Fan Kit; Fan Removal Instructions - Irving IRHEDV32 Installation Instructions & Homeowner's Manual

Direct vent insert
Table of Contents

Advertisement

DAMPER
FLUE COLLAR
UNIT
DAMPER
FRONT FRAME
UNIT
FLUE COLLAR PLATE
MAKE SURE THE FLUE COLLAR PLATE IS IN
CONTACT WITH THE BACK EDGE OF THE CABINET TOP
PLATE FLUE COLLAR
10003929
3" FLEX VENT
TWO PIECES
CLAMPS & SCREW
FASTENER
PLATE
GASKET
PLATE
FIG.2
Fig. 8
3" CHIMNEY LINER
TWO PIECES
CLAMPS & SCREW
FLUE COLLAR PLATE
FIG.3
Fig. 9
FASTENER PLATE
CABINET TOP
MOVE
BACK
FIG .4
Fig. 10
FASTENER PLATE
CABINET TOP
FIG.5
MACHINE SCREW AFTER
FASTENED
Fig. 11

FAN KIT

115 volt, 60 Hz.56W
The fan kit includes the following: fan, temperature sensor,
speed control and a 6 ft. cord. The following explains how
to start and set the fan for automatic operation.
1. Plug in the electrical cord.
2. Start gas fire - see lighting procedures.
3. Turn on fan speed control.
4. Wait until the unit has warmed up sufficiently to
activate the termperature sensor, approximately
5-10 minutes.
5. Once fan starts, adjust speed control to desired fan
speed. The fan will now automatically come on
every time the fireplace is in operation. Should the
fan not be needed simply turn off the speed control.
The appliance, when installed must be elec-
trically connected and grounded in accord-
ance with local codes or, in the absence of
local codes, with the current CSA C22.1
Canadian electrical code.
For U.S.A. Installations, follow local codes
and the National Electrical code, ANSI/
NFPA No. 70.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement
components see Fig. 13.

FAN REMOVAL INSTRUCTIONS

1. Turn off gas and electricity.
2. Remove the front glass.
3. Remove the logs.
CAUTION: LOGS MAY BE HOT
4. Remove burner assembly and rear log support plate.
5. Remove the fan mounting nuts (2 nuts). (Fig. 12)
6. Slip off the electrical connector at the motor.
7. Lift out the fan.
8. To reinstall reverse procedure.
Thermal sensor
is attached
to burner base
screw studs
Fan speed control/
TOP VIEW
Junction box
A: SPEED CONTROL
B: TEMPERATURE SENSOR
C: FAN
A
Black
White
Ground
Fan is installed
at the back of
the air intake box
Valve
Fig. 12
C
B
Fig. 13
8