Read these instructions for use carefully and keep them for later ENGLISH use, be sure to make them accessible to other users and observe the information they contain. Table of contents Signs and symbols 1. Getting to know your device ..............3 2.
4 x adhesive electrodes (45 x 45 mm) The CE labelling certifies that the product complies with the essential requirements of Directive 93/42/EEC on medical 3 x AAA batteries products. Manufacturer 1. Getting to know your device What is a digital EMS/TENS unit and what can it The device can emit effective output values above 10 mA, averaged over every five-second interval Digital EMS/TENS units fall into the electrostimulation device...
TENS, or transcutaneous electrical nerve stimulation, relates • Muscle training to support the strengthening of specific muscles to the electrical stimulation of the nerves via the skin. TENS is or muscle groups, and to achieve the desired changes to physical an effective non-pharmacological method of treating different proportions types of pain that have a variety of causes.
Page 5
• If you use an insulin pump Before using the device, consult your doctor if any of the • If you have a high temperature (e.g. > 39°C) following applies to you: • If you have a known or acute cardiac arrhythmia, or disorders of •...
Page 6
• For hygiene reasons, the electrodes may only be used on one • Treatment of the skin with moisturising lotions or ointments person. beforehand is not recommended as this considerably increases • If the device does not work properly, or you feel unwell or the electrode wear and may cause unpleasant current peaks.
Display (full screen): • Choking hazard! Small children may swallow and choke on 1 Menu batteries. Store the batteries out of the reach of small children. 2 Program number • Observe the plus (+) and minus (-) polarity signs. 3 Impulse intensity channel 2 ( •...
5. Use intensity in the display changes accordingly. If the program is in a pause phase, the intensity cannot be increased. 5.1 Notes on use • The device switches itself off automatically if it is not used for General information one minute (automatic switch-off).
6. Program overview 6.2 EMS program table The digital EMS/TENS unit features a total of over 70 programs: Progr. Area of application, indications Running time Possible • 15 TENS programs (min) electrode positions • 35 EMS programs Warming up 1-27 •...
6.3 MASSAGE program table Progr. Area of application, indications Running time Possible (min) electrode Progr. Area of application, indications Running Possible positions time (min) electrode Tightening the shoulder muscles positions Strengthening the lower back muscles 4-11 Tapping massage 1 Maximising the strength of the lower back 4-11 Tapping massage 2 muscles...
It is fundamental to the intended success of electrostimulation electrodes of a channel so that the area affected by the pain applications that electrodes are positioned sensibly. is between the electrodes or to position one electrode directly We recommend that you consult your doctor to establish the ideal on the area affected by the pain and the other electrode at a electrode positions for your intended application area.
Page 13
˄/˅ 1. Place the electrodes on the desired area for treatment (for 3. Use the setting buttons to select the impulse frequency you positioning suggestions see electrode positions in section 6.4) want and use the ENTER button to confirm. ˄/˅ and connect them to the device.
˄/˅ working time and pause time for this program to between 1 and 30 3. Use the setting buttons to select the working time ("on seconds each. time") you want and use the ENTER button to confirm. ˄/˅ 4. Use the setting buttons to select the pause time ("off time") 1.
Deletion of the Doctor’s function is confirmed with a long acoustic more easily to lower impulse frequencies up to 15 Hz, whereas fast- signal. reacting fibres only respond from approximately 35 Hz onwards. Impulses of approx. 45 – 70 Hz are linked with constant tension in Therapy memory the muscles and quicker fatigue.
10. Cleaning and storage electronics retailers. You are legally required to dispose of the batteries. Adhesive electrodes Note: The codes below are printed on • To ensure that the adhesive electrodes remain adhesive for as batteries containing harmful substances: long as possible, clean them carefully with a damp, lint-free cloth Pb = Battery contains lead, Cd = Battery contains or clean the underside of the electrodes under lukewarm, running cadmium, Hg = Battery contains mercury.
Please note that portable and 14. Technical specifications mobile HF communication systems may interfere with this unit. Name and model EM 49 More details can be requested from the stated Customer Services Type EM 49 address or found at the end of the instructions for use.
The following warranty terms shall apply: for medical products, as well as those of the Medizinproduktegesetz 1. The warranty period for BEURER products is either 5 years or- if (German Medical Devices Act). longer- the country specific warranty period from date of Purchase.
Need help?
Do you have a question about the EM 49 and is the answer not in the manual?
Questions and answers
Добрый день.Мне нужно узнать частота импульса форма импульса