IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
WARNING – This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise touching this product.
INSTALLATION INSTRUCTIONS:
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, MAKE CERTAIN THAT THE POWER SUPPLY IS OFF
BEFORE INSTALLING OR SERVICING THIS FIXTURE.
Make sure to read and fully understand these instructions before attempting to install this product.
1. Before the ceiling is finished, run the appropriate line voltage
(and dimming control wiring if applicable) to the approximate
location where the AB2 fixture will be installed.
2. After the ceiling material is installed and finished, make the
ceiling cutout using a 2-7/8" hole saw to cut an opening for
the AB2 downlight. Because of the small reflector flange on
the AB2, the accuracy of this hole is critical. Even a 3" hole
saw may leave a ceiling cutout too large to be completely
hidden after installation.
3. Pull the wiring (installed earlier) below the ceiling, slide the
J-tube cover open (keeping it on the conduit) and connect
the wiring to the J-tube through the open 1/2" knockout. A
3/8" flex conduit duplex connector may be used to easily
daisy-chain the fixtures together. For single installations and
end-of-run applications, a standard 1/2" knockout connector
can be used.
Because the AB2 features dimming capability, be sure to
make any low voltage wiring connections in this step. When
wiring for dimming, the low voltage wiring installs through
the adjoining 1/2" knockout. A second 3/8" flex conduit duplex
connector may be used in this knockout where applicable.
4. After the appropriate connections have been made, simply
slide the J-tube closed until it locks in place with the spring on
opposite ends of the assembly.
WARNING: Do not pinch wires between J-Tube cover
and endplates!
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY INSTALLED WIRING ON THE FIXTURE. SAFETY
AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
701 Millennium Blvd • Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright
2017 12/26/17
,
AB2LED
KEEP THESE INSTALLATION INSTRUCTIONS!
revision, All Rights Reserved - Printed in U.S.A.
Part
No...........................................93084892
Fig. 1
2-7/8" HOLE SAW
Fig. 2
Fig. 3
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Prescolite AB2LED and is the answer not in the manual?

Questions and answers

Summary of Contents for Hubbell Prescolite AB2LED

  • Page 1 Part No...........93084892 Page 1 of 6 IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker.
  • Page 2 Part No........... 93084892 Page 2 of 6 5. Feed the wired J-tube assembly through the ceiling cutout. The J-tube assembly has been designed to conveniently lie on top of the ceiling material. (NOTE: This fixture is designed for use in a non-insulated ceiling.) (Fig.
  • Page 3 Part No........... 93084892 Page 3 of 6 Primary Reflector Removal and Installation Primary Reflector Removal The primary reflector on the AB2 is designed to be easily replaced. To remove the primary reflector, first remove the lower trim (see step 6 on installation instructions).
  • Page 4 Nº de la pièce......... 93084892 Page 4 of 6 IMPORTANTES INFORMATIONS SUR LA SÉCURITÉ. LISEZ ET RESPECTEZ TOUTES LES CONSIGNES DE SÉCURITÉ. Lisez les informations et suivez les consignes sur l'étiquette relativement aux emplacements mouillés ou humides, à l'installation à proximité de matériaux combustibles, à l'isolation, aux matériaux de construction et aux ampoules appropriées.
  • Page 5 Nº de la pièce......... 93084892 Page 5 of 6 5. Faire passer l’ensemble du tube en J branché à travers la découpe du plafond. L’ensemble du tube en J a été conçu pour reposer de manière pratique sur le dessus du matériau du plafond. (REMARQUE : luminaire est conçu pour une utilisation sur un plafond non isolé.) (Fig.
  • Page 6 Nº de la pièce......... 93084892 Page 6 of 6 Retrait et installation du réflecteur primaire Retrait du réflecteur primaire Le réflecteur primaire de l’AB2 est conçu pour être facilement remplacé. Pour retirer le réflecteur primaire, retirer d’abord la garniture inférieure (voir l’étape directives...

Table of Contents