PURGE.
INDOOR BLOWER OFF WITH DELAY
STATUS LED -- PULSE
SECOND-STAGE
30-SECOND
DELAY ON BEGINSJ
STATUS LED -- HEARTBEAT.
YES _
SECOND-STAGE
COMBUSTION
AIR INDUCER
ON. SECOND-STAGE
GAS VALVE ON. HIGH
HEAT INDOOR BLOWER SPEED ON.
STATUS LED -- HEARTBEAT.
q
SECOND-STAGE
HEAT DEMAND.
SECOND-STAGE
HEAT DEMAND REQUIRED?
YES _
t
SECOND STAGE PRESSURE
SWITCH CLOSED?
ABNORMAL
FLASH CODE.
NOTE - IF SECOND-STAGE
PRESSURE
SWITCH
WAS ORIGINALLY FOUND CLOSED,
ABNORMAL
CODE WILL FLASH.
NO _ I
YES _
YES
SECOND-STAGE
PRESSURE
SWITCH CLOSED
IN LESS THAN TEN (10) SECONDS?
STATUS LED -- HEARTBEAT
YES _
CONTINUED ON NEXT PAGE
THERMOSTAT
CALLS FOR HEAT.
STATUS LED -- HEARTBEAT
SEE BOX A.
LOW FLAME SIGNAL
(Does not affect control operation)
STATUS ERROR CODE 1 + 2.
,
I
I TWO STAGE THERMOSTAT
MODE
I_
I.
(DIP SWITCH SET AT "TWO")
j
YES _
I 45-SECOND
INDOOR BLOWER ON DELAY BEGINS.
STATUS LED -- HEARTBEAT.
YES _
_,
PRIMARY & SECONDARY
LIMIT SWITCHES
CLOSED?
GAS VALVE OFF. COMBUSTION
AIR INDUCER ON.
INDOOR BLOWER ON.
STATUS ERROR CODE 5 + 1. SEQUENCE
HOLDS
UNTIL ROLLOUT SWITCH IS RESET AND MAIN
POWER IS INTERRUPTED
OR THERMOSTAT
IS CYCLED OFF/ON FOR 3 SECOND MINIMUM.
k-
F
I GAS VALVE OFF, COMBUSTION
AIR INDUCER OFF,
INDOOR BLOWER ON.
STATUS ERROR CODE 3 + 1.
I
HAS PRIMARY OR SECONDARY
LIMIT
SWITCH CLOSED WITHIN 3 MINUTES?
(Indoor blower on low speed during 3-minute period
NO 1,
I
LIMIT SWITCH WATCHGUARD
MODE.
I
GAS VALVE OFF, COMBUSTION
AIR INDUCER OFF,
INDOOR BLOWER OFF WITH DELAY
LY..ES_
STATUS ERROR CODE 4 + 5
IS 60-MINUTE
RESET PERIOD COMPLETE?
|
GAS VALVE OFF. COMBUSTION
AIR INDUCER ON.
INDOOR BLOWER OFF AFTER DELAY.
STATUS ERROR CODE 2 + 3. CONTROL RESTARTS
IGNITION SEQUENCE
IF PRESSURE
SWITCH
CLOSES WITHIN 2-1/2 MINUTES.
SECOND-STAGE
PRESSURE
SWITCH CLOSED
AT BEGINNING
OF HEAT DEMAND?
STATUS ERROR CODE 2 + 6.
YES
._.o
I
SECOND STAGE HEAT DEMAND
STATUS LED -- HEARTBEAT.
No f
RETURNS TO FIRST-STAGE
HEAT MODE WHICH
CONTINUES
UNTIL SECOND-STAGE
PRESSURE
SWITCH CAN BE PROVEN or HEAT DEMAND IS
SATISFIED. FIVE (5) MINUTE WAIT PERIOD
INITIATED BEFORE RETRY. WERE 5 ATTEMPTS
MADE FOR SECOND-STAGE
HEAT?
YES _
CONTINUES
FIRST-STAGE
HEATING DEMAND.
WILL NOT REATTEMPT
SECOND-STAGE
HEATING DEMAND,
STATUS ERROR CODE 2 + 5.