ADCP-50-304 • Issue 19 • June 1999 • Section 6: Installation
RSP
CMD
SEL
CTL
1.6
Control Module DIP Switch Settings
When PatchSwitch equipment is configured for serial remote control, the chassis address must
be selected on each control module. For dc pulse control, the chassis address is ignored. Each
CM contains a four-position DIP switch to identify its chassis address. Bit positions 1 through 4
on the DIP switch are set to an identifying address assigned to that chassis during the
installation of the PS chassis system.
Caution: Make certain that each chassis on a communications channel is assigned a different
(unique) identifying address in the range of 0 through 15 (000
Page 6-4
© 1999, ADC Telecommunications, Inc.
DCE/DTE BERG
POST FOR DSR
JUMPER
BERG
STRAP
U3
U5
U4
Figure 6-2. Data Converter Module
DIP
SOCKET
U1
DTE
U2
DCE
U6
PROGRAMMING
PLUG
1635-A
through 1111
).
2
2