  • Page 1 Linc inst v2.1...
  • Page 2: General Information

    LINCOLN These products have been designed to the highest standard with safety and strength in mind. Follow the recommendations in this guide to ensure maximum benefits from your Lincoln bath. GENERAL INFORMATION READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING THE PRODUCT. IF YOU HAVE ANY QUESTIONS CALL YOUR LOCAL SUPPLIER.
  • Page 3: Safety Instructions

    RESPONSIBILITY OF THE INSTALLER THE INSTALLER MUST INSPECT THE PRODUCT PRIOR TO INSTALLATION TO ENSURE THE UNIT IS FREE OF DEFECT OR DAMAGE. IN THE EVENT OF A PROBLEM, THE UNIT MUST NOT BE INSTALLED. IF THE PACKAGING OR PRODUCT HAS BEEN DAMAGED, PLEASE CALL YOUR LOCAL SUPPLIER IMMEDIATELY.
  • Page 4: Cleaning Information

    If this unit is to be utilized by many different bathers, we would strongly recommend that it is cleaned regularly with a medical disinfectant. CLEANING INFORMATION The Lincoln bath does not require any major maintenance, but you should follow these simple instructions. To clean the bath correctly the backrest & footrest must be removed.
  • Page 5: Technical Data

    Platform in the cleaning position (Fig 9) Fig 8 Fig 9 WARNING DO NOT RAISE THE BATH WITH THE PLATFORM IN THE UPRIGHT POSITION AS THIS WILL DAMAGE THE BATH & PLATFORM The bath should be wiped down, preferably whilst the bath is draining, with a soft, damp cloth. To retain the surface quality of the bath, clean weekly using bathroom cleaning mousse or washing-up liquid.
  • Page 6 Typical amp 24v at full load 3amps Battery backup system Maximum patient weight 26stone (165kg) Unit weight empty 185kg Water volume Maximum weight of bath, patient & water Suitable for intermittent use only – 2 minutes on – 18 minutes off Hot water controlled by thermostatic TMV 3 valve 1 800 INSTALLATION INSTRUCTIONS...
  • Page 7 Unit weight empty 185kg Maximum user weight 26stone (165kg) Electrical supply 230V -50-60Hz – refer to label Switched fuse spur rated 5 Amp RCCB rated 30mA System operating voltage 24 volt Typical amp 24v at full load 3 amps Preparation of Site Carefully remove all packaging and inspect bath thoroughly.
  • Page 8 The 40mm flexible waste kit supplied must be connected to the waste trap & to the drain provided. Please discuss temperature setting with the customer before setting the valve to confirm their preference for bathing temperature, taking into account local regulations. See Addendum at back of this pack for setting TMV.
  • Page 9 Final Checks Operate the bath controls to make sure the unit functions correctly the bath raises & lowers ok check all cables are not snagging with any items & the water pipes are not snagging. Check all plumbing connections for leaks. Check the water outlet temperature from the bath taps is 43°C.
  • Page 10 Fig 12 Fig 13 TMV 3 valve Control box Earth lead Wheels Transportation bars POWERED BATH INSTALLATION KIT Contents:- M6 x 70 Coach Screws Qty 8 Fixing foot brackets to floor 6 x 30 Nylon Plugs Qty 8 Fixing foot brackets to floor WARRANTY INFORMATION This product is warranted as being free from defects during the period of warranty.
  • Page 11 The warranty covers manufacturing defects in the products, starting from the date of manufacture. Contact your Supplier to find out more about the warranty period. The warranty is limited to the value of the purchase price paid. The warranty is only valid if the product has been used correctly. Where there are any mechanical or electrical parts, any damage, misuse or tampering with them will render the warranty invalid.
  • Page 12 Linc inst v2.1...
  • Page 13 Linc inst v2.1...
  • Page 14 ‘T’ Cut or Brasso.  Lincoln - The 4 x rods holding the platform should be cleaned using a silicone-based furniture polish. (i.e. Mr. Sheen.) Please do not use wax-based products. Also carry out a visual inspection of the seals around the rods for signs of damage.
  • Page 15  Ensure that the tap and waste fittings are all working correctly and that the seat fixings are all in good order.  Check condition and operation of the handset control. Ensure your bath is serviced regularly. Please ask for details of the Gainsborough Bathrooms Ltd. Service and Maintenance Agreement. Gainsborough Bathrooms...