10 INSTALLATION

Flexible Connector Hookup

Pressure
regulator
Adapter
/
" or
/
"
1
3
2
4
Gas pipe
Installer: Inform the consumer of the location of the
gas shut-off valve.
Gas Flow into Cooktop
Flex connector
(6 ft. max.)
Adapter
Gas shut-off valve

Electrical Connections

Electrical Requirements
127 Volt, 60 Hertz, properly grounded dedicated
circuit protected by a 15 A or 20 A circuit breaker or
time delay fuse.
Grounding
IMPORTANT: FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance should be equipped
with a three-prong (grounding) plug which mates with
a standard three-prong grounding wall receptacle to
reduce the possibility of electric shock hazard from
this appliance.
The customer should have the wall receptacle and
circuit checked by a qualified technician to be sure
the receptacle is properly grounded.
When connecting the cord of this cooktop to a
standard two-prong wall receptacle, it is the personal
responsibility and obligation of the customer to have
it replaced with a properly grounded three-prong wall
receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD.
A word about Ground Fault Circuit Interrupters –
Ground Fault Circuit Interrupters are not required or
recommended for gas cooktop receptacles.
Ground Fault Circuit Interrupters are devices that
sense leakage of current in a circuit and automatically
switch off power when a threshold leakage level is
detected. These devices must be manually reset by
the customer.
Performance of the cooktop will not be affected if it
is operated from a Ground Fault Circuit Interrupters
protected circuit but occasional nuisance can occur.
Preferred
Method
CAUTION
The customer should have the circuit checked by
a qualified technician to make sure the receptacle
is correctly grounded.
Ensure proper ground
exists before use