Important - Please Read And Follow; General Information; Built-In Installation; Electrical Connection - Viking VRBD/VUBD 24" W Use & Installation Manual

24” w. beverage dispenser
Table of Contents

Advertisement

IMPORTANT - PLEASE READ AND FOLLOW

•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•The installer should leave these instructions with the consumer for future reference.

GENERAL INFORMATION

1. ALWAYS connect CO2 gas cylinder to reducing valve or regulator
2. NEVER connect gas cylinder directly to keg.
3. ALWAYS secure gas cylinder in upright position.
4. ALWAYS keep gas cylinder away from heat.
5. NEVER drop or throw gas cylinder.
6. ALWAYS ventilate after CO2 leakage.
7. Gas cylinders should be stored in the coolest part of the room, preferably at 70
upright position before the primary regulator is attached to the cylinder
CO
CAN BE DANGEROUS
2
If it becomes difficult to breathe and
your head starts to ache, abnormal
concentrations of carbon dioxide may
be present in the area. Leave the
room immediately.
BEER DISPENSING KIT CONSISTS OF:
•Draft Tower Assembly
•Drain Hose
•Drain Container
•Keg Coupler
•Air Line with Clamps
•Single Gauge Regulator
•Filled 5 lb. CO 2 Cylinder
TOOLS NEEDED:
•Crescent Wrench
•Pliers
•Screwdriver
F., and securely fastened in the
o
Draft Tower
Assy
Regulator
Keg Coupler
Pressure
(Sankey type
Gauge
shown)
Beer Line
Air
Line
Toggle Shut
Off Valve
2
Proper Disposal of Your Old Refrigeration Product
Suffocation Hazard
Remove doors from your old
refrigerator.
Failure to do so can result in
child entrapment, which can
cause death or brain damage
IMPORTANT: Child entrapment and suffocation are not problems of
the past. Junked or abandoned refrigerators are still dangerous, even
if they will sit for "just a few days." If you are getting rid of your
refrigeration product, please follow the instructions below to help
prevent accidents.
BEFORE YOU THROW AWAY YOUR OLD REFRIGERATION
PRODUCT:
•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.

BUILT-IN INSTALLATION

Select Location
The proper location will ensure peak performance of your appliance. Choose a location where the unit will be out of
direct sunlight and away from heat sources. Units with fan cooled condensers can be built-in.
Unit should be operated in a properly ventilated area with ambient temperatures above 40 o F (4.4 o C) and below
Regulator
110 o F (43 o C). Installation should be such that the cabinet can be moved for servicing if necessary.
Coupling Nut
Cabinet Clearance
Drum Valve
Ventilation is required from the bottom front section of the unit. Keep this area open and clear of any obstructions.
The adjacent cabinets and countertop can be built around the unit as long as no top trim or counter top is installed
lower than the top of the hinge.
Set Screw

ELECTRICAL CONNECTION

Electrical Requirements
A 115 volt, 60 Hz, AC only 15 amp fused electrical supply is required. (A
time delay fuse or circuit breaker is recommended.) It is recommended
CO 2 Tank
that a separate circuit, serving only this appliance, be provided.
•ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
•DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER
SUPPLY CORD GROUND PLUG.
•DO NOT USE AN EXTENSION CORD.
Recommended Grounding Methods
For your personal safety, this unit must be grounded. This appliance is equipped with
a power supply cord having a 3-prong grounding plug. To minimize possible shock
hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle
grounded in accordance with the National Electrical Code and local codes and
ordinances.
If the circuit does not have a grounding type receptacle, it is the
responsibility and obligation of the customer to exchange the existing receptacle in
accordance with the National Electrical Code and applicable local codes and
ordinances. The third ground plug SHOULD NOT, under any circumstances, be cut or
removed. All UL listed refrigerated products are equipped with this type of plug.
Grounding type wall
Power Supply
receptacle
with 3-prong
grounding plug
Electrical Shock Hazard
Do not splash or spray water
from a hose on a refrigerated
unit. Doing so may cause an
electrical shock which may
result in severe injury or death.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

VrbdVubd

Table of Contents