Coleman CO534L-A Owner's Manual page 14

Table of Contents

Advertisement

12
Jet Operation
One Pump Systems
CO518R, CO534L
Single pump systems operate on high power only.
To operate the jets, press the JETS button:
Once to turn the pump ON.
Twice to turn the pump OFF.
Two pump systems
CO756B, CO756L
Press the Jets 1 button:
Once to turn the pump ON.
Twice to turn the pump OFF.
Press the Jets 2 button:
Once to activate low speed pump.
Twice to activate high speed.
Three times to turn pump off.
Heater Light
The heater light will turn on whenever the heater is
operating. It will appear three different ways when
the spa is operating:
A steady light means that the spa is operating at
220V.
A slowly blinking light means that the spa is operating
at 120V.
A rapidly fl ashing light means that the heater
is reading the water temperature. When the
temperature has been determined, the heater light
will stop fl ashing. You will frequently see the heater
light fl ashing rapidly while it is also steady or slowly
blinking.
Coleman logo (white)
<----------
Low and High Power Operation
Two and three pump systems can be confi gured to
operate on low or high power. The factory default
is low power. This section describes how the
spa operates when it is confi gured for low power
operation.
See page 5 for GFCI and wiring requirements for
both low and high power operation.
JETS
Spas confi gured for low power operation require
approximately 20% less power to operate. With low
power confi guration, the spa will never use more
JETS 1
than 30 amps while in operation and will alternate
JETS
between 110V and 220V, while spas confi gured for
high power will operate continuously at 220V.
JETS
JETS 2
When only one pump is running, the heater will
JETS 1
operate at 220V. When two or three pumps are
running, the heater will automatically switch to op-
JETS 1
erate at 110V.
JETS 3
JETS 2
The heater light will tell you when it is operating
and what voltage it is using. See the "Heater Light"
JETS 2
section above.
MODE
JETS 3
For spas confi gured for high power operation, the
heater will turn on when (1) the water temperature
JETS 3
drops or (2) the jets are in use.
MODE
MODE
Coleman
Spas (online sales)
®
LTR50001135, Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Co-628t-aCo-637l-aCo-756b-aCo-756l-aCo-756b-sCo-756l-s

Table of Contents