AccuRelief ACRL-9100 User Manual

AccuRelief ACRL-9100 User Manual

Wireless 3-in-1 pain relief device
Hide thumbs Also See for ACRL-9100:

Advertisement

Wireless 3-in-1
Pain Relief Device
User Manual
Model ACRL-9100

Advertisement

Table of Contents
loading

Summary of Contents for AccuRelief ACRL-9100

  • Page 1 Wireless 3-in-1 Pain Relief Device User Manual Model ACRL-9100...
  • Page 2 This manual is valid for the Wireless 3-in-1 Pain Relief Device ACRL-9100 This instruction manual is published Carex Health Brands Carex Health Brands reserves the right to improve and amend it at any time without prior notice. Amendments may however be published in new editions of this manual.
  • Page 3: Table Of Contents

    TABLE OF CONTENS Introduction ..........................4 Important safety precautions and warnings .................5 How TENS works for pain relief....................12 How EMS works for muscle stimulation..................13 Package contents........................14 Know your device........................15 Charging...........................18 Easy steps to get started with your therapy with electrode pads..........Cleaning and storage........................26 Specifications...........................28 How to control and reduce your pain..................30...
  • Page 4: Introduction

    INTRODUCTION Thank you for purchasing the Wireless 3-in-1 EMS: The device is designed to be used to Pain Relief Device ACRL-9100 for your pain stimulate healthy muscles in order to improve and facilitate muscle performance. relief solution. It should be applied to normal, healthy, dry and In order to use the stimulator safely, read the clean skin of adult patients.
  • Page 5: Important Safety Precautions And Warnings

    IMPORTANT SAFETY PRECAUTIONS AND WARNINGS It is important that you read all the warning and precautions included in this manual because they are intended to keep you safe, prevent injury and avoid a situation that could result in damage to the device.
  • Page 6 WARNING DO NOT USE ON THESE INDIVIDUALS DO NOT USE THIS DEVICE UNDER Pregnant women, because the safety of THESE CONDITIONS: electrical stimulation during pregnancy has not Consult with your physician before using this been established. device, because the device may cause lethal Children or infants, because the device has not rhythm disturbances in certain susceptible been evaluated for pediatric use.
  • Page 7 Pads should not touch each other when placed WARNING onto your skin. PAIN MANAGEMENT WARNINGS Pads must be placed at least 2 in apart. If you have had medical or physical treatment for your pain, consult with your physician before DANGER using this device.
  • Page 8 If you have suspected or diagnosed heart disease, The pads are already pre-gelled and will you should follow precautions recommended by adhere to your skin. your physician. To avoid damage to the adhesive surface of If you have suspected or diagnosed epilepsy, the pads, put the pads only on the skin or on you should follow precautions recommended the plastic film provided.
  • Page 9 Pad should not touch any metal object, such as a Dispose of the device, batteries, and components belt buckle or necklace. according to applicable legal regulations. Unlawful disposal may cause environmental pollution. Do not share pads with another person. This may cause a skin irritation or infection.
  • Page 10 TENS is not a substitute for pain medications Keep unit away from young children. The unit contains small pieces that may be and other pain management therapies. swallowed. Contact your physician TENS devices do not cure disease or injuries. immediately if ingested. TENS is a symptomatic treatment and, as such, Use this device only with the electrodes and suppresses the sensation of pain that would...
  • Page 11 CAUTION: Possible Adverse Reactions Do not use to treat one region for extended periods of time (more than 30 minutes a session, up to 3 times/day) or muscles in that region may become exhausted and sore. You may experience skin irritation and burns beneath the stimulation electrodes applied to your skin.
  • Page 12: How Tens Works For Pain Relief

    What is it? How TENS works? Scientific theory suggests that electrical stimulation The Wireless 3-in-1 Pain Relief Device ACRL-9100 is a single output channel TENS machine and highly therapy may work in several ways: effective in temporarily relieving pain. TENS therapy...
  • Page 13: How Ems Works For Muscle Stimulation

    HOW EMS WORKS FOR MUSCLE STIMULATION The goal of electrical muscle stimulation is to What is it? achieve contractions or vibrations in the muscles. EMS works by sending electronic pulses to the Normal muscular activity is controlled by the central muscle needing treatment;...
  • Page 14: Package Contents

