FES BATTERY PACK GEN2 14S, Version 1.23
Note: Before using the charger, check if the fuse on the grid is suitable.
For 1200W charger it should be minimum 10A fuse.
For 2300W charger it should be minimum 16A fuse.
High power chargers must be connected directly to inlet, without extension
cables and splitters.
Warning: If you have another pair of Battery pack, make sure that you do
not mix packs between the two sets. The same two packs of one set (first
marked as A, second marked as B) must be always used in pair!

3.2 Standard charger to Battery pack connection and charging

Caution: Place charger on a safe, secure position. Keep away from dust, direct
sunlight, fire, smoke, childrens and any unatendent person!
Warning: Before charging, physical condition inspection of the battery packs
should be done. Any sign of mechanical damage, such as a puncture, dents,
scratches, must be evaluated and reported to manufacturer before charging.
1. Connect RED + and BLUE - cables from charger to first battery pack.
2. Connect charger and Battery pack with BMS-Charger communication cable.
BMS-Charger communication cable (KOP601, KOP1001)
Page 10 of 26
September 2019