Replacing Other Manufacturers' Time Controls
Refer to Honeywell for wiring conversion diagrams.
Completion Checklist for Installation
1. Check unit powers up correctly, and that the display does not remain blank.
2. Set Zone 1 and Zone 2 operating modes to AUTO and switch Zone 1 and Zone 2 on and off using the OVERRIDE buttons, to ensure the system
is operating correctly.
3. Check the factory-set day, date, and time are correct and adjust if necessary. Refer to the User Guide for details.
4. If required, enter Installer Mode and adjust Installer Parameters to match the lifestyle and needs of the User. Remember to make a note of these
parameter changes in the Configuration Data section of the User Guide. Also note here how the zones have been set.
5. Explain the operation of the product to the User and help them to set their Zone 1 and Zone 2 programmes. There are 3 built-in profiles that can
be used as a basis for typical User programmes.
6. If required, attach the self-adhesive programme guide label to the underside of the cover flap. The label is supplied in the box and requires to be
peeled away from the backing material before use. Write details of how the zones have been configured in the space provided.
7. Explain when the User should contact someone to arrange a Service Visit.
8. Write the date of installation, your name and telephone number in the space provided in the User Guide, in the section 'Boiler & System Service
Log'
9. Remember to leave the User Guide and Installation Instructions with the User and remind them to keep them in a safe place. This forms part of a
Home Information Pack.
This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries
and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered
designs, registered trade marks, unregistered trade marks and copyrights.
Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only
applicable to the product(s) described.
This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance.
Honeywell cannot be held responsible for misapplication of the product(s) described within this document.
Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sarl, Ecublens, Route du Bois 37, Switzerland by its
Authorised Representative Honeywell Inc.
Honeywell Control Systems Ltd.
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
50022736-007 A
www.honeywelluk.com
© 2007 Honeywell International Inc.
4
ST9500C 2-Zone Programmer

INSTALLATION INSTRUCTIONS

Introduction
ST9500 is an Electronic Programmer which provides accurate time
control for central heating systems with separate 7 day programmes for
two independent heating zones.
ST9500 Programmers can be combined with other Honeywell controls such
as Room Thermostats, Cylinder Thermostats, Wiring Centres and Zone or
Diverting Valves to form a fully automatic central heating control system.
Mounting
The Programmer should be mounted at a level where the display can be
seen clearly, (1.2 to1.5m from the floor) and the ambient temperature is
within the range of 0 to 40°C. The ST9500 is for use in normal domestic
environments.
CAUTION
Isolate power supply and make safe before wiring the unit to prevent
electric shock and equipment damage. Installation should be carried
out by a qualified electrician or competent heating engineer.
To remove the unit from the wall-plate, slacken the two securing screws at
the bottom of the ST9500 and hinge the unit up to separate the two halves.
Wiring
Final Assembly
Clip the unit onto the hinges on the top of the wallplate and hinge down
into position. Tighten the two securing screws using a screwdriver.
Switch on the power – the unit will now be operating according to the
built-in programme. Note : the ST9500 is supplied with a factory set
clock for faster installation .
Refer to ST9500 User Guide for programming details.
Specification
Power Supply: 230V~, 50...60Hz, 10W
Switch Action: 2 x SPDT
Switch Rating: 230V~, 50...60Hz, 3(3)A
Factory set clock
Power Reserve: lifetime battery
Programmes/Settings: permanently stored in NV RAM
Approvals: Conforms to protection requirements of
Directives 2006/95EC and 89/336EC
Mounting Options
RECOMMENDED CLEARANCE DISTANCES:
ABOVE WALLPLATE:
BELOW WALLPLATE:
LEFT/RIGHT OF WALLPLATE:
a. Surface mounting
concealed wiring
b. Flush switchbox
Fixing holes are
spaced to suit BS4662
requirements
c. Surface mounting with
surface wiring in
mini trunking
Ensure the mounting surface is supporting and fully covers the wiring
wall-plate.
ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E. REGULATIONS.
THIS UNIT IS FOR FIXED WIRING ONLY.
A switch, having contact separation of at least 3mm in all poles (formerly
Class 'A'), must be incorporated in the fixed wiring as a means of
disconnecting the supply.
The unit is a Class II (double insulated) device. A parking terminal is
provided for external earth continuity.
The system must be appropriately fused. A fuse rated at no more than
3 Amps should be installed.
The unit has 4 knockouts for surface wiring, care must be taken to ensure
that the cable or mini-trunking completely fills the knockout hole without
leaving any gaps.
110mm
100mm
10mm
1

Advertisement

loading

Summary of Contents for Honeywell ST9500C

  • Page 1: Installation Instructions

    This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. The unit is a Class II (double insulated) device. A parking terminal is Honeywell cannot be held responsible for misapplication of the product(s) described within this document.