Download Print this page
Honeywell GENT S4-INTERFACE-PROG User Manual

Honeywell GENT S4-INTERFACE-PROG User Manual

Interface programmer kit

Advertisement

Quick Links

User guide
S4 Interface Programmer Kit
(S4-INTERFACE-PROG) V1.04
Cable assembly
Programmer
AC-DC Adaptor
Model MCPLG6V10WUK
Input: 230Vac 47-63Hz 0.3A
Output: 6V
1.33A
The kit (S4-INTERFACE-PROG)
can be used to program the
S4-Interface units to simulate
legacy 344XX range of interface
units. This allows the
S4 interface units to be used in
place of old interfaces without the
need to upgrade or re-commission
the system.
Setting the rotary switches
The Programmer has four rotary
switches to set interface channels.
Rotary switches
Channel 4
Channel 2
Channel 3
Channel 1
4188-982 issue 5-3_10-13_S4 Interface progkit
Set the rotary switches on the Programmer to the required number or letter for
each interface Input/Output channel(s).
Rotary switch settings on the Programmer
Rotary
Switch
position Function
0
Unused
1
Relay Output (N/O) or
Sector Output
(Normally Off)
2
Relay Output (N/C) or
Sector Output
(Normally On)
3
N/C Fire Input
4
N/O Fire Input
5
N/C Fault Input
6
N/O Fault Input
7
N/C Supervisory Input No delay
8
N/O Supervisory Input No delay
9
N/C Fire Input
A
N/O Fire Input
B
N/C Fault Input
C
N/O Fault Input
D
N/C Supervisory Input 10s delay
E
N/O Supervisory Input 10s delay
F
Zone Input -
S4-34450 and
S4-34410 (channel 1
only)
N/C - Normally Closed N/O - Normally Open
! - check if delay of 10s can be applied, the old product has a fixed delay of 30s.
P - applicable option
# - only channel 1 is configurable, channels not used set to - UNUSED
~ - 34450 with 19245-06 PSU used for mains switching
A converted interface unit can be installed in an analogue addressable panel
based system:
BS panel having - MCC ³ V3.70 and LPC ³ V3.81
EN panel having - MCC ³ V4.10 and LPC ³ V4.11
by Honeywell
To convert a S4-Interface to a
344XX interface:
to a
3
3
3
4
4
4
4
4
4
Applied
1
1
4
delay
5
0
0
#
#
P P
P P
P
P
P
No delay
P
P
No delay
P
P
No delay
P
P
No delay
P
P
P
P
!
P
10s delay
!
P
10s delay
P
!
10s delay
!
P
10s delay
!
P
P
!
P P P
3
Link
3
setting
4
4
applicable
4
4
to
5
5
S4-34450
0 ~
0
only
P
P
P
P
P
P
!
!
!
!
!
!
1

Advertisement

loading

Summary of Contents for Honeywell GENT S4-INTERFACE-PROG

  • Page 1 User guide S4 Interface Programmer Kit by Honeywell (S4-INTERFACE-PROG) V1.04 Set the rotary switches on the Programmer to the required number or letter for each interface Input/Output channel(s). To convert a S4-Interface to a 344XX interface: Rotary switch settings on the Programmer...
  • Page 2 User guide S4 Interface Programmer kit Plug the S4-34450/S4-34410 Interface Instructions to convert S4-34450 or S4-34410 Unit into the terminal blocks on the LV Interface units Programmer . Connect the AC-DC These procedures must be followed to convert a S4-34450 LV Adaptor lead to the power socket Interface unit to a legacy 34450 4-channel interface unit or a S4-34410 the Programmer and the other end to a...
  • Page 3 S4 Interface Programmer kit User guide Disconnect the cable assembly from the Instructions to convert a S4-34440-02 Mains powered loop pins of the programmed S4-34440-02 Interface unit Mains powered interface PCB. Disconnect the battery lead from connector P7 on the These procedures must be followed to convert a S4-34440-02 Mains PCB and remove the batteries and leads powered interface to a legacy 34440 Mains powered interface unit.
  • Page 4 Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes.