Rear downdrafts – Professional
Recommended Ventilator Kits
Model
Number
of Filters
Interior
30" W. VIPR101(R)SS
2
VIDV500
36" W. VIPR161(R)SS
2
VIDV500
48" W. VIPR181(R)SS
2
VIDV500
Rear downdrafts – Designer
Recommended Ventilator Kits
Model
Number
of Filters
Interior
30" W. DIPR100RSS
2
VIDV500
36" W. DIPR160RSS
2
VIDV500
45" W. DIPR150RSS
2
VIDV500
R E A R D O W N D R A F T S
Recommended Duct Size
Maximum Amps
Exterior
Interior
Exterior
Interior
Exterior
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
R E A R D O W N D R A F T S
Recommended Duct Size
Maximum Amps
Exterior
Interior
Exterior
Interior
Exterior
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
VEDV900/VEDV1200
10"
10"
4.0
6.0
(can transition
to 6" round)
36
Ventilator kits – Professional and Designer
W A L L A N D I S L A N D H O O D S
Interior
Ventilators
VIV300
DIV440
VIV600
DIV880
VIV1200
Model
DIV300
DIV600
DIV1200
300
440
600
880
APPROXIMATE CFM
1
See Specifications
RECOMMENDED
DUCT SIZE
50 ft. (15.2 m)
MAXIMUM DUCT RUN
2
See Specifications
MAXIMUM AMPS
All 18" high rangehood ventilator kits include rough-in kit, transition to round duct (7" round for VIV600 – all other 10" round), and damper (if applicable).
All ventilator kits use 120VAC/60Hz.
Proper installation is extremely important to ensure maximum performance from any ventilation product.
1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated.
2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
• Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 5-10 feet (1.52-3.05 m) of straight run.
• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirements, if any.
Requirements for Designer hoods installed over Professional
cooking products with char-grill feature
Designer hoods can be installed over Professional cooking products. However, when choosing a Professional range or rangetop with the
gas char-grill feature, the following ventilator kits must be used to ensure proper performance:
D E S I G N E R H O O D S *
30", 33", 36", 39", 42", and 45" wide hoods – Classic Chimney models and
Built-in Custom Ventilator Systems as noted below
36" and 42" wide hoods – Tall Traditional models as noted below
48" wide hoods – Tall Traditional models as noted below
48" and 51" wide hoods – Classic Chimney models and Built-in Custom
Ventilator Systems as noted below
Includes the following wall hoods: Classic Chimney, Classic Chimney with Ledge, Classic Chimney Ledgeless, Built-in Custom Ventilation Systems (for wall hoods),
*
Tall Traditional with Ledge, and Tall Traditional Ledgeless. (Slim Traditional wall hoods, Box wall hoods, Classic Chimney island hoods, and Island Custom Ventilator Systems
should not be installed over Professional ranges and rangetops with the gas char-grill feature.)
D O W N D R A F T S
Exterior
Interior
Exterior
Ventilators
Ventilators
Ventilators
VEV900
VEV1200
VEV1500
VIDV500
VEDV900 VEDV1200
DEV900
DEV1200
DEV1500
1,200
900
1,200
1,500
500
900
1,200
3 1/4"x10"
10" round
(can transition
to 6" round)*
75 ft.(22.8 m) 40 ft.(12.1 m)
4.0
6.0
V E N T I L A T O R K I T
(when used over ranges/rangetops with char-grill)
1,200 CFM exterior ventilator kit (DEV1200)
1,200 CFM interior or exterior ventilator kit (VIV1200 or VEV1200)
1,200 CFM interior or exterior ventilator kit (VIV1200 or VEV1200)
or 1,500 CFM exterior ventilator kit (VEV1500)
1,200 CFM interior or exterior ventilator kit (DIV1200 or DEV1200)
or 1,500 CFM exterior ventilator kit (DEV1500)
37

Advertisement