    The session will be TENS recorded in the History folder of the app. RECHARGEABLE PROGRAMS TURN ON THE ACRL-9100 MASSAGE LITHIUM BATTARY To turn off, press the power button on UNIT AND START A SESSION the app or device. Remove the electrodes from the skin.
  • Page 15: Know Your Device

    KNOW YOUR DEVICE Features 1. On/off button [ ]: Press this button to turn on the device or turn off the device. Channels: One channel Green Flashing indicator light: The device hasn't Treatment modes TENS: 6 programs connected with APP or the Remote Controller; EMS: 5 programs Continuous green: The device is in standby MASSAGE: 3 programs...
  • Page 16 LCD DISPLAY Intensity decrease Intensity increase Treatment proqram Power select: Neck/ ON/OFF Shoulder/Arm/ button LBack/Joint/Leg Mode select Tap/Knead/Rub (TENS/EMS/ MASSAGE)
  • Page 17 LCD Display Treatment mode Lock Icon Treatment time icon Intensity icon Low battry icon Treatment time display Treatment intensity display Treatment program...
  • Page 18: Charging

    If the charge is not complete at the Micro-USB cable into the Micro-USB beginning of a program, the battery may become charging port of the ACRL-9100 device, depleted before the end of the session. You and then connect to the Standard cannot use the device while it is charging.
  • Page 19: Easy Steps To Get Started With Your Therapy With Electrode Pads

    EASY STEPS TO GET STARTED WITH YOUR THERAPY WITH ELECTRODE PADS STEP 4 Using the APP to control main device: Step 3– Preparation of the ACRL-9100 unit Step 1 Downloading the APP Each gel pad is pre-fixed with a Download the application to your smart phone :...
  • Page 20 WARNING: WARNING: Make sure the device is turned off before applying electrodes. Note: Always connect the device before you place the electrodes on the skin. WARNING: Place the electrode pads Note: DO NOT place the electrodes on top of each according to the electrode Pad placement other or so close to each other that they touch each illustrations, on pages 22-23.
  • Page 21 Pad Placement illustrations Position of the electrodes-TENS programs: LOWER BACK NECK / CERVICAL PAIN Attach both pads on the lower Attach both pads on the neck. back with the backbone in the DO NOT place on the back of DO NOT place on the the carotid artery, throat or the center.
  • Page 22 KNEE / JOINT PAIN Attach both pads above the knee or above and below the joint with pain. CALF PAIN Attach both pads on the calf/leg where you DO NOT place electrode pads feel pain. simultaneously to the calves of both legs. ANKLE / FOOT PAIN Attach pads per the illustration on the left for pain on the outside of your ankle/foot.
  • Page 23 On a scale of 1 to 10, evaluate the intensity connection is activated on your of the pain. For no pain press 0, for smartphone or tablet. Turn on ACRL-9100 extremely intense pain press 10. the APP. Press the on/off button on the...
  • Page 24 1. Remove the battery cover on the back of the device 2. Insert 2xAAA batteries. Make sure the positive + and negative – signs correspond with the markings Step 3– Preparation of the ACRL-9100 unit in the device when inserting batteries. Reinstall the Please refer to pg.19 battery cover .
  • Page 25 STEP 6 - Turn off the device You can turn device off in the following ways: NOTE: You cannot turn the ACRL-9100 unit on by pressing the remote control. You must do so by The device will turn off automatically after 30 ■...
  • Page 26: Cleaning And Storage

    CLEANING AND STORAGE Cleaning the main device and the remote control 4) Dry the pads and let the adhesive surface air-dry 1) Turn unit off. Remove USB if device has been completely (do not wipe with a tissue paper or cloth). charging.
  • Page 27 Use of electrodes that are much smaller than the electrodes provided with the KEEP DEVICE AND ALL ACCESSORIES ACRL-9100 may increase the chance of skin irritation OUT OF REACH OF CHILDREN. or electrode burns occurring under the electrodes.
  • Page 28: Specifications

    SPECIFICATIONS Power Sources: 3.7V Li-ion (remote Weight: 36g (main device) control : DC 3.0V 2 x AAA Batteries ) 65g (Remote control) Power Supply:5V DC, 300mA Service life of the device: 2 years Frequency: 2Hz~150Hz Service life of electrode pads: 30 times Pulse Width: 50us~370us Applied part: Electrode Wave form: Biphasic square wave...
  • Page 29 APP’s connection request passively, establishing a one-on-one RF Frequency 2.4GHZ-2.48GHZ connection with the APP. After the ACRL-9100 Channel Bandwidth 2 M H z (-20db) device connects to the APP, the device will not be Operation Voltage DC3.7V...
  • Page 30: How To Control And Reduce Your Pain

    HOW TO CONTROL AND REDUCE YOUR PAIN When should the device be used? How long should you use the device? Always turn unit Use as soon as your pain begins. Start with one Start with one 30 minute session. off with pads still on. session (unit automatically turns off at 30 minutes).
  • Page 31 Recommended treatment session as following: What type of pain is it best for? You may use the device for 30 minutes a day. This therapy works best on acute pain because You may need to use it for longer (maximum 3 it is localized.
  • Page 32: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSES POSSIBLE SOLUTION Are the batteries exhausted? Replace the batteries. The unit will not power on Are the batteries installed correctly? Insert the batteries observing polarity. Electrodes are dried out or dirty. Replace with new electrodes. Stimulation weak or cannot feel any Electrodes do not stick to skin well.
  • Page 33 PROBLEM POSSIBLE CAUSES POSSIBLE SOLUTION Improper electrode placement. Reposition electrode. Stimulation is ineffective. Unknown Contact clinician. Reposition the electrodes. If at any time you feel pain or Using electrodes on the same site every time. discomfort, stop use immediately. Electrodes are not adhered to the skin properly. Ensure the electrodes are securely adhered to the skin.
  • Page 34: Product/Battery Disposal

    Type BF Applied Part PRODUCT/BATTERY DISPOSAL Refer to instruction manual Used fully discharged batteries must be disposed of in a specially labeled collection The first number 2: Protected against container, at toxic waste collection points or solid foreign objects of 12,5 mm Ф through an electrical retailer.
  • Page 35: Important Information Regarding Electromagnetic Compatibility (Emc)

    Guidance and manufacture’s declaration – electromagnetic emission The ACRL-9100 is intended for use in the electromagnetic environment specified below. The user of the ACRL-9100 should assure that it is used in such an environment. Emission test Electromagnetic environment – guidance...
  • Page 36 IEC 61000-3-3 Guidance and manufacture’s declaration – electromagnetic immunity The ACRL-9100 is intended for use in the electromagnetic environment specified below. The user of ACRL-9100 should assure that it is used in such an environment. Electromagnetic Immunity test IEC 60601 test level...
  • Page 37 UT) for 25 cycles UT) for 25 cycles interruptions, it is recommended <5% UT (>95% dip <5% UT (>95% dip that the ACRL-9100 be powered in UT) for 5 sec in UT) for 5 sec from an uninterruptible power supply or a battery.
  • Page 38 Guidance and manufacture’s declaration – electromagnetic immunity The ACRL-9100 is intended for use in the electromagnetic environment specified below. The user of the ACRL-9100 should assure that it is used in such an environment. Immunity test IEC 60601 test level...
  • Page 39 Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.b Interference may occur in the...
  • Page 40 RF communications equipment and the ACRL-9100 The ACRL-9100 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ACRL-9100 can help prevent electromagnetic interference by...
  • Page 41 Separation distance according to frequency of transmitter (m) Rated maximum output power of transmitter 150 KHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz d= 1.2 d = 1.2 d = 2.3 0.01 0.12 0.12 0.23 0.38 0.38...
  • Page 42: Fcc Compliance Information

    FCC Compliance information If this equipment does cause harmful interference Caution: The user is cautioned that changes or to radio or television reception, which can be modifications not expressly approved by the party determined by turning the equipment off and on, responsible for compliance could void the user's the user is encouraged to try to correct the authority to operate the equipment.
  • Page 43: Warranty

    WARRANTY Damage during transport from the Please contact Carex Health Brands in case of a claim under the warranty. If you have to send in the unit, enclose a copy manufacturer to the consumer or during of your receipt and clearly state the defect. The following transport to the retailer.
  • Page 44 Manufactured for: Carex Health Brands Middleburg Heights, OH 44130 A division of Compass Health Brands Tel: 800-328-2935 customerservice@carex.com Copyright 2017 by Carex Health Brands...