1. CONNECT WIRING

Remove wiring cover.
Run power cable to installation location, remove knockout
from rough-in plate wiring box and connect cable to wiring
box using proper connector. Connect black to black,
white to white, and green or bare wire under second
ground screw. Replace wiring cover.
Blower plate
2. INSTALL BLOWER PLATE
Attach blower plate to the studs at the inside, top of
hood with (4) #10-24 nuts, provided.
Blower plate
7" round

3. INSTALL DUCTWORK

Run 7" round steel duct to installation location.
Connect duct to rough-in plate. Use duct tape to make all
joints secure and air tight.
Duct tape
Blower plate
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
Black to Black
White to White
Green to Green
or Bare Wire or
under ground
screw
Inside, top
of hood
#10-24 nuts
(2 per side)
Inside, top
of hood
7" Round duct
Outside, top of hood

4. INSTALL BLOWER

Hang blower onto blower plate. Engage (2) barrel nuts
into small ends of keyholes. Tighten barrel nuts and wing
nut securely.