Compressive Limbs Therapy Compressive limbs therapy is able to promote a right venous circulation by decreasing muscle tension caused by stress or chronic and acute pains: thanks to its pump action it favorites venous return by increasing tissues blood circulation and finally their physiological renewal.
Specifications Power Q-6000 has the following specifications: • Class IIa equipment (Directive 93/42/EEC, annexed IX, rule 9); • Class I, applied part type BF (Classif. CEI EN 60601-1); • Equipment not protected against liquids penetration; • Equipment and accessories not subjected to sterilization; •...
Page 8
Insert the pressure plantars under the feet (available only with double leggings); iii) When wearing the leggings pay attention to position the tubes connection cables in the internal side of each legging; iv) Connect 6 tubes to the 6 plugs positioned on each legging, paying attention to connect the longer tube to the higher position connector of legging (thigh);...
Page 9
Wear the armband and connect the tubes to the armband plugs, paying attention to connect the longer tube to the higher position connector on armband; After connecting the tubes to the armband connect the tubes to the air discharge output. 3) Pressure regulator (selector on machine body) Air pressure in compression chambers can be adjusted from 0 to maximum pressure (around 217 mmHg ±...
Troubleshooting Problem Solution • Power Q-6000 Check the connection to the domestic plug doesn’t switch on • Check the ON/OFF button • Check the power supply status (no sign of damages) • Power Q-6000 emits Check if there are any damages and/or holes a strange sound like in the tubes and connectors air leakage...
Warnings The following warnings guarantee user safety and prevention against damages and/or lesions. Please read it carefully before using Power Q-6000 Warning Caution In case of not following the In case of not following the instructions the user may instructions the user may suffer from injuries or device suffer from serious injuries damages...
Page 12
Do not exceed 20 minutes in the first Do not use the device if you feel pain or treatments. We suggest to start with bad feelings. treatments of 5/10 minutes Attention do not spill liquids or any Use only in consenting adults substances on the device.
Page 13
Caution Do not move when the device is working. Do not expose the device to the sun and do not storage it next to heat sources Do not place any objects on the device or If you not use the device for a long time or on its parts (connector tubes, applicators, if you use the device in cold places, a etc.)
Maintenance, carriage and storage If it is used in accordance with the instructions of the user manual, the device does not need a particular regular maintenance. Carriage precautions It doesn’t need any particular carriage precautions: however we recommend to put away Power Q-6000 and its accessories in their own box after every treatment.
Spare parts Contact the distributor or the fabricant for original spare parts at following address: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a • 30030 Martellago (VE) Tel. +39 0415401356 • Fax +39 0415402684 www.iacer.it • iacer@iacer.it To preserve product warranty, functionality and product safety we recommend to use only original spare parts.