These menus are available by scrolling with the UP/DOWN
Button.
Push SELECT Button to enter the selected menu.
6.3.1.

LANGUAGE setting

Select «LANGUAGE» :
- Scroll the proposed languages with UP/DOWN buttons
- Press the SELECT Button to validate choice
6.3.2.

DATE/HOUR setting

Select «DATE/HOUR»
- Scroll years YYYY with UP/DOWN buttons. Then
validate with SELECT button
- Scroll months MM with UP/DOWN buttons. Then
validate with SELECT button
- Scroll days DD with UP/DOWN buttons. Then validate
with SELECT button
- Scroll hours HH with UP/DOWN buttons. Then validate
with SELECT button
- Scroll minutes MM with UP/DOWN buttons. Then
validate with SELECT button
- Press SELECT button to validate EXIT from this setting
6.3.3.

RESET Overload

Select «RESET OVERLOAD»
- Select YES to restart Storelio off-grid with UP/DOWN
buttons
- Press SELECT button to validate
Storelio off-grid will restart the system. Wait for the following
message:
STORELIO ES3015
OFF-GRID HH:MM
If the load shedding is not sufficient, the system
will not restart properly, and « OVERLOAD »
message will appear.
Turn off more devices and reset the system again.
6.3.4.

Exit setting

Select EXIT
Push SELECT button to exit menu, and come back to the
main display.
Version v1.0 – February 15, 2015
7. BATTERY
PROTECTION
To prevent the battery from over-discharging, Storelio off-
grid will automatically shut down. Screen will not be
powered. This is a normal protective state in order to avoid
over-discharge.
To restart the system, check:
- if the DC wires are not damaged and if the PV switch is
ON
- if there is enough solar energy to recharge the battery
properly.
Then do the following steps:
- Access the DC compartment
- Turn OFF the battery switch. The PV switch must be
turned ON.
- Push the "WK UP" button for at least 4 seconds, until
the screen turns up.
Commissioning will start. Follow the displayed messages.
See chapter COMMISSIONING.
.
8.

DECOMMISSIONING

Storelio off-grid decommissioning must be
conducted by qualified installer.
DANGER!
Make sure that all 230V sources are turned off.
DANGER!
Disconnect the PV array by turning OFF the
external PV switch.
Follow the described steps :
- Turn OFF the AC IN breaker
- Turn OFF the AC OUT breaker
- Access the DC compartment and turn OFF the PV and
battery switches
- Push the « WK UP » button for at least 15 seconds, until
the screen turns off.
DANGER!
The PV wires are always energized. Voltage from
PV panels can be as high as 150V.
In case of re-commission, it is needed to wait at
least for 30 seconds before restarting